The safety alert symbol () is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard.The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others.You must also make sure that the procedure, work method or operating technique that you choose does not render the generator unsafe.

NOTE: Your generator is equipped with a spark arrester muffler.The spark arrester must be maintained in effective working order by the owner/operator. In the State of California, a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands.

Hazard Symbols and Meanings

Toxic Fumes

Rotating Parts

Electrical Shock

Hot Surface

Explosion

Fire

Explosive Pressure

Chemical Burn

DANGER

Storage batteries give off explosive hydrogen gas during recharging.

Slightest spark will ignite hydrogen and cause explosion.

Battery electrolyte fluid contains acid and is extremely caustic.

Contact with battery contents will cause severe chemical burns.

A battery presents a risk of electrical shock and high short circuit current.

DO NOT dispose of battery in a fire.

DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.

DO NOT open or mutilate the battery.

Wear protective goggles, rubber apron, and rubber gloves.

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles or structures causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

3

Image 3
Contents 12000 Table of Contents Hazard Symbols and Meanings Important Safety RulesSafety Rules For the Home Owner Installation AssistanceIntroduction Owner OrientationFuel Factors Generator LocationHome Generator System Location Device Running Watts Essential CircuitsShipment Contents UnpackingDelivery Inspection Unit Data Decal located on base Identifies unit by Know Your Home Generator SystemKnow Your System Control Panel Manual Over-Ride Switch With system switchAccess Doors To Open an Access DoorTo Close an Access Door Gaseous Fuel System Battery ConnectionBefore Initial START-UP Engine OilServicing the System Setting Exercise TimerTo perform the Set Exercise procedure Automatic OperationFault Detection System Engine Fail To Start Oil Temperature HighTransfer Switch Fault Low Voltage GeneratorStorage Generator MaintenanceTo Clean the Generator When Calling the FactoryProblem Cause Correction TroubleshootingPage Limited Warranty Tabla DE Contenido Símbolos de Peligro y Significados Instrucciones Importantes DE SeguridadPeligro AdvertenciaLos generadores producen un voltaje muy poderoso PrecauciónAsistencia para la instalación Conserve Estas InstruccionesIntroducción Orientación Para EL PropietarioDistancias Desde el Generador Factores Relacionados con el CombustibleUbicación del Generador de Reserva Ubicación del GeneradorCircuitos Fundamentales Pautas Generales para la Ubicación del GeneradorDispositivo Vatiaje de Selección de los Circuitos Fundamentales DesempaqueInspección al Momento de la Entrega Contenido de la CajaConozca SU Generador Doméstico DE Reserva Fusible de 15 Amperios Protege los circuitos de control de Conozca EL Panel DE Control DEL SistemaPuertas de Acceso Para abrir una puerta de accesoPara cerrar una puerta de acceso Sistema de Combustible Gaseoso Antes DEL Arranque InicialAceite de Motor Conexión de la BateríaParo del Sistema Configuración del Temporizador de PrácticaOperación Automática Verificación de la Operación AutomáticaSistema DE Detección DE Fallas Sobrevelocidad del Motor Baja TensiónEl Motor no Arranca Baja FrecuenciaPara Limpiar el Generador Mantenimiento DEL GeneradorAlmacenamiento Cambio del Aceite del MotorReparacion DE Averias Notas Garantía Limitada Table DES Matières Avertissement Symboles de Danger et MoyensNE touchez PAS les fils dénudés ou les boîtiers Conseils AU Propriétaire Aide à lInstallationConservez CES Instructions IntroductionDégagement Autour de la Génératrice Emplacement du Génératrice d’état d’AttenteEmplacement de la Génératrice Facteurs Relatifs au CombustibleDirectives Générales Concernant lEmplacement Circuits EssentielsAppareil Watts Sélection des Circuits Essentiels DéballageVérification de la Livraison Contenu de la BoîteFAMILIARISEZ-VOUS Avec Votre Groupe Électrogène Bouchon de Remplissage dHuile Enlevez-le pour effectuerDécalque Apposé sur lUnité situé sur la base Identifie La position normale de fonctionnement est la position Portes dAccès Pour ouvrir une porte d’accèsPour fermer une porte d’accès Système de Combustible Gazeux Avant LE Démarrage InitialHuile à Moteur Branchement de la BatterieRéglage de la Minuterie du Cycle dExercice Fonctionnement AutomatiqueArrêt du Système Vérification du Fonctionnement AutomatiqueFaible Tension de la Batterie Système DE Détection DES PannesRéarmement du Système de Détection des Pannes Aucun DEL Batterie déchargéeEmballement du Moteur Basse TensionLe Moteur Ne Démarre Pas Basse FréquencePour Nettoyer le Générateur Entretien DU GénérateurRemisage Vidange de lHuile MoteurDépannage Remarques Remarques Garantie Limitée