Polycom 1725-36028-001 manual Trademark Information, Patent Information, Copyright Notice

Page 2
Trademark Information

SpectraLink 8000 Telephony Gateway Administration Guide

Trademark Information

Polycom® and the logo designs SpectraLink®

LinkPlus Link NetLink

SVP

Are trademarks and registered trademarks of Polycom, Inc. in the United States of America and various countries. All other trademarks used herein are the property of their respective owners.

Patent Information

The accompanying product is protected by one or more US and foreign patents and/or pending patent applications held by Polycom, Inc.

Copyright Notice

Copyright © 2000 to 2008 Polycom, Inc.

All rights reserved under the International and pan-American copyright Conventions.

No part of this manual, or the software described herein, may be reproduced or transmitted in any form or by any means, or translated into another language or format, in whole or in part, without the express written permission of Polycom, Inc.

Do not remove (or allow any third party to remove) any product identification, copyright or other notices.

Every effort has been made to ensure that the information in this document is accurate. Polycom, Inc. is not responsible for printing or clerical errors. Information in this document is subject to change without notice and does not represent a commitment on the part of Polycom, Inc.

Notice

Polycom, Inc. has prepared this document for use by Polycom personnel and customers. The drawings and specifications contained herein are the property of Polycom and shall be neither reproduced in whole or in part without the prior written approval of Polycom, nor be implied to grant any license to make, use, or sell equipment manufactured in accordance herewith.

Polycom reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Polycom to determine whether any such changes have been made.

No representation or other affirmation of fact contained in this document including but not limited to statements regarding capacity, response-time performance, suitability for use, or performance of products described herein shall be deemed to be a warranty by Polycom for any purpose, or give rise to any liability of Polycom whatsoever.

Contact Information

Please contact your Polycom Authorized Reseller for assistance.

Polycom, Inc.

4750 Willow Road, Pleasanton, CA 94588 http://www.polycom.com

2

PN: 1725-36028-001_T.doc

Image 2
Contents Utilizing SpectraLink Radio Protocol SRP Administration GuideSpectraLink 8000 Telephony Gateway Copyright Notice Trademark InformationPatent Information Contact InformationReferenced Documents About This GuidePolycom Model Numbers SpectraLink 8000 SVP Server Administration Guide for SRPDeploying Enterprise-Grade Wi-Fi Telephony Customer SupportIcons and Conventions Best Practices Guide for Deploying SpectraLink 8020/8030 WirelessInstallation and Configuration Steps ContentsTelephone Interface Configuration Site Preparation7 SpectraLink 8000 Telephony Gateway Administration 5 Pre-Installation Verification6 Install SpectraLink 8000 Telephony Gateway 8 Connecting to the SpectraLink 8000 TelephonyTelephone Line Configuration Network ConfigurationSet or Change Password Features Programming MenuIndex Troubleshooting via the System Status MenuSafety Notices Wireless Device Planning WorksheetSpectraLink Overview System ArchitectureSpectraLink Voice Priority SVP and Quality of Service System TimingSystem Components SpectraLink Wireless TelephonesSystem Speed SpectraLink 8000 Telephony GatewayRouter Access pointsEthernet switch Administrative computer SpectraLink 8000 SVP ServerSystem Diagram Ethernet switchThe Front Panel of the SpectraLink 8000 Telephony Gateway 4 Timing Master Installation and Configuration Steps ConditionalPage Site Preparation Required MaterialsGrounding materials per section below Grounding Instructions IP addressing LAN RequirementsNetwork infrastructure Location of SpectraLink 8000 Telephony Gateway and SVP Server Prepare Demarcation Demarc Blocks Telephone Interface ConfigurationModem administration SpectraLink 8000 Telephony Gateway Administration Guide Connect Telephone Lines to Demarc Blocks Install Telephone Demarc BlocksAssign and Program Telephone Ports Telephone Ports Two-wire analog or digital demarc block25 PAIR MALE CONNECTOR CABLE TO GATEWAY CONNECTOR A TX denotes data transmitted from the telephone system to the Gateway Four-wire digital demarc block Connector ATelephone Ports Telephone Four-wire digital demarc block Connector B25 PAIR MALE CONNECTOR CABLE TO GATEWAY CONNECTOR B PortsCheck Components Pre-Installation VerificationVerify Pre-Installation Requirements Page Connector A is… Install SpectraLink 8000 Telephony GatewayMount to Rack or Wall To MountMount the SpectraLink 8000 Telephony Gateway to wall SafetyMount the SpectraLink 8000 Telephony Gateway to rack Grounding instructionsAll system units must be grounded to a protective earth by means of the grounding stud located on the rear panel. Refer to the illustration below for recommended continuity connection Mount Gateway Installing Multiple SpectraLink 8000 Telephony GatewaysInstall bonding straps Install IPC cables Connect SpectraLink 8000 Telephony Gateway to Demarc Blocks Connect powerConnect five or more SpectraLink 8000 Telephony Gateways Connect SpectraLink 8000 Telephony Gateway to LANStatus 1 should be blinking on each SpectraLink 8000 Telephony Gateway Page SpectraLink 8000 Telephony Gateway Administration Overview SpectraLink 8000 Telephony Gateway Administration Guide SpectraLink 8000 Telephony Gateway Configuration Sequence Send All 11. Perform AP coverage test per Certifying the Wireless TelephonesPress Navigating through the Administration Console ScreensTo Perform this Function Page Connecting to the SpectraLink 8000 Telephony Gateway Connect via the Serial PortSelect a SpectraLink 8000 Telephony Gateway to Administer If using a serial connection, only the SpectraLink 8000 Telephony Gateway that is connected via the serial cable is shown 5. Unplug the serial cable Connecting via Telnet Connecting via External ModemConfigure modem internal settings US Robotics Sportster Connecting via Internal Modem Connect the modemPage Function Main MenuMenu Option Page Network Configuration Subnet Mask The network administrator must define the subnet mask correct setting from the DHCP server. The DHCP setting is only valid when the IP address is also acquired using DHCP Press Esc to return to the SpectraLink 8000 System menu Set or Change Password Page SpectraLink 8000 Telephony Gateway Configuration OAI hostname Valid entries Valid source location entries are Press Esc to return to the NetLink Wireless Telephone System menu Reset the SpectraLink 8000 Telephony Gateway Page Telephone Line Configuration Adding or Changing a Handset3. Write the MAC address on the Wireless Planning Device Worksheet 3. Press D to delete the handset information Deleting a Handset2. Use the arrow keys to highlight the line to be deleted 4. Press Y to accept changesPage Features Programming Menu Page Feature Programming no Softkeys Interface Guide for your system Programming Digital PBX FeaturesProgramming Analog PBX Features 3. Type F to assign the FLASH function Programming the ADMIN Feature Menu Programming no softkeys To change the menu settings 4. Repeat for each menu as needed Page Softkey and Shortcut Key Programming Sample screen Scroll to remaining options Speakerphone softkey programming SpectraLink 8020/8030 only Softkey Label Software Maintenance Software UpdatesUpdating Larger Systems Using FTPFTP procedure To transfer the software using FTP Updating Wireless Telephone Software Normal download messagesBackup and Restore SpectraLink 8000 Telephony Gateway Configuration Download failure or recovery messagesget config.bin gateway1.bin Troubleshooting via the System Status Menu Error Status Displays alarm and error message information Access Point Status D is day, HH is hours, MM is minutes, and SS is seconds Error StatusUnless noted otherwise, times are displayed using the format Alarm Error DescriptionReset = reset SpectraLink 8000 Telephony Gateway Alarm 1 SpectraLink Radio Protocol See Network Status section Network Status RX Broadcast The number of broadcast packets and bytes received Telephone Line Status Wireless Telephone Status WT MAC The MAC address of the handset Software Version Wireless Telephones per AP Wireless Device Planning WorksheetHost Switch Type Switch Port ID IP AddressSpectraLink 8000 Telephony Gateway Administration Guide Safety Notices Page Index