Generac 004912-0, 004912-1, 004913-0, 004913-1 owner manual Your Warranty Rights and Obligations

Page 50

Section 10 – Warranty

Centurion Liquid-cooled 15 kW and 25 kW Generators

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board (CARB) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System Warranty on your new engine.* In California, new utility, and lawn and garden equipment engines must be designed, built and equipped to meet the state’s stringent anti-smog standards. Generac will warrant the emission control system on your engine for the periods of time listed below provided there has been no abuse, neglect, unapproved modification or improper maintenance of your engine.

Your emission control system may include parts such as the carburetor, ignition system and exhaust system. Generac will repair your engine at no cost to you for diagnosis, replacement parts and labor, should a warrantable condition occur.

MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:

Emissions control systems on 1995 and later model year engines are warranted for two years as hereinafter noted. If, during such warranty period, any emission-related component or system on your engine is found to be defective in materials or workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service Facility.

PURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES:

As the engine purchaser/owner, you are responsible for the completion of all required maintenance as listed in your factory supplied Owner’s Manual. For warranty purposes, Generac recommends that you retain all receipts covering maintenance on your engine. However, Generac cannot deny warranty solely due to the lack of receipts or for your failure to ensure the completion of all scheduled maintenance.

As the engine purchaser/owner, you should, however, be aware that Generac may deny any and/or all warranty coverage or responsibility if your engine, or a part/component thereof, has failed due to abuse, neglect , improper maintenance or unapproved modifications, or the use of counterfeit and/or “grey market” parts not made, supplied or approved by Generac.

You are responsible for presenting your engine to a Generac Authorized Warranty Service Facility as soon as a problem occurs. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.

Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Facility. To locate the Generac Authorized Warranty Service Facility nearest you, call our toll-free number:

1-800-333-1322

IMPORTANT NOTE: This warranty statement explains your rights and obligations under the Emission Control System Warranty (ECS Warranty), which is provided to you by Generac pursuant to California law. See also the “Generac Limited Warranties for Generac Power Systems, Inc.,” which is enclosed herewith on a separate sheet, also provided to you by Generac. The ECS Warranty applies only to the emission control system of your new engine. If there is any conflict in terms between the ECS Warranty and the Generac Warranty, the ECS Warranty shall apply except in circumstances where the Generac Warranty may provide a longer warranty period. Both the ECS Warranty and the Generac Warranty describe important rights and obligations with respect to your new engine.

Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty service, evidence must be presented showing the date of the sale to the original purchaser/owner.

If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at the following address:

ATTENTION WARRANTY DEPARTMENT

GENERAC POWER SYSTEMS, INC.

P.O. BOX 297

WHITEWATER, WI 53190

Part 1

48 Generac® Power Systems, Inc.

Image 50
Contents Centurion ‹ HOW to Obtain Service Authorized Service Dealer Location‹ Operation and Maintenance IntroductionInside Front Cover General Hazards Electrical Hazards Automatic System Operation Transfer SwitchGenerator Generator AC Connection SystemsMain Circuit Breaker ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch Generator Fuel SystemUnpacking Lifting the GeneratorFuel Consumption SpecificationsReconfiguring the Fuel System ‹ 1.10.1 GeneratorGenerator Installation Torque SpecificationsBefore Installation Engine OIL RecommendationsBasic Standby Electric System Generator LocationGenerator Mounting Support ‹ 2.1.1 Nfpa StandardsGrounding the Generator Total Circuit Isolation MethodEmergency Circuit Isolation Method Generator AC Neutral Connections Transfer Switch Start Signal ConnectionsBattery Installation ‹ 2.10.1 Vented BatteriesPreparation Before START-UP ‹ 3.2.3 Fault Indicator Lamp Using a Standard GTS Transfer Switch‹ 3.2.2 AUTO/OFF/MANUAL Switch Control Console ComponentsWeekly Exercise Cycle ‹ 3.2.6 SET Exercise Time SwitchManual Transfer START-UP Automatic Operation Engine Block HeaterChecking Fluid Levels Cooling SystemOverload Protection for Engine DC Electrical System ‹ 4.5.4 Inspect Cooling System ‹ 4.4.2 Battery Fluid‹ 4.5.2 Check Battery ‹ 4.5.5 Perform Visual Inspection‹ 4.6.1 Cleaning the Generator Miscellaneous Maintenance‹ 4.5.10 Changing the Engine AIR Cleaner ‹ 4.5.11 Spark Plugs‹ 4.6.4 Battery Replacement ‹ 4.6.2 Battery‹ 4.6.3 Battery Maintenance ‹ 4.6.5 Rodent Protection‹ 4.7.2 Return to Service OUT of Service Procedure‹ 4.7.1 Removal from Service Fuel Pipe SizingScheduled Maintenance Service Maintenance Interval InformationLevel Maintenance Level Troubleshooting Points Problem Cause CorrectionCenturion Liquid-cooled 15 kW and 25 kW Generators Installation Diagram Section DC-VR Customer Connection 120/240V 1-PHASE To Control Panel Terminal Strip Cover Connector Housing Housing Governor ConnectorConnector Interface Assembly ASM Motor StepperDampener Vibration BASE,MOUNTING 1.5L STNRD&ACSTCWasher Shakeproof EXT 5/16 STL Washer Flat 5/16 ZincWeld Stud Under Roof Assembly Cover Access Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Roof ACSTC&STND Cmprtmnt 1.5LPanel for Access Cover Cable Washer Self Locking Dome Roof Acstc & Stnd Cmprtmnt 1.5LDoor Weldment 1.5 EPS Baffle Cntrl PNL 1.5L AcousticTo a Hourmeter Wire AssemblySilksc Holder FuseHardware Ground Wire Starter Switch OIL PressureARM Adjust Alternator ENGINE-1.5L16 7 Venturi 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Guard FAN 1.5L ModineVapor Weldment Mounting Base Cover AIR CleanerGasket AIR Cleaner Adapter Flange Fuel InletTo Engine Crankshaft Assy Rotor 15KW Housing BlowerAssy Rotor 10KW Assy Rotor 20KWBRACKET, Battery Hold Down ASSY,WIRE#16 REDBOOT, Battery Cable Battery Post Cover RED+Saddle 2 Inch Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron PIPE,EXHAUST 1.5L STNDRD&ACSTCPURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule