Cleaning frequency chart

Cleaning tools and materials

A recommended cleaning sequence includes vacuuming the scanner transport, cleaning the residue from the feed module, separation roller or drive rollers and cleaning the imaging guides.

Use the chart below as a guide to how frequently you should clean your scanner.

Procedure

Start of

Middle of

Start of new

 

day

shift

shift

Vacuum output tray and input

x

 

 

areas (elevator and transport)

 

 

 

Clean all rollers

x

 

x

 

 

 

 

Vacuum transport area

x

x

x

 

 

 

 

Remove and vacuum under

x

 

 

background strips

 

 

 

Remove and clean imaging

x

 

x

guides

 

 

 

Vacuum under imaging guides

x

 

x

 

 

 

 

Run transport cleaning sheet

x

 

x

 

 

 

 

Wipe imaging guides with cloth

x

x

x

 

 

 

 

Use only these cleaning tools and materials when performing routine maintenance on your scanner. Use of any other cleaning materials could damage your scanner.

Kodak Digital Science Transport Cleaning Sheets

Kodak Digital Science Roller Cleaning Pads

Staticide Wipes for Kodak Scanners

A vacuum cleaner and tools

5-2

A-61500 May 2010

Image 41
Contents I600/i700 Series Scanners Contents Appendix a Introduction Scanner models New features Scanner features Speed/capacity Throughput Msds Safety informationEMC statements User precautionsGas springs warning United StatesConnection Power systemAcoustic emission For i700 Series Scanners only Microsoft Windows 7 64-bit Getting StartedMaking connections Scanner components Front view Stop/Pause and Start/Resume buttons Internal components Rear view Starting and stopping scanning Using the ScannerTurning the scanner on and off Manually ending scanning Automatically pausing and resuming the scannerMaterials Document preparationAdjusting the side guides and end stop Page Forward detent positions Exit deflector Adjusting the optional short document tray Automatic feeding Press Start/Resume Continuous feeding Manual feedingCalibrating the scanner Image calibration Page Click Calibrate Page Overview Enhanced PrinterFont size Printer specificationsAccessing the Enhanced Printer Changing the printer position Replacing the ink cartridge Page Replacing the blotter strips Replacing the ink cartridge carrier Page Maintenance Cleaning frequency chart Cleaning tools and materials Ordering parts Supplies and accessoriesOpening the pod Cleaning the output tray and elevator areaCleaning the separation roller tires Cleaning the drive rollersCleaning the feed module tires Close the printer access cover 61500 May Cleaning the scanner transport area Cleaning the imaging guides Cleaning the background stripsPage Running a transport cleaning sheet Replacing the feed module or feed module tires Replacement proceduresPage Locking tab Locking tab Slot Replacing the separation roller or separation roller tires Separation pad Replacing the preReplacing the imaging GuidesIndicator lights TroubleshootingLed display Description Accessing the Operator Log Page Page I600 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May Listing I600 Series ScannersNumerical Message 61500 May I700 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May I700 Series Scanners 61500 May Problem Possible Solution Problem solvingMaintenance Appendix a Accessories Scanner Type/Speed Appendix B SpecificationsKodak, 2010. All rights reserved. TM Kodak