Seagate DL585 manual Specifications, Server specifications

Page 84

Specifications

Server specifications

Table 35 Server specifications

Feature

Units

 

 

Dimensions

 

 

 

Height

17.5 cm (6.88 in)

 

 

Depth

69.2 cm (27.25 in)

 

 

Width

46.3 cm (19.0 in)

 

 

Weight

30.8 kg, minimum (68 lb, minimum)

44.5 kg, maximum (98 lb, maximum)

 

 

 

High-line voltage requirements

 

 

 

Rated input voltage

180 V to 264 V

 

 

Rated input frequency

47 Hz to 63 Hz

 

 

Rated input current

6 A

 

 

Low-line voltage requirements

 

 

 

Rated input voltage

90 V to 132 V

 

 

Rate input frequency

47 Hz to 63 Hz

 

 

Rated input current

12 A

 

 

Power supply output power

 

 

 

Rated steady-state power

800 W

 

 

Maximum peak power

800 W

 

 

Temperature range

 

 

 

Operating

10° to 35°C (50° to 95°F)

 

 

Non-operating

-30°to 60°C (-20°to 140°F)

 

 

Relative humidity (non-condensing)

 

 

 

Operating

20% to 80%

 

 

Non-operating

5% to 90%

 

 

Maximum wet bulb temperature

38.7°C (101.7°F)

 

 

Heat dissipation

3900 BTU/hr

 

 

Specifications 84

Image 84
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce Where to go for additional help About this guideAudience assumptions Technician notesIntegrated Management Log Telephone numbersIllustrated parts catalog Customer self-repair programMechanical components spare parts list Mechanical components exploded view‡REQUIREMENT System components spare parts list System components exploded viewPPM Sdram ‡REQUIREMENT Removal and replacement procedures Safety considerationsPreparation procedures Electrostatic dischargePowering down the server Locating and removing the Torx T-15 tool Extending the server from the rackRemoval and replacement procedures Removing the access panel Installing the access panelRemoving the server from the rack Processor memory boards Processor memory board population guidelinesPPM Processor Removing a processorRemoval and replacement procedures Memory options Minimum memory requirementsRemoving a Dimm Drive replacement precautions Hard drive blanksHot-plug Scsi hard drives Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Hot-plug fans Universal media drivesRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards Performance balancing PCI-X expansion boardsScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane System battery Locating the battery on the system boardRemove the existing battery System board Removal and replacement procedures AC filter cable assembly Cutting the cable tie-wrapsRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Connectors Server component identificationRear panel Scsi backplane board connectors Scsi backplaneDimm slots Processor and PPMLEDs Front panelQuickFind diagnostic display HP ProLiant DL585 Server User Guide onHot-plug Scsi hard drives Hot-plug Scsi hard drive LEDsHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drives Hot-plug SAS or Sata hard drive LED combinationsHot-plug SAS or Sata hard drive LED combinations Hot-plug power supplies Hot-plug fansNIC Bbwce Internal diagnostic display System board switches System maintenance switch SW3System ID switch SW4 System ID switch SW4 System ID Switch SW4ILO/Redundant ROM override switch SW5 Non-maskable interrupt switch Rear unit identification LED switchTroubleshooting If the server does not start Diagnostic steps Is the system power LED off?Is the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Troubleshooting a failed processor Two-processor memory board configurationFour-processor memory board configuration Other information resources Specifications Server specificationsIndex UID LED