Seagate DL585 manual Ppm

Page 11

Table 2

System components spare parts list

 

 

 

 

Item

Description

Assembly

Modified

Spare part

Modified spare

Customer self-

 

 

number

assembly

number

part number

repair (Yes/No)

 

 

 

number

 

 

 

 

 

 

 

 

 

 

8

Processor memory boards

 

 

 

 

 

 

 

Processor memory board

011974-002‡

011974-502

356783-001

Yes

 

(PC2100/PC2700)**

See requirement

 

 

 

 

 

 

 

 

 

 

 

Processor memory board

011974-003‡

011974-503

382596-001‡

412319-001

Yes

 

(PC2100/PC2700)**

See requirement

 

See requirement

 

 

 

 

 

 

 

 

 

Processor memory board

012567-001‡

012567-501

378476-001‡

412321-001

Yes

 

(PC3200)**

See requirement

 

See requirement

 

 

 

 

 

 

 

 

 

9

Processors

 

 

 

 

 

 

 

Processor, Opteron 850,

391162-001

382043-001

Yes

 

2.6 GHz

 

 

 

 

 

 

 

 

 

 

 

 

Processor, 2.8 GHz

397805-001

399203-01

Yes

 

 

 

 

 

 

 

Processor, dual core, 1.8

389711-001

390247-001

Yes

 

GHz

 

 

 

 

 

 

 

 

 

 

 

 

Processor, dual core, 2.2

389711-003

390249-001

Yes

 

GHz

 

 

 

 

 

 

 

 

 

 

 

 

Processor, dual core, 2.4

389711-004

403836-001

Yes

 

GHz

 

 

 

 

 

 

 

 

 

 

 

 

Processor, dual core, 2.6

389711-005

410873-001

Yes

 

GHz

 

 

 

 

 

 

 

 

 

 

 

 

10

Heatsink

321961-007

383420-001

Yes

 

 

 

 

 

 

 

11

Processor power module

383265-001

383337-001

Yes

 

(PPM)

 

 

 

 

 

 

 

 

 

 

 

 

12

Cable kit

243670-001

Yes

 

 

 

 

 

 

 

U320 SCSI cable

166298-003

Yes

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

U320 SCSI cable

166298-039

Yes

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

Power cable assembly

233303-001

Yes

 

 

 

 

 

 

 

Hot-plug cable assembly

241793-012

Yes

 

 

 

 

 

 

 

13

Battery, system, 3 V

166899-001

153099-001

Yes

 

 

 

 

 

 

 

14

5i Plus cache memory

011665-001

260741-001

Yes

 

module

 

 

 

 

 

 

 

 

 

 

 

 

15

Battery-Backed Write

011668-001

260740-001

Yes

 

Cache Module (BBWC),

 

 

 

 

 

 

4.8 V

 

 

 

 

 

 

 

 

 

 

 

 

16

BBWC cache module

262695-

283033-001

Yes

 

cable*

004/005

 

 

 

 

 

 

 

 

 

 

 

17

Fan assembly, hot-plug,

321520-001

359773-001

Yes

 

92 x 38 mm

 

 

 

 

 

 

 

 

 

 

 

 

18

Fan cage cable

321518-001

361442-001

No

 

assembly*

 

 

 

 

 

 

 

 

 

 

 

 

19

SAS backplane kit*

376475-001‡

411794-001

Yes

 

 

 

 

See requirement

 

 

 

 

 

 

 

 

 

SAS backplane board *

012564-001‡

012564-501

Yes

 

 

See requirement

 

 

 

 

 

 

 

 

 

 

 

Illustrated parts catalog 11

Image 11
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce Technician notes Where to go for additional helpAbout this guide Audience assumptionsTelephone numbers Integrated Management LogCustomer self-repair program Illustrated parts catalogMechanical components exploded view Mechanical components spare parts list‡REQUIREMENT System components exploded view System components spare parts listPPM Sdram ‡REQUIREMENT Electrostatic discharge Removal and replacement proceduresSafety considerations Preparation proceduresPowering down the server Extending the server from the rack Locating and removing the Torx T-15 toolRemoval and replacement procedures Installing the access panel Removing the access panelRemoving the server from the rack Processor memory board population guidelines Processor memory boardsPPM Removing a processor ProcessorRemoval and replacement procedures Minimum memory requirements Memory optionsRemoving a Dimm Hot-plug Scsi hard drives Drive replacement precautionsHard drive blanks Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Universal media drives Hot-plug fansRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards PCI-X expansion boards Performance balancingScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane Locating the battery on the system board System batteryRemove the existing battery System board Removal and replacement procedures Cutting the cable tie-wraps AC filter cable assemblyRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Rear panel ConnectorsServer component identification Scsi backplane Scsi backplane board connectorsProcessor and PPM Dimm slotsFront panel LEDsHP ProLiant DL585 Server User Guide on QuickFind diagnostic displayHot-plug Scsi hard drive LEDs Hot-plug Scsi hard drivesHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drive LED combinations Hot-plug SAS or Sata hard drivesHot-plug SAS or Sata hard drive LED combinations Hot-plug fans Hot-plug power suppliesNIC Bbwce Internal diagnostic display System maintenance switch SW3 System board switchesSystem ID switch SW4 System ID Switch SW4 System ID switch SW4ILO/Redundant ROM override switch SW5 Rear unit identification LED switch Non-maskable interrupt switchTroubleshooting If the server does not start Is the system power LED off? Diagnostic stepsIs the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Four-processor memory board configuration Troubleshooting a failed processorTwo-processor memory board configuration Other information resources Server specifications SpecificationsIndex UID LED