Configuration
Configuration and Calibration Sequence
Display Shows | Action/Explanation |
| |
Label Positioning Parameters | |
BACKFEED | Press SELECT to make change. |
| Backfeed Sequence: Press PLUS (+) or MINUS |
| display other choices. |
| Default: Default (90%) |
| Selections: Default, after, before, 10%, 20%, 30%, 40%, |
| 50%, 60%, 70%, 80%, off |
| Press SELECT to accept the change. |
| This parameter establishes when and how much label |
| backfeed occurs after a label is removed or cut in the peel- |
| off or cutter modes. It has no effect in rewind or |
| modes. This parameter setting can be superseded by the ~JS |
| instruction when received as part of a label format (see the |
| ZPL II Programming Guide Volume I). |
| The difference between the value entered and 100% |
| establishes how much backfeed occurs before the next label |
| is printed. For example, a value of 40 means that 40% of the |
| backfeed takes place after the label is removed or cut. The |
| remaining 60% takes place before the next label is printed. A |
| value of “before” means that all backfeed takes place before |
| the next label is printed. |
LABEL TOP | Press SELECT to make change. |
MINUS
Default: +0
Range:
Press SELECT to accept the change.
The label top position adjusts the print position vertically on the label. Positive numbers adjust the label top position further down the label (away from the printhead); negative numbers adjust the position up the label (toward the printhead).
78 | Z4Mplus and Z6Mplus User Guide |