Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 Silksc, Hourmeter, Holder Fuse, Guardian

Page 39

Section 9 - Exploded Views and Parts

Centurion Liquid-cooled 15 kW and 25 kW Generators Control Panel — Drawing No. 0E0778-G

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D9322

1

PANEL BACK & BOTTOM GUARDIAN

2

0D9332

1

PANEL LH SIDE GUARDIAN & SPRN

3

0D9325A

1

PANEL FRONT CONTROL GUARDIAN

 

 

 

W/ SILKSC

4

0D9330

1

PANEL RH SIDE C-PANEL SML BRK

5

0C1457

1

HOURMETER

6

064009

1

LIGHT 12VDC .02A LED RED PILOT

7

032300

1

HOLDER FUSE

8

022676

1

FUSE 15A X AGC15

9

0E4494

1

SWITCH ROC DPDT ON-OFF-ON

10

082573

1

SWITCH ROCKER DPST 125V SPD

11

083048

1

ASSEMBLY REGULATOR POTTED

12

083264

1

TFMR ASM CMA 240/12V

13

076009A

1

PP LOGIC ASM 50/60HZ

14 *

0E0331

1

HARNESS CONTROL PANEL PP

 

 

 

GUARDIAN

15

056739

1

RELAY SOLENOID 12VDC PNL MNT

16

049350

1

CIRCT BRK 4 X 1 ETA 46-500-P

17

047822

1

BLOCK TERM 20A 7 X 6 X 1100V

18

048766

1

BLOCK TERM 20A 2 X 6 X 1100V

19

057335

1

BLOCK TERM 20A 20 X 6 X 1100V

20

098647

1

ASSY L.C. ELECT GOV

21

0E1454

1

DECAL CUST. CONNT. PRE-PACK1.5L

22

0E1459

1

DECAL TERMINAL STRIP PRE-PACK

23

072566

4

NUT SPACER.250 PCB

24

080882

4

SCREW PPH TAPPING #6 X 5/8 SS

25

0A8955

2

SCREW PHM M6-1.0 X 20MM

26

022097

3

WASHER LOCK M6-1/4

27

022473

2

WASHER FLAT 1/4-M6 ZINC

28

0C2212

10

SCREW PHTT M4-0.7 X 16 ZYC

29

023762

2

WASHER SHAKEPROOF EXT #10

 

 

 

STL

ITEM

PART NO.

QTY.

DESCRIPTION

30

0C2267

14

SCREW HHTT M5-0.8 X 12 BP

31

023897

15

WASHER FLAT #10 ZINC

32

0C2454

4

SCREW TH-FRM M6-1X16 N WA Z/JS

33

054199

1

DECAL HIGH VOLTAGE

34

081988

1

DECAL EXERCISE INFO

35

0E2514

1

STRAIGHT WIRE CONNECTOR 1 1/2"

36

0A1354A

1

REGULATOR - DC ALT

37

074908

4

SCREW HHTT M5-0.8 X 10 BP

38

020911

4

SCREW PPHM M5-0.8 X 30 ZINC

39

051713

5

WASHER FLAT M5

40

049226

5

WASHER LOCK M5

41

051716

5

NUT HEX M5-0.8 G8 YEL CHR

42

036261

4

RIVET POP .125 X .129-.133/#30

43

0D9334

1

PANEL, TOP

44

061979

1

BUS BAR

45

022237

1

WASHER LOCK 3/8

46

022241

1

NUT HEX 3/8-16 STEEL

47

057073

1

JUNCTION BLOCK 3/8-16

48

055440

1

SCREW HHC M5-0.8 X 25 G8.8

49

0D8671

1

HINGE CONTINUOUS 1.5L CNTL PNL

50

0912970080

1

WIRE ASSEMBLY

51

049813

1

NUT HEX M6 X 1.0 G8 YEL CHR

52

033121

1

SCREW HHC #10-32 X 1/2

53

026850

1

WASHER SHAKEPROOF EXT 1/4

 

 

 

STL

54

022158

1

NUT HEX #10-32 STEEL

55

022152

1

WASHER LOCK #10

56

0A3968

1

CAPACITOR FILTER ASY

57

0C2323

2

SCREW PHTT #6-32 X 5/8 ZYC

58

0E3783

1

DECAL WARNING REMOVE FUSE

* NOT SHOWN

Generac® Power Systems, Inc. 37

Image 39
Contents Centurion Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceInside Front Cover General Hazards Electrical Hazards Generator AC Connection Systems Transfer SwitchGenerator Automatic System OperationGenerator Fuel System ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch Main Circuit BreakerLifting the Generator Unpacking‹ 1.10.1 Generator SpecificationsReconfiguring the Fuel System Fuel ConsumptionEngine OIL Recommendations Torque SpecificationsBefore Installation Generator Installation‹ 2.1.1 Nfpa Standards Generator LocationGenerator Mounting Support Basic Standby Electric SystemTotal Circuit Isolation Method Emergency Circuit Isolation MethodGrounding the Generator ‹ 2.10.1 Vented Batteries Transfer Switch Start Signal ConnectionsBattery Installation Generator AC Neutral ConnectionsPreparation Before START-UP Control Console Components Using a Standard GTS Transfer Switch‹ 3.2.2 AUTO/OFF/MANUAL Switch ‹ 3.2.3 Fault Indicator LampEngine Block Heater ‹ 3.2.6 SET Exercise Time SwitchManual Transfer START-UP Automatic Operation Weekly Exercise CycleCooling System Overload Protection for Engine DC Electrical SystemChecking Fluid Levels ‹ 4.5.5 Perform Visual Inspection ‹ 4.4.2 Battery Fluid‹ 4.5.2 Check Battery ‹ 4.5.4 Inspect Cooling System‹ 4.5.11 Spark Plugs Miscellaneous Maintenance‹ 4.5.10 Changing the Engine AIR Cleaner ‹ 4.6.1 Cleaning the Generator‹ 4.6.5 Rodent Protection ‹ 4.6.2 Battery‹ 4.6.3 Battery Maintenance ‹ 4.6.4 Battery ReplacementFuel Pipe Sizing OUT of Service Procedure‹ 4.7.1 Removal from Service ‹ 4.7.2 Return to ServiceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCenturion Liquid-cooled 15 kW and 25 kW Generators Installation Diagram Section DC-VR Customer Connection 120/240V 1-PHASE To Control Panel Terminal Strip ASM Motor Stepper Housing Governor ConnectorConnector Interface Assembly Cover Connector HousingWasher Flat 5/16 Zinc BASE,MOUNTING 1.5L STNRD&ACSTCWasher Shakeproof EXT 5/16 STL Dampener VibrationWeld Stud Under Roof Roof ACSTC&STND Cmprtmnt 1.5L Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Assembly Cover AccessPanel for Access Cover Cable Baffle Cntrl PNL 1.5L Acoustic Roof Acstc & Stnd Cmprtmnt 1.5LDoor Weldment 1.5 EPS Washer Self Locking DomeTo a Holder Fuse Wire AssemblySilksc HourmeterHardware ENGINE-1.5L Switch OIL PressureARM Adjust Alternator Ground Wire Starter16 7 Guard FAN 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Venturi 1.5L ModineVapor Flange Fuel Inlet Cover AIR CleanerGasket AIR Cleaner Adapter Weldment Mounting BaseTo Engine Crankshaft Assy Rotor 20KW Housing BlowerAssy Rotor 10KW Assy Rotor 15KWBattery Post Cover RED+ ASSY,WIRE#16 REDBOOT, Battery Cable BRACKET, Battery Hold DownPIPE,EXHAUST 1.5L STNDRD&ACSTC Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron Saddle 2 InchYour Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule