Delta PD-01 user manual User parameters in GSD file, Uint

Page 28

PD-01 PROFIBUS-DP Module

ExtUserPrmData = 13 "LossSPComTreat"

Unsigned16 0 0-2

Prm_Text_Ref = 3

EndExtUserPrmData

Ext_User_Prm_Data_Ref(0) = 1

Ext_User_Prm_Data_Ref(2) = 2

Ext_User_Prm_Data_Ref(4) = 3

Ext_User_Prm_Data_Ref(6) = 4

Ext_User_Prm_Data_Ref(8) = 5

Ext_User_Prm_Data_Ref(10) = 6

Ext_User_Prm_Data_Ref(12) = 7

Ext_User_Prm_Data_Ref(14) = 8

Ext_User_Prm_Data_Ref(16) = 9

Ext_User_Prm_Data_Ref(18) = 10

Ext_User_Prm_Data_Ref(20) = 11

Ext_User_Prm_Data_Ref(22) = 12

Ext_User_Prm_Data_Ref(24) = 13

File END: ==========================================================

NOTE:

The required GSD file is available and can be downloaded from the DELTA web site http://www.delta.com.tw, or you can copy this text to a text editor such as NOTEPAD, and save it as a GSD file named “DELT08DB.GSD”. Please make sure to specify the file name extension as “.GSD”, PLEASE DO NOT SAVE IT extension “.GSD.TXT”.

User parameters in GSD file

The user parameters in GSD file are used for the configuration of the PROFIBUS network. The description of the user parameters are shown in the following table:

 

Item

Name

Type

 

Description

Default

 

 

1

Data Input 1

UINT

This is a MODBUS address. The 1st word in

0x2000

 

 

 

 

 

PZD of cyclic output data will be sent to this

 

 

 

 

 

 

address.

 

 

 

 

2

Data Input 2

UINT

This is a MODBUS address. The 2nd word in

0x2001

 

 

 

 

 

PZD of cyclic output data will be sent to this

 

 

 

 

 

 

address.

 

 

 

 

 

 

 

 

 

 

 

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

25

 

 

Image 28
Contents PROFIBUS-DP Module for VFD Series Drives Table of Contents Chapter User Parameters Setting in GSD file Chapter TroubleshootingPreface Using this Manual Receiving and InspectionDelta AC Drive Firmware Version VFD-MOverview SP LED NET LEDTechnical information FunctionalityIntroduction ProfibusPROFIBUS-DP Installation Installing the PD-01RJ11 Removing the PD-01 Pin assignment of PROFIBUS-DP interface DB9Terminator DgndA1 S B1 121ohm Communication Parameters setting in VFD series DrivesProfibus address Cyclical data of PD-01 via PROFIBUS-DP Extended configurationUseful data structure as defined in PROFIDrive Profile Default settings of PZD structure Control and Status wordsStatus word data from VFD series Drives to DP Request Identifier Meaning Accessing parameters via PKW areaResponse Identifier Meaning PNU PKE IND PWE1 PWE2 High LOWParameter value PWE 3rd and 4th word Examples for PKW mechanism PKE1034 Response time about PD-01 VFDMax update time = T1 + T2 70ms + T3 User Parameters Setting in GSD file GSD file= VFD Drives = VfddrvOrdernumber PZD PD-01 PROFIBUS-DP Module User parameters in GSD file UintName Type Description Default Data Input Name Type Description Default LossSPComTreat PD-01 PROFIBUS-DP Module Troubleshooting Troubleshooting via LED displaysLED OFFTroubleshooting via diagnostic data Troubleshooting via error codes Code Meaning Corrective activesCode Meaning Corrective actives Dimensions