Seagate DL585 manual Mechanical components exploded view, Mechanical components spare parts list

Page 8

Mechanical components exploded view

Figure 1 Mechanical components exploded view

Mechanical components spare parts list

Table 1

Mechanical components spare parts list

 

 

 

 

Item

Description

Assembly

Modified

Spare part

Modified spare

Customer self-

 

 

number

assembly

number

part number

repair (Yes/No)

 

 

 

number

 

 

 

 

 

 

 

 

 

 

1

Access panel

321466-001

359772-001

Yes

 

 

 

 

 

 

 

2

Front bezel

233588-002

243669-001

Yes

 

 

 

 

 

 

 

3

SCSI hard drive blank

302531-002

122759-001

Yes

 

 

 

 

 

 

 

4

Hard drives

 

 

 

 

 

 

 

36-GB SCSI hard drive,

271837-016‡

404670-008

289241-001‡

404714-001

Yes

 

U320 15K*

See requirement

 

See requirement

 

 

 

 

 

 

 

 

 

72-GB SCSI hard drive,

271837-008‡

404670-003

289042-001‡

404709-001

Yes

 

U320 10K*

See requirement

 

See requirement

 

 

 

 

 

 

 

 

 

72-GB SCSI hard drive,

271837-018‡

404670-007

289243-001‡

404713-001

Yes

 

U320 15K*

See requirement

 

See requirement

 

 

 

 

 

 

 

 

 

Illustrated parts catalog 8

Image 8
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce Where to go for additional help About this guideAudience assumptions Technician notesIntegrated Management Log Telephone numbersIllustrated parts catalog Customer self-repair programMechanical components spare parts list Mechanical components exploded view‡REQUIREMENT System components spare parts list System components exploded viewPPM Sdram ‡REQUIREMENT Removal and replacement procedures Safety considerationsPreparation procedures Electrostatic dischargePowering down the server Locating and removing the Torx T-15 tool Extending the server from the rackRemoval and replacement procedures Removing the access panel Installing the access panelRemoving the server from the rack Processor memory boards Processor memory board population guidelinesPPM Processor Removing a processorRemoval and replacement procedures Memory options Minimum memory requirementsRemoving a Dimm Hot-plug Scsi hard drives Drive replacement precautionsHard drive blanks Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Hot-plug fans Universal media drivesRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards Performance balancing PCI-X expansion boardsScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane System battery Locating the battery on the system boardRemove the existing battery System board Removal and replacement procedures AC filter cable assembly Cutting the cable tie-wrapsRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Rear panel ConnectorsServer component identification Scsi backplane board connectors Scsi backplaneDimm slots Processor and PPMLEDs Front panelQuickFind diagnostic display HP ProLiant DL585 Server User Guide onHot-plug Scsi hard drives Hot-plug Scsi hard drive LEDsHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drives Hot-plug SAS or Sata hard drive LED combinationsHot-plug SAS or Sata hard drive LED combinations Hot-plug power supplies Hot-plug fansNIC Bbwce Internal diagnostic display System board switches System maintenance switch SW3System ID switch SW4 System ID switch SW4 System ID Switch SW4ILO/Redundant ROM override switch SW5 Non-maskable interrupt switch Rear unit identification LED switchTroubleshooting If the server does not start Diagnostic steps Is the system power LED off?Is the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Four-processor memory board configuration Troubleshooting a failed processorTwo-processor memory board configuration Other information resources Specifications Server specificationsIndex UID LED