PD-01 PROFIBUS-DP Module

Receiving and Inspection

All Delta PD-01 have gone through rigorous quality control tests at the factory prior to the shipment. Upon the receive of PD-01, please check that the package includes:

1pcs PD-01,

1pcs 8cm disc (mini size compact disc),

1pcs communication cable (for RJ11, 6 pins),

1 instruction sheet

Using this Manual

This is the User Manual for PD-01.

Chapter 1 describes the overview of PD-01

Chapter 2 briefly describes the introduction to PROFIBUS and PROFIBUS-DP

Chapter 3 introduces how to install and remove the PD-01

Chapter 4 describes the communication with PROFIBUS-DP system

Chapter 5 introduces GSD file and parameter settings in GSD file of PD-01

Chapter 6 provides LEDs information, and corrective actions for problem solving.

Chapter 7 provides the dimensions of the PD-01

Firmware version should conform with VFD Drives as table below:

Delta AC Drive

Firmware Version

VFD-B

Version 4.00 and above

VFD-M

Version 3.00and above

VFD-F

Version 1.09 and above

VFD-L

 

115V/200~400W

All Version

230V/200W~2HP

 

VFD-S

All Version

2DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Image 5
Contents PROFIBUS-DP Module for VFD Series Drives Table of Contents Chapter Troubleshooting Chapter User Parameters Setting in GSD filePreface Receiving and Inspection Using this ManualDelta AC Drive Firmware Version VFD-MSP LED NET LED OverviewFunctionality Technical informationProfibus IntroductionPROFIBUS-DP Installing the PD-01 InstallationRJ11 Pin assignment of PROFIBUS-DP interface DB9 Removing the PD-01Terminator DgndA1 S B1 121ohm Profibus address Parameters setting in VFD series DrivesCommunication Useful data structure as defined in PROFIDrive Profile Extended configurationCyclical data of PD-01 via PROFIBUS-DP Control and Status words Default settings of PZD structureStatus word data from VFD series Drives to DP Response Identifier Meaning Accessing parameters via PKW areaRequest Identifier Meaning Parameter value PWE 3rd and 4th word PKE IND PWE1 PWE2 High LOWPNU PKE Examples for PKW mechanism1034 VFD Response time about PD-01Max update time = T1 + T2 70ms + T3 GSD file User Parameters Setting in GSD file= VFD Drives = VfddrvOrdernumber PZD PD-01 PROFIBUS-DP Module Uint User parameters in GSD fileName Type Description Default Data Input Name Type Description Default LossSPComTreat PD-01 PROFIBUS-DP Module Troubleshooting via LED displays TroubleshootingLED OFFTroubleshooting via diagnostic data Code Meaning Corrective actives Troubleshooting via error codesCode Meaning Corrective actives Dimensions