Emerson FPC user manual Figures

Page 4

FIGURES

Figure 1 Typical cabinet and floor planning dimension data, 23" (584mm) cabinet, 15-125 kVA . . . . . . . . 3 Figure 2 Typical cabinet and floor planning dimension data, 47" (1194mm) cabinet 50-300kVA . . . . . . . . 4 Figure 3 Recommended minimum service and ventilation clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 4 Floor pedestal details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 5 Electrical connection location for 23" (584mm) cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 6 Electrical connection location for 47" (1194mm) cabinet—Front view . . . . . . . . . . . . . . . . . . . . . 10 Figure 7 Electrical connection location for 47" (1194mm) cabinet—Rear view . . . . . . . . . . . . . . . . . . . . . . 10 Figure 8 Electrical connection location for 47" cabinet with SqD I-Linepanelboard—Front view. . . . . . . 11 Figure 9 Electrical connection location for 47" cabinet with SqD I-Linepanelboard—Rear view . . . . . . . 11 Figure 10 Low voltage control junction box connections, typical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 11 Main input junction box connections, typical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 12 Typical grounding arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 13 Typical Liebert FPC equipment arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 14 Simplified shutdown circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 15 Typical control wiring for units without monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Figure 16 Typical control wiring for units with monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 17 Basic monitoring panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 18 Power monitor panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

TABLES

Table 1 23-inch cabinet weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Table 2 47-inch cabinet weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3 Liebert FPC heat output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Table 4 Suggested minimum input wire size data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 5 Main input circuit breaker interrupting rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 6 Main input junction box electrical connections (4 wire) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 7 Main input junction box without transformer electrical connections (5 wire) . . . . . . . . . . . . . . . 14 Table 8 Low-voltage (control) junction box dimensions, typical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 9 Main input (power) junction box dimensions, typical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 10 Minimum grounding electrode conductor size (AWG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 11 Panelboard main circuit breaker torque specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 12 Branch circuit breaker torque specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 13 Terminal block compression lug torque specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 14 Torque specifications, general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 15 ASCII interface default parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 16 RS-232 ASCII port customer commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 17 Monitored parameters data definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

ii

Image 4
Contents Liebert FPC Page Table of Contents Figures Important Safety Instructions Unpacking and Preliminary Inspection Unpacking and InstallationHandling Considerations Inch cabinet weight Footprint and Floor cable access Cutout Dimensions cooling airflowFront FrontUnit Preparation Location ConsiderationsLiebert FPC heat output See Notes 2 Front and rear access is required. See Notes 1Full Load Heat Output Unit kVA BTU/Hr kW Floor Pedestal Installation Floor pedestal detailsAdditional Distribution Mounting & Wiring Power and Control WiringInput Power Connections Liebert FDC Distribution MountingElectrical connection location for 23 584mm cabinet FPC15000 Rev FPC15002 Rev Suggested minimum input wire size data Main input circuit breaker interrupting rating Junction Box Installation Main input junction box electrical connections 4 wireLow-voltage control junction box dimensions, typical Main input power junction box dimensions, typicalSystem Grounding Equipment GroundingSignal Reference Grid Grounding Electrode Conductor for FPCs With TransformerMinimum grounding electrode conductor size AWG Output VoltageTypical Liebert FPC With transformer grounding arrangement SystemTypical Liebert FPC without transformer groundingOutput Power Connections Liebert FPC Liebert FPC +24VDCUnit EPO MainLow Voltage Terminal Strip WiringFactory Typical control wiring for units with monitoring Optional Customer Alarm Inputs SummaryChecklists WarrantyInternal Inspection StartupTorque specifications, general Panelboard main circuit breaker torque specificationsBranch circuit breaker torque specifications Terminal block compression lug torque specificationsInspection Unit Serial Number Unit Model Number DateStartup Monitoring System Check-Out Customer Alarms Startup Procedures Normal System ShutdownNormal System Turn on Manual RestartPower Monitor Panel Alarm Present/SilenceBasic Monitor Panel Units Without Monitoring FPC16000Operating Instructions RS-232 Ascii port customer commands Ascii interface default parametersParameter Default Monitored parameters data definitions Field # Data item UnitsRepair Inspection and CleaningInspection Schedule Page Ne t ItiTi n That