Delta user manual PD-01 PROFIBUS-DP Module

Page 27

PD-01 PROFIBUS-DP Module

Unsigned16 0x2000 0-65535

EndExtUserPrmData

ExtUserPrmData = 2 "Data Input 2"

Unsigned16 0x2001 0-65535

EndExtUserPrmData

ExtUserPrmData = 3 "Data Input 3"

Unsigned16 0x0000 0-65535

EndExtUserPrmData

ExtUserPrmData = 4 "Data Input 4"

Unsigned16 0x0000 0-65535

EndExtUserPrmData

ExtUserPrmData = 5 "Data Output 1(VFD -> PD-01)"

Unsigned16 0x2101 0-65535

EndExtUserPrmData

ExtUserPrmData = 6 "Data Output 2"

Unsigned16 0x2102 0-65535

EndExtUserPrmData

ExtUserPrmData = 7 "Data Output 3"

Unsigned16 0x2103 0-65535

EndExtUserPrmData

ExtUserPrmData = 8 "Data Output 4"

Unsigned16 0x2104 0-65535

EndExtUserPrmData

ExtUserPrmData = 9 "d_state"

Unsigned16 1 0-1

Prm_Text_Ref = 1

EndExtUserPrmData

ExtUserPrmData = 10 "din_len"

Unsigned16 2 0-4

EndExtUserPrmData

ExtUserPrmData = 11 "dout_len"

Unsigned16 2 0-4

EndExtUserPrmData

ExtUserPrmData = 12 "LossDPComTreat"

Unsigned16 1 0-1

Prm_Text_Ref = 2

EndExtUserPrmData

24DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Image 27
Contents PROFIBUS-DP Module for VFD Series Drives Table of Contents Chapter Troubleshooting Chapter User Parameters Setting in GSD filePreface VFD-M Using this ManualReceiving and Inspection Delta AC Drive Firmware VersionSP LED NET LED OverviewFunctionality Technical informationProfibus IntroductionPROFIBUS-DP Installing the PD-01 InstallationRJ11 Dgnd Removing the PD-01Pin assignment of PROFIBUS-DP interface DB9 TerminatorA1 S B1 121ohm Parameters setting in VFD series Drives CommunicationProfibus address Extended configuration Cyclical data of PD-01 via PROFIBUS-DPUseful data structure as defined in PROFIDrive Profile Control and Status words Default settings of PZD structureStatus word data from VFD series Drives to DP Accessing parameters via PKW area Request Identifier MeaningResponse Identifier Meaning PKE IND PWE1 PWE2 High LOW PNUParameter value PWE 3rd and 4th word PKE Examples for PKW mechanism1034 VFD Response time about PD-01Max update time = T1 + T2 70ms + T3 = Vfddrv User Parameters Setting in GSD fileGSD file = VFD DrivesOrdernumber PZD PD-01 PROFIBUS-DP Module Uint User parameters in GSD fileName Type Description Default Data Input Name Type Description Default LossSPComTreat PD-01 PROFIBUS-DP Module OFF TroubleshootingTroubleshooting via LED displays LEDTroubleshooting via diagnostic data Code Meaning Corrective actives Troubleshooting via error codesCode Meaning Corrective actives Dimensions