Kodak 6J7611A manual Enhanced Printer and Patch Readers for more

Page 63

Messages

ID#

Operator Message

Clean upper imaging guide

293, 304

The upper imaging guide is dirty or there may be a small piece of

 

 

paper in the imaging guide area.

 

 

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

Document count exceeded

124

The document counter is larger than the maximum configured

maximum value

 

value.

 

 

• Reconfigure the scanner to allow a larger value for the

 

 

document counter. Refeed the document set.

Document too dark to deskew

143

Informational message. The scanner was unable to find the

 

 

document edges to determine the skew angle. A full-width, non-

 

 

deskewed image has been created.

 

 

• The document is too dark.

 

 

• The image is too large.

 

 

• Rescan using a fixed-sized cropping window.

Document too long

35, 36, 183

A document was measured which exceeded the configured

 

 

maximum allowable length. This may be due to a document

 

 

overlap.

 

 

• Check the host monitor to see if there are any overlapped

 

 

documents that may need to be rescanned.

 

 

This condition may also be caused by poor document

 

 

separation.

 

 

• Replace the separation roller tires and pre-separation pad.

 

 

See Chapter 5, Maintenance for procedures.

Front calibration failed

110

The front imaging path calibration failed.

 

 

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

 

 

• Try to calibrate the scanner again. Be sure you are using the

 

 

correct calibration target. See Chapter 3, “Calibrating the

 

 

Scanner”.

 

 

• If the problem persists, call Service.

Front calibration succeeded

111

Informational message. The front image path has been

 

 

successfully calibrated.

 

 

 

Image calibration is suggested

109

• Calibrate the scanner when the current batch of documents

 

 

has completed.

 

 

 

Image outside document area

177

Based on relative cropping parameters, the image to be

 

 

generated from this document would be outside the document

 

 

area.

 

 

• Make sure the relative cropping offset, width and length are

 

 

correct and that the correct document is being scanned.

 

 

 

Ink cartridge not installed

282

An attempt was made to use the Enhanced Printer without a ink

 

 

cartridge installed.

 

 

• Be sure the cable is properly connected to the printer carrier

 

 

and the ink cartridge is installed in the printer carrier. See

 

 

Chapter 4, The Enhanced Printer and Patch Readers for more

 

 

information.

 

 

NOTE:The ink cartridge must be installed before turning on the

 

 

scanner.

 

 

 

A-61500 May 2010

6-7

Image 63
Contents I600/i700 Series Scanners Contents Appendix a Introduction Scanner models New features Scanner features Speed/capacity Throughput Msds Safety informationUnited States User precautionsEMC statements Gas springs warningPower system Acoustic emissionConnection For i700 Series Scanners only Microsoft Windows 7 64-bit Getting StartedMaking connections Scanner components Front view Stop/Pause and Start/Resume buttons Internal components Rear view Using the Scanner Turning the scanner on and offStarting and stopping scanning Manually ending scanning Automatically pausing and resuming the scannerMaterials Document preparationAdjusting the side guides and end stop Page Forward detent positions Exit deflector Adjusting the optional short document tray Automatic feeding Press Start/Resume Continuous feeding Manual feedingCalibrating the scanner Image calibration Page Click Calibrate Page Overview Enhanced PrinterFont size Printer specificationsAccessing the Enhanced Printer Changing the printer position Replacing the ink cartridge Page Replacing the blotter strips Replacing the ink cartridge carrier Page Maintenance Cleaning frequency chart Cleaning tools and materials Ordering parts Supplies and accessoriesOpening the pod Cleaning the output tray and elevator areaCleaning the separation roller tires Cleaning the drive rollersCleaning the feed module tires Close the printer access cover 61500 May Cleaning the scanner transport area Cleaning the imaging guides Cleaning the background stripsPage Running a transport cleaning sheet Replacing the feed module or feed module tires Replacement proceduresPage Locking tab Locking tab Slot Replacing the separation roller or separation roller tires Guides Replacing the preSeparation pad Replacing the imagingIndicator lights TroubleshootingLed display Description Accessing the Operator Log Page Page I600 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May I600 Series Scanners Numerical MessageListing 61500 May I700 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May I700 Series Scanners 61500 May Problem Possible Solution Problem solvingMaintenance Appendix a Accessories Scanner Type/Speed Appendix B SpecificationsKodak, 2010. All rights reserved. TM Kodak