Briggs & Stratton 030333-0 manual Maintenance Schedule, Generator Maintenance

Page 15

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

Maintenance Schedule - Fill in Dates as You Complete Regular Service

Maintenance Task

 

 

 

 

Service Intervals

 

 

Service Dates

 

Before

 

Every 25 Hours

 

Every 50 Hours

 

Every 100

 

Every 250

 

 

 

 

 

 

 

 

 

 

 

 

Each Use

 

or Yearly

 

or Yearly

 

Hours or Yearly

 

Hours or Yearly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean debris

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check oil level

X

 

 

 

 

 

 

 

 

 

 

 

Change engine oil

 

 

 

 

X1

 

 

 

 

 

 

 

Service air cleaner

 

 

X2

 

 

 

 

 

 

 

 

 

Service fuel valve

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service spark plug

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service spark arrester

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean cooling system

 

 

 

 

 

 

X2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check valve clearance

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prepare for storage

 

 

If unit is to remain idle for longer than 30 days.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter. Change oil sooner when operating under dirty or dusty conditions.

2Replace more often under dirty or dusty conditions.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See an authorized Briggs & Stratton dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

15

Image 15
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Equipment Description Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsWhen Testing for Engine Spark Contact with muffler area can result in serious burnsUnintentional sparking can result in fire or electric shock Unpack Generator AssemblyInstall Wheel Kit Install the wheel kit as followsHigh Altitude Add Engine OilAdd Fuel Fuel must meet these requirementsSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationFuel Valve Used to turn fuel supply on and off to engine Features and ControlsUsed to supply electrical power for the operation Volt AC, 20 Amp, Duplex Receptacles May beVolt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationConnecting Electrical Loads Stopping the EngineMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Maintenance ScheduleGenerator Maintenance Fuel Valve Maintenance Engine MaintenanceOil Service Spark Arrester Service Air CleanerService Spark Plug Install spark plug and tighten firmlyCarburetor Adjustment Air Cooling SystemCheck Valve Clearance Storage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty 800 Product SpecificationsCommon Service Parts AC Load CurrentManual del operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadCuando Transporte O Repare EL Equipo Cuando Anada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor Cuando Ajuste O Haga Reparaciones a SU Máquina GeneradorMontaje Desembalaje del generadorInstale el juego de ruedas Gran altitud Agregar aceite al motorVuelva a colocar el tapón y apriételo firmemente Evite el daño del generadorRequisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorAmperios, monofásica de 60 Hz Controles y característicasAmps o mayores Juegos de cordones y enchufes conectoresTomas eléctricas dobles de 120 V CA y 20 a Cada receptáculo está protegido por un disyuntor basculanteEncienda el motor OperandoGire la válvula de combustible hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploMantenimiento Plan de mantenimientoMantenimiento del generador Mantenimiento de la válvula de combustible Mantenimiento del motorAceite Recomendaciones sobre el aceite Cambio de aceite del motor Comprobación del nivel de aceiteInstale el tapón de llenado de aceite, apriete firmemente Adición de aceite del motorServicio del depurador de aire Servicio del bujíaLimpie la pantalla apagachispas Ajuste del carburador Limpie e inspeccione el apagachispas de la siguiente maneraSistema de refrigeración de aire Revisión de la holgura de las válvulasAlmacenamiento Problemo Causa Accion Resolución de problemasOperaciones de mantenimiento que se enumeran en las GarantíasGarantía del sistema de control de emisiones Responsabilidades de la garantía del propietarioInformación sobre emisiones Garantía Limitada Page Especificaciones del producto Servicio común despideCorriente Carga de C.A Manuel d’utilisation Date d’achat Où nous trouverGénératrice MoteurOpération Fonctions et commandesSécurité de l’opérateur AssemblageRègles de sécurité Symboles de danger et moyensSécurité de l’opérateur Description de l équipementLorsque Vous Transportez OU Réparez Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLorsque Vous Réglez OU Réparez Votre Génératrice Le génératrice produit une tension élevéeUn backfeed dénergie électrique Unintentional peut résulter dans feu ou électriqueInstallation de l’ensemble de roues AssemblageDéballez la génératrice Évitez d’endommager le génératrice Ajoutez de lhuile à moteurAjoutez de lessence ’essence satisfait les exigences suivantesDégagements et mouvement de l’air Emplacement de la génératriceMise à la terre du système Exigences spécialesFonctions et commandes Prises doubles de 120 volts C.A., 20 a Cordons et prisesPrise verrouillable de 120/240 volts C.A., 30 a Cette prise alimente des charges monophasées deDémarrage du moteur OpérationRéglez la vanne de combustible à la position « Off » Raccordement de charges électriquesArrêt du moteur Poussez l’interrupteur à bascule à la position « Off »= 4,875 Ne pas surchargez générateurCapacité ExempleEntretien Calendrier d’entretienEntretien de la génératrice Nettoyage Huile Recommandations relatives à l’huileEntretien de la vanne de combustible Entretien du moteurEssuyez tout déversement d’huile Vérification du niveau d’huileAjout d’huile à moteur Vidange de l’huile moteurEntretien de la bougie dallumage Entretien du filtre à airVérification du jeu des soupapes Entretien du pare-étincellesNettoyez et inspectez le pare-étincelles comme suit Nettoyer le système de refroidissementEntreposage Dépannage Problème Cause SolutionPièces garanties GarantiesGarantie du dispositif antipollution Responsabilités de la garantie du propriétaireRéclamations et exclusions de couverture Renseignements sur les émissionsConnecteurs et dispositifs Durée de la couverture Aucun fraisGarantie Limitée Page Pièces d’entretien courant Caractéristiques du produit