PD-01 PROFIBUS-DP Module
Item | Name | Type |
| Description | Default |
13 | LossSPComTreat | UINT | This variable indicates that the | 0x0000 | |
|
|
| take action when the SP communication |
| |
|
|
| (SCANport communication) is lost, the value |
| |
|
|
| can be assigned as follows: |
| |
|
|
| 00 | – Stop data exchange and report fault; |
|
|
|
| 01 | – Continue data exchange and report |
|
|
|
|
| alarm; |
|
|
|
| 02 | – Ignore and continue data exchange. |
|
If the address in Data Output 1 ~ Data Output 4 is continuous, then set d_state to 1,
Example, if |
|
Data Output 1 | = 0x2100; |
Data Output 2 | = 0x2101; |
Data Output 3 | = 0x2102; |
Data Output 4 | = 0x2103; |
dout_len = 0x0003;
The MODBUS address in Data Output 1~Data Output 4 is continuous, so you can set the d_state to 1, then