Kodak 6J7611A manual I600 Series Scanners Message listing

Page 62

i600 Series Scanners Message listing

Following is an alphabetic list of messages and corrective actions you can take if one of the following messages is encountered.

Messages

ID#

Operator Message

Background accessory changed

381

The Background Accessory was changed while the scanner was

while powered up

 

powered on.

 

 

• Turn the power off to the scanner, wait a few seconds and

 

 

power the scanner back on.

 

 

• If you get this message and you did not change the

 

 

Background Accessory, clean the scanner.

Cable unplugged

319

Some device on the FireWire bus was unplugged/plugged in.

 

 

• Check that all FireWire connectors are securely fastened.

 

 

 

Calibration failed

106, 331

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

 

 

• Try to calibrate the scanner again. Be sure you are using the

 

 

correct calibration target. See Chapter 3, “Calibrating the

 

 

scanner”.

 

 

• The calibration target is too small. A 12- x 12-inch calibration

 

 

target is required for image calibration.

 

 

• Calibration target is too narrow.

 

 

• If the problem persists, call Service.

 

 

 

Calibration succeeded

105, 342

Informational message. The scanner has been successfully

 

 

calibrated.

 

 

 

Call Service

Many ID

A condition was detected that may require repair.

 

numbers

• Turn the power off to the scanner, wait a few seconds and

 

 

power the scanner back on.

 

 

• If the problem persists, call Service and provide the ID number

 

 

of the error.

 

 

 

Cannot calibrate with white

184

Both a front and rear print head is installed in the scanner. Only

background

 

one print head can be installed at one time.

 

 

• Remove one of the print heads.

 

 

 

Cannot run with both printers

90

The White Background Accessory is installed in the scanner

installed

 

while the scanner is trying the calibrate.

 

 

• Remove the White Background Accessory before calibrating

 

 

the scanner.

 

 

 

Check document preparation

123, 135,

• The gap between your documents is too small.

 

81

• Make sure the leading edges of the documents are aligned.

 

 

See Chapter 3, “Document preparation” for more information.

 

 

• Check the condition of your feed module and separation roller

 

 

tires and your pre-separation pad. Clean and replace if

 

 

necessary.

Check imaging guides and lamps

149, 178,

• Verify that the imaging guides are installed correctly. See

 

139

Chapter 5, Maintenance.

 

 

• Clean both sides of the imaging guides and lower glass plate

 

 

between the lamps.

 

 

• Check that the white patch on the imaging guides is clean and

 

 

in good condition.

 

 

• If the problem persists, call Service.

 

 

 

Clean lower imaging guide

294

The lower imaging guide is dirty or there may be a small piece of

 

 

paper in the imaging guide area.

 

 

• Clean the imaging guides. See Chapter 5, Maintenance for

 

 

procedures.

 

 

 

6-6

A-61500 May 2010

Image 62
Contents I600/i700 Series Scanners Contents Appendix a Introduction Scanner models New features Scanner features Speed/capacity Throughput Safety information MsdsGas springs warning User precautionsEMC statements United StatesConnection Power systemAcoustic emission Getting Started For i700 Series Scanners only Microsoft Windows 7 64-bitMaking connections Scanner components Front view Stop/Pause and Start/Resume buttons Internal components Rear view Starting and stopping scanning Using the ScannerTurning the scanner on and off Automatically pausing and resuming the scanner Manually ending scanningDocument preparation MaterialsAdjusting the side guides and end stop Page Forward detent positions Exit deflector Adjusting the optional short document tray Automatic feeding Continuous feeding Manual feeding Press Start/ResumeCalibrating the scanner Image calibration Page Click Calibrate Page Enhanced Printer OverviewPrinter specifications Font sizeAccessing the Enhanced Printer Changing the printer position Replacing the ink cartridge Page Replacing the blotter strips Replacing the ink cartridge carrier Page Maintenance Cleaning frequency chart Cleaning tools and materials Supplies and accessories Ordering partsCleaning the output tray and elevator area Opening the podCleaning the drive rollers Cleaning the separation roller tiresCleaning the feed module tires Close the printer access cover 61500 May Cleaning the scanner transport area Cleaning the background strips Cleaning the imaging guidesPage Running a transport cleaning sheet Replacement procedures Replacing the feed module or feed module tiresPage Locking tab Locking tab Slot Replacing the separation roller or separation roller tires Replacing the imaging Replacing the preSeparation pad GuidesTroubleshooting Indicator lightsLed display Description Accessing the Operator Log Page Page I600 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May Listing I600 Series ScannersNumerical Message 61500 May I700 Series Scanners Message listing Enhanced Printer and Patch Readers for more Scanning Setup Guide for valid values Informational message. The pod was closed 61500 May I700 Series Scanners 61500 May Problem solving Problem Possible SolutionMaintenance Appendix a Accessories Appendix B Specifications Scanner Type/SpeedKodak, 2010. All rights reserved. TM Kodak