ZyXEL Communications metrogigabit switch manual Resetting the Switch Via the Console Port

Models: metrogigabit switch

1 448
Download 448 pages 49.97 Kb
Page 54
Image 54

Chapter 4 The Web Configurator

previous configurations and the speed of the console port will be reset to the default of 9600bps with 8 data bit, no parity, one stop bit and flow control set to none. The password will also be reset to “1234” and the IP address to 192.168.1.1.

To upload the configuration file, do the following:

1Connect to the console port using a computer with terminal emulation software.

2Disconnect and reconnect the Switch’s power to begin a session. When you reconnect the Switch’s power, you will see the initial screen.

3When you see the message “Press any key to enter Debug Mode within 3 seconds ...” press any key to enter debug mode.

4Type atlc after the “Enter Debug Mode” message.

5Wait for the “Starting XMODEM upload” message before activating XMODEM upload on your terminal.

6After a configuration file upload, type atgo to restart the Switch.

Figure 20 Resetting the Switch: Via the Console Port

Bootbase Version: V1.00 06/28/2010 17:49:40

RAM: Size = 65536 Kbytes

DRAM POST: Testing: 65536K

OK

DRAM Test SUCCESS !

FLASH: AMD 128M *1

ZyNOS Version: V3.90(BVO.0)b3 07/23/2010 18:43:25

Press any key to enter debug mode within 3 seconds.

........................

Enter Debug Mode ras> atlc

Starting XMODEM upload (CRC mode)....

CCCCCCCCCCCCCCCC

Total 393216 bytes received. Erasing..

................................................................

OK

ras> atgo

The Switch is now reinitialized with a default configuration file including the default password of “1234”.

54

MGS3700-12C User’s Guide

Page 54
Image 54
ZyXEL Communications metrogigabit switch manual Resetting the Switch Via the Console Port