Install Telephone Demarc Blocks

Telephone Interface Configuration

Install Telephone Demarc Blocks

The demarcation blocks used to connect the telephone system to the Telephony Gateway should be installed on 3/4” telephone facility backboard. Although this manual uses 66-blocks as examples, any standard cross-connect blocks are acceptable.

Assign and Program Telephone Ports

The wire contractor should inform the system administrator which telephone line numbers have been designated for the wireless devices and the remote diagnostics modem line.

The system administrator must assign extension numbers associated with the wireless devices and plan the functions (trunk access, toll restrictions, system features, ringing options, etc.) to be programmed. This programming will be done after the wireless devices are assigned to the SpectraLink 8000 Telephony Gateway, but will be faster if planned in advance by verifying the parameters and features on the current telephone system and wired phones.

For more detail, consult the Polycom LinkPlus Digital Interface document for the type of telephone system in use at your location.

Connect Telephone Lines to Demarc Blocks

Telephone cables are punched down onto the cross-connect blocks as shown in the following demarc block diagrams.

Photocopy the Wireless Device Planning Worksheets as needed. Use the forms to track the telephone line assignments connected to each SpectraLink 8000 Telephony Gateway. As the installer punches down each telephone connection, record the information on the form to identify the user and extension assigned. A copy of this form should be posted near the cross-connect block.

PN: 1725-36028-001_T.doc

25

Image 25
Contents SpectraLink 8000 Telephony Gateway Administration GuideUtilizing SpectraLink Radio Protocol SRP Patent Information Trademark InformationCopyright Notice Contact InformationPolycom Model Numbers About This GuideReferenced Documents SpectraLink 8000 SVP Server Administration Guide for SRPIcons and Conventions Customer SupportDeploying Enterprise-Grade Wi-Fi Telephony Best Practices Guide for Deploying SpectraLink 8020/8030 WirelessTelephone Interface Configuration ContentsInstallation and Configuration Steps Site Preparation6 Install SpectraLink 8000 Telephony Gateway 5 Pre-Installation Verification7 SpectraLink 8000 Telephony Gateway Administration 8 Connecting to the SpectraLink 8000 TelephonySet or Change Password Network ConfigurationTelephone Line Configuration Features Programming MenuSafety Notices Troubleshooting via the System Status MenuIndex Wireless Device Planning WorksheetSystem Architecture SpectraLink OverviewSystem Timing SpectraLink Voice Priority SVP and Quality of ServiceSystem Speed SpectraLink Wireless TelephonesSystem Components SpectraLink 8000 Telephony GatewayEthernet switch Access pointsRouter SpectraLink 8000 SVP Server Administrative computerEthernet switch System DiagramThe Front Panel of the SpectraLink 8000 Telephony Gateway 4 Timing Master Conditional Installation and Configuration StepsPage Required Materials Site PreparationGrounding materials per section below Grounding Instructions Network infrastructure LAN RequirementsIP addressing Location of SpectraLink 8000 Telephony Gateway and SVP Server Modem administration Telephone Interface ConfigurationPrepare Demarcation Demarc Blocks PN 1725-36028-001T.doc Assign and Program Telephone Ports Install Telephone Demarc BlocksConnect Telephone Lines to Demarc Blocks 25 PAIR MALE CONNECTOR CABLE TO GATEWAY CONNECTOR A Two-wire analog or digital demarc blockTelephone Ports Telephone Ports Four-wire digital demarc block Connector ATX denotes data transmitted from the telephone system to the Gateway 25 PAIR MALE CONNECTOR CABLE TO GATEWAY CONNECTOR B Four-wire digital demarc block Connector BTelephone PortsVerify Pre-Installation Requirements Pre-Installation VerificationCheck Components Page Mount to Rack or Wall Install SpectraLink 8000 Telephony GatewayConnector A is… To MountMount the SpectraLink 8000 Telephony Gateway to rack SafetyMount the SpectraLink 8000 Telephony Gateway to wall Grounding instructionsAll system units must be grounded to a protective earth by means of the grounding stud located on the rear panel. Refer to the illustration below for recommended continuity connection Install bonding straps Installing Multiple SpectraLink 8000 Telephony GatewaysMount Gateway Install IPC cables Connect five or more SpectraLink 8000 Telephony Gateways Connect powerConnect SpectraLink 8000 Telephony Gateway to Demarc Blocks Connect SpectraLink 8000 Telephony Gateway to LANStatus 1 should be blinking on each SpectraLink 8000 Telephony Gateway Page SpectraLink 8000 Telephony Gateway Administration Overview PN 1725-36028-001T.doc SpectraLink 8000 Telephony Gateway Configuration Sequence 11. Perform AP coverage test per Certifying the Wireless Telephones Send AllTo Perform this Function Navigating through the Administration Console ScreensPress Page Connect via the Serial Port Connecting to the SpectraLink 8000 Telephony GatewaySelect a SpectraLink 8000 Telephony Gateway to Administer If using a serial connection, only the SpectraLink 8000 Telephony Gateway that is connected via the serial cable is shown 5. Unplug the serial cable Connecting via External Modem Connecting via TelnetConfigure modem internal settings US Robotics Sportster Connect the modem Connecting via Internal ModemPage Menu Option Main MenuFunction Page Network Configuration Subnet Mask The network administrator must define the subnet mask correct setting from the DHCP server. The DHCP setting is only valid when the IP address is also acquired using DHCP Press Esc to return to the SpectraLink 8000 System menu Set or Change Password Page SpectraLink 8000 Telephony Gateway Configuration OAI hostname Valid entries Valid source location entries are Press Esc to return to the NetLink Wireless Telephone System menu Reset the SpectraLink 8000 Telephony Gateway Page Adding or Changing a Handset Telephone Line Configuration3. Write the MAC address on the Wireless Planning Device Worksheet 2. Use the arrow keys to highlight the line to be deleted Deleting a Handset3. Press D to delete the handset information 4. Press Y to accept changesPage Features Programming Menu Page Feature Programming no Softkeys Programming Analog PBX Features Programming Digital PBX FeaturesInterface Guide for your system 3. Type F to assign the FLASH function Programming the ADMIN Feature Menu Programming no softkeys To change the menu settings 4. Repeat for each menu as needed Page Softkey and Shortcut Key Programming Sample screen Scroll to remaining options Speakerphone softkey programming SpectraLink 8020/8030 only Softkey Label Software Updates Software MaintenanceFTP procedure Using FTPUpdating Larger Systems To transfer the software using FTP Normal download messages Updating Wireless Telephone SoftwareDownload failure or recovery messages Backup and Restore SpectraLink 8000 Telephony Gateway Configurationget config.bin gateway1.bin Troubleshooting via the System Status Menu Error Status Displays alarm and error message information Access Point Status Unless noted otherwise, times are displayed using the format Error StatusD is day, HH is hours, MM is minutes, and SS is seconds Error Description AlarmReset = reset SpectraLink 8000 Telephony Gateway Error Description 1 SpectraLink Radio Protocol See Network Status section Network Status RX Broadcast The number of broadcast packets and bytes received Telephone Line Status Wireless Telephone Status WT MAC The MAC address of the handset Software Version Host Switch Type Wireless Device Planning WorksheetWireless Telephones per AP Switch Port ID IP AddressPN 1725-36028-001T.doc Safety Notices Page Index