Configuration

Configuration and Calibration Sequence

Display Shows

Action/Explanation

 

 

Selecting Prefix and Delimiter Characters

Prefix and delimiter characters are 2-digit hex values used within the ZPL/ZPL II formats sent to the printer. The printer uses the last prefix and delimiter characters sent to it, whether from a ZPL II instruction or from the front panel.

DO NOT use the same hex value for the control, format, and delimiter character. The printer needs to see different characters to function properly.

CONTROL PREFIX

Press SELECT to make change.

 

Control Prefix Character: Press MINUS () to move to

 

the next digit position, press PLUS (+) to increase the value

 

of the digit.

 

Default: 7E (tilde - displayed as a black square)

 

Range: 00 to FF

 

Press SELECT to accept the change.

 

The printer looks for this 2-digit hex character to indicate the

 

start of a ZPL/ZPL II control instruction.

FORMAT PREFIX

Press SELECT to make change.

 

Format Prefix Character: Press MINUS () to move to the

 

next digit position, press PLUS (+) to increase the value of

 

the digit.

 

Default: 5E (caret)

 

Range: 00 to FF

 

Press SELECT to accept the change.

 

The printer looks for this 2-digit hex character to indicate the

 

start of a ZPL/ZPL II format instruction.

 

 