1
3 2
4
Water will pool to the center of the cross when the rain gauge is level.
If water remains on
If necessary, adjust the level using the screw.
NOTE For best results, ensure the base is horizontal to allow maximum drainage of any collected rain.
GETTING STARTED
SET UP BASE STATION
NOTE Install batteries matching the polarities (+ /
For continuous use, install the AC adapter. The batteries are for
NOTE The base station and adapter should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the base station and adapter.
INSERT BATTERIES
1.Remove the battery compartment.
2.Insert the batteries, matching the polarities (+ /
3.Press RESET after each battery change.
NOTE Do not use rechargeable batteries. It is recommended that you use alkaline batteries with this product for longer performance.
NOTE Batteries should not be exposed to excessive heat such as sunshine or fire.
LOCATION | MEANING | |
Weather forecast area | Base station batteries low | |
Rainfall / UV / Wind / Outdoor | Sensor batteries low | |
temperature / humidity area | ||
| ||
|
|
EN
SENSOR DATA TRANSMISSION
To search for a sensor:
1.Select desired area to activate.
2.Press and hold CH and MEM.
3. icons will flash for 5 minutes.
NOTE Unit will search only for already registered sensors or new sensors reset within last 30 minutes. To register a new sensor, reset sensor prior to search.
The sensor reception icon in the remote sensor area shows the status:
ICON | DESCRIPTION |
| Base station is searching for sensor(s) |
|
|
| A channel has been found |
|
|
| Sensor 1 data received |
The sensor cannot be found.
TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock automatically with a clock signal.
WMR200:
Slide switch to EU / UK to select the desired signal.
•EU:
•UK:
WMR200A:
indicates the status of the clock reception signal.
ICON | MEANING |
|
|
| Time is synchronized |
| Receiving signal is strong |
|
|
| Time is not synchronized |
| Receiving signal is weak |
|
|
NOTE Reception takes
To enable / disable signal reception:
Press and hold clock area to enable / disable signal reception. A beep will sound to confirm action.
NOTE For best reception, the base station should be placed on a flat,
MANUALLY SET CLOCK
1. Press clock area to activate.
2.Press SET to toggle between time zone offset, 12/24 hr format, hour, minute, year, day / month, month, day, time zone.
3.Once in desired setting, press UP or DWN to change the settings.
4.Press:
•SET to confirm and continue to next setting OR
•touch panel area (except tool bar) to confirm and exit.
WMR200: Time zone offset sets the clock +/- 23 hours from the received clock signal time.
WMR200A: Select the time zone: (PA) Pacific, (EA) Eastern, (CE) Central or (MO) Mountain.
NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S).
7