Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 owner manual Installation Diagram

Page 27

Section 7 - Installation Diagram

Centurion Liquid-cooled 15 kW and 25 kW Generators

Drawing No. 0E1533-A

Generac® Power Systems, Inc. 25

Image 27
Contents Centurion Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceInside Front Cover General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationGenerator Fuel System ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch Main Circuit BreakerLifting the Generator Unpacking‹ 1.10.1 Generator SpecificationsReconfiguring the Fuel System Fuel ConsumptionEngine OIL Recommendations Torque SpecificationsBefore Installation Generator Installation‹ 2.1.1 Nfpa Standards Generator LocationGenerator Mounting Support Basic Standby Electric SystemTotal Circuit Isolation Method Emergency Circuit Isolation MethodGrounding the Generator ‹ 2.10.1 Vented Batteries Transfer Switch Start Signal ConnectionsBattery Installation Generator AC Neutral ConnectionsPreparation Before START-UP Control Console Components Using a Standard GTS Transfer Switch‹ 3.2.2 AUTO/OFF/MANUAL Switch ‹ 3.2.3 Fault Indicator LampEngine Block Heater ‹ 3.2.6 SET Exercise Time SwitchManual Transfer START-UP Automatic Operation Weekly Exercise CycleCooling System Overload Protection for Engine DC Electrical SystemChecking Fluid Levels ‹ 4.5.5 Perform Visual Inspection ‹ 4.4.2 Battery Fluid‹ 4.5.2 Check Battery ‹ 4.5.4 Inspect Cooling System‹ 4.5.11 Spark Plugs Miscellaneous Maintenance‹ 4.5.10 Changing the Engine AIR Cleaner ‹ 4.6.1 Cleaning the Generator‹ 4.6.5 Rodent Protection ‹ 4.6.2 Battery‹ 4.6.3 Battery Maintenance ‹ 4.6.4 Battery ReplacementFuel Pipe Sizing OUT of Service Procedure‹ 4.7.1 Removal from Service ‹ 4.7.2 Return to ServiceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCenturion Liquid-cooled 15 kW and 25 kW Generators Installation Diagram Section DC-VR Customer Connection 120/240V 1-PHASE To Control Panel Terminal Strip ASM Motor Stepper Housing Governor ConnectorConnector Interface Assembly Cover Connector HousingWasher Flat 5/16 Zinc BASE,MOUNTING 1.5L STNRD&ACSTCWasher Shakeproof EXT 5/16 STL Dampener VibrationWeld Stud Under Roof Roof ACSTC&STND Cmprtmnt 1.5L Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Assembly Cover AccessPanel for Access Cover Cable Baffle Cntrl PNL 1.5L Acoustic Roof Acstc & Stnd Cmprtmnt 1.5LDoor Weldment 1.5 EPS Washer Self Locking DomeTo a Holder Fuse Wire AssemblySilksc HourmeterHardware ENGINE-1.5L Switch OIL PressureARM Adjust Alternator Ground Wire Starter16 7 Guard FAN 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Venturi 1.5L ModineVapor Flange Fuel Inlet Cover AIR CleanerGasket AIR Cleaner Adapter Weldment Mounting BaseTo Engine Crankshaft Assy Rotor 20KW Housing BlowerAssy Rotor 10KW Assy Rotor 15KWBattery Post Cover RED+ ASSY,WIRE#16 REDBOOT, Battery Cable BRACKET, Battery Hold DownPIPE,EXHAUST 1.5L STNDRD&ACSTC Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron Saddle 2 InchYour Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule