Configuration
Configuration and Calibration Sequence
Display Shows | Action/Explanation |
|
|
Media and Ribbon Sensor Calibration
Performing the manual calibration procedure resets the sensitivity of the sensors to detect the media and ribbon you are using more accurately. With the sensors at their new sensitivity, the printer then performs the manual calibration. Changing the type of ribbon and/or media may require resetting the sensitivity of the media and ribbon sensors.
SENSOR PROFILE | Press SELECT to make change. |
| Sensor Profile: Press PLUS (+) to print a media sensor |
| profile. |
| The media sensor profile may be used to troubleshoot |
| registration problems that may be caused when the media |
| sensor detects preprinted areas on the media or experiences |
| difficulty in determining web location. If the sensitivity of |
| the media and/or ribbon sensors MUST be adjusted, use the |
| manual calibration procedure. |
MEDIA AND RIBBON | Press SELECT to display MEDIA AND RIBBON |
| CALIBRATE. |
| Manual Calibration: Press PLUS (+) to start the |
| calibration procedure. |
| This procedure is used to reset the sensitivity of the media |
| and ribbon sensors. The manual calibration is then |
| performed. |
LOAD BACKiNG | Open the printhead. |
| Remove approximately 8 in. (200 mm) of labels from the |
| media roll, enough so that only the liner material is threaded |
| between the media sensors when the media is loaded. |
| Close the printhead. |
| To cancel the operation, press MINUS |
REMOVE RiBBON | Open the printhead. |
| Remove the ribbon (sliding it as far to the right as possible |
| has the same effect as removing it). |
| Close the printhead. |
| To cancel the operation, press MINUS |
|
|
Z4Mplus and Z6Mplus User Guide | 69 |