The ZyXEL Device will send traps to the SNMP manager when any one of the following events occurs:
Table 98 | SNMP Traps |
| |
|
|
|
|
| TRAP # | TRAP NAME | DESCRIPTION |
|
|
|
|
| 0 | coldStart (defined in | A trap is sent after booting (power on). |
|
|
|
|
| 1 | warmStart (defined in | A trap is sent after booting (software reboot). |
|
|
|
|
| 4 | authenticationFailure (defined in | A trap is sent to the manager when receiving any |
|
| SNMP get or set requirements with the wrong | |
|
|
| community (password). |
| 6 | whyReboot (defined in ZYXEL- | A trap is sent with the reason of restart before |
|
| MIB) | rebooting when the system is going to restart (warm |
|
|
| start). |
| 6a | For intentional reboot: | A trap is sent with the message "System reboot by |
|
|
| user!" if reboot is done intentionally, (for example, |
|
|
| download new files, CI command "sys reboot", etc.). |
| 6b | For fatal error: | A trap is sent with the message of the fatal code if the |
|
|
| system reboots because of fatal errors. |
To change your ZyXEL Device’s SNMP settings, click Advanced > Remote MGMT > SNMP. The screen appears as shown.
Use this screen to control SNMP access to your ZyXEL Device. To access this screen, click Management > Remote MGMT > SNMP.
224 | Chapter 18 Remote MGMT |