Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 Assy Rotor 10KW, Assy Rotor 15KW

Page 47

 

 

 

 

Section 9 - Exploded Views and Parts

 

 

 

 

 

 

 

 

 

 

 

 

Centurion Liquid-cooled 15 kW and 25 kW Generators

 

 

 

 

 

 

Alternator — Drawing No. 0A9348-F

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

1

098671

1

ASSY ROTOR 10KW

 

 

 

 

098681

1

ASSY ROTOR 15KW

 

 

 

 

098675

1

ASSY ROTOR 20KW

 

 

 

 

098936

1

ASSY ROTOR 25KW

 

 

2

0A5336A

1

HOUSING BLOWER

 

 

3

0A1659

1

SCREEN AIR OUTLET

 

 

4

071912

4

SCREW PPHM M5-0.8 X 8 SS

 

 

5

049226

4

WASHER LOCK M5

 

 

6

051713

4

WASHER FLAT M5

 

 

7

022129

4

WASHER LOCK M8-5/16

 

 

8

098672

1

ASSY STATOR 10KW A

 

 

 

 

098673

1

ASSY STATOR 10KW D

 

 

 

 

098674

1

ASSY STATOR 10KW GJK

 

 

 

 

098682

1

ASSY STATOR 15KW 1PH A

 

 

 

 

098683

1

ASSY STATOR 15KW 3PH D

 

 

 

 

098684

1

ASSY STATOR 15KW 1PH GJK

 

 

 

 

098676

1

ASSY STATOR 20KW 1PH A

 

 

 

 

098677

1

ASSY STATOR 20KW 1PH D

 

 

 

 

098678

1

ASSY STATOR 20KW 1PH GJK

 

 

 

 

097620

1

ASSY STATOR 25KW 1PH A

 

 

 

 

098937

1

ASSY STATOR 25KW 1PH D

 

 

 

 

097621

1

ASSY STATOR 25KW 3PH D

 

 

9

0A5382

1

BEARING CARRIER REAR

 

 

10

075591

1

ASSY HOLDER BRUSH

 

 

11

075476

4

SCREW PPHM M4-0.7 X 16

 

 

12

0A5601

1

COVER REAR BEARING CARRIER

 

 

13

075554B

4

BOLT STATOR X 16" LG

 

 

14

0A9375

4

SCREW RHM #10-24 X 2

 

 

15

022152

4

WASHER LOCK #10

 

 

16

097146

1

FAN & RING GEAR ASSEM.

 

 

17

042558

1

KEY SQ 3/8 X 1 STEEL

 

 

18

0A5061

1

SPACER-FLEX PLATE

 

 

19

0A4989

1

PLATE, FLEX

 

 

20

053557

1

SCREW HHC M12-1.75 X 40 G8.8

 

 

21

051769

6

WASHER LOCK M12

 

 

22

049541

4

SCREW HHC M10-1.5 X 35 G8.8

 

 

23

046526

4

WASHER LOCK M10

 

 

24

045772

4

NUT HEX M10-1.5 G8 YEL CHR

 

 

26 *

087599

1

PLUG PLASTIC 3/8 NPT

 

 

27

077043E

1

FLEX CONDUIT 1" BLACK (NOT SHOWN)

 

 

28

022131

4

WASHER FLAT 3/8-M10 ZINC

 

 

29

072578

1

SPACER ROTOR SHAFT

 

 

30

0A7043

5

SCREW HHC M12-1.25 X 25 G8.8

 

 

31

049808

5

WASHER FLAT M12

 

 

32

058589

1

DECAL WARN ENG START

 

 

33

023365

4

WASHER SHAKEPROOF INT #8

 

 

35

0A8830

4

WASHER FLAT .34 ID X .75 OD

 

 

36

072080

1

DECAL, DANGER STANBY UNITS

 

 

* USED ON PRE-PACKAGED UNITS ONLY

Generac® Power Systems, Inc. 45

Image 47
Contents Centurion Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceInside Front Cover General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationGenerator Fuel System ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch Main Circuit BreakerLifting the Generator Unpacking‹ 1.10.1 Generator SpecificationsReconfiguring the Fuel System Fuel ConsumptionEngine OIL Recommendations Torque SpecificationsBefore Installation Generator Installation‹ 2.1.1 Nfpa Standards Generator LocationGenerator Mounting Support Basic Standby Electric SystemGrounding the Generator Total Circuit Isolation MethodEmergency Circuit Isolation Method ‹ 2.10.1 Vented Batteries Transfer Switch Start Signal ConnectionsBattery Installation Generator AC Neutral ConnectionsPreparation Before START-UP Control Console Components Using a Standard GTS Transfer Switch‹ 3.2.2 AUTO/OFF/MANUAL Switch ‹ 3.2.3 Fault Indicator LampEngine Block Heater ‹ 3.2.6 SET Exercise Time SwitchManual Transfer START-UP Automatic Operation Weekly Exercise CycleChecking Fluid Levels Cooling SystemOverload Protection for Engine DC Electrical System ‹ 4.5.5 Perform Visual Inspection ‹ 4.4.2 Battery Fluid‹ 4.5.2 Check Battery ‹ 4.5.4 Inspect Cooling System‹ 4.5.11 Spark Plugs Miscellaneous Maintenance‹ 4.5.10 Changing the Engine AIR Cleaner ‹ 4.6.1 Cleaning the Generator‹ 4.6.5 Rodent Protection ‹ 4.6.2 Battery‹ 4.6.3 Battery Maintenance ‹ 4.6.4 Battery ReplacementFuel Pipe Sizing OUT of Service Procedure‹ 4.7.1 Removal from Service ‹ 4.7.2 Return to ServiceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCenturion Liquid-cooled 15 kW and 25 kW Generators Installation Diagram Section DC-VR Customer Connection 120/240V 1-PHASE To Control Panel Terminal Strip ASM Motor Stepper Housing Governor ConnectorConnector Interface Assembly Cover Connector HousingWasher Flat 5/16 Zinc BASE,MOUNTING 1.5L STNRD&ACSTCWasher Shakeproof EXT 5/16 STL Dampener VibrationWeld Stud Under Roof Roof ACSTC&STND Cmprtmnt 1.5L Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Assembly Cover AccessPanel for Access Cover Cable Baffle Cntrl PNL 1.5L Acoustic Roof Acstc & Stnd Cmprtmnt 1.5LDoor Weldment 1.5 EPS Washer Self Locking DomeTo a Holder Fuse Wire AssemblySilksc HourmeterHardware ENGINE-1.5L Switch OIL PressureARM Adjust Alternator Ground Wire Starter16 7 Guard FAN 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Venturi 1.5L ModineVapor Flange Fuel Inlet Cover AIR CleanerGasket AIR Cleaner Adapter Weldment Mounting BaseTo Engine Crankshaft Assy Rotor 20KW Housing BlowerAssy Rotor 10KW Assy Rotor 15KWBattery Post Cover RED+ ASSY,WIRE#16 REDBOOT, Battery Cable BRACKET, Battery Hold DownPIPE,EXHAUST 1.5L STNDRD&ACSTC Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron Saddle 2 InchPURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule