1 About this guide

This maintenance and service guide can be used for reference when servicing the HP ProLiant DL585 Server.

WARNING! To reduce the risk of personal injury from electric shock and hazardous energy levels, only authorized service technicians should attempt to repair this equipment. Improper repairs can create conditions that are hazardous.

Audience assumptions

This guide is for service technicians. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazard in products with hazardous energy levels and are familiar with weight and stability precautions for rack installations.

Technician notes

WARNING! Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.

WARNING! To reduce the risk of personal injury from electric shock and hazardous energy levels, do not exceed the level of repairs specified in these procedures. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create conditions that are hazardous.

WARNING! To reduce the risk of electric shock or damage to the equipment:

Disconnect power from the system by unplugging all power cords from the power supplies.

Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.

CAUTION: The computer is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.

NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty.

Where to go for additional help

In addition to this guide, the following information sources are available:

User documentation

Service Quick Reference Guide

Service training guides

Service advisories and bulletins

QuickFind information services

HP Systems Insight Manager (HP SIM) software

About this guide 5

Image 5
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce About this guide Where to go for additional helpAudience assumptions Technician notesTelephone numbers Integrated Management LogCustomer self-repair program Illustrated parts catalogMechanical components exploded view Mechanical components spare parts list‡REQUIREMENT System components exploded view System components spare parts listPPM Sdram ‡REQUIREMENT Safety considerations Removal and replacement proceduresPreparation procedures Electrostatic dischargePowering down the server Extending the server from the rack Locating and removing the Torx T-15 toolRemoval and replacement procedures Installing the access panel Removing the access panelRemoving the server from the rack Processor memory board population guidelines Processor memory boardsPPM Removing a processor ProcessorRemoval and replacement procedures Minimum memory requirements Memory optionsRemoving a Dimm Hot-plug Scsi hard drives Drive replacement precautionsHard drive blanks Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Universal media drives Hot-plug fansRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards PCI-X expansion boards Performance balancingScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane Locating the battery on the system board System batteryRemove the existing battery System board Removal and replacement procedures Cutting the cable tie-wraps AC filter cable assemblyRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Rear panel ConnectorsServer component identification Scsi backplane Scsi backplane board connectorsProcessor and PPM Dimm slotsFront panel LEDsHP ProLiant DL585 Server User Guide on QuickFind diagnostic displayHot-plug Scsi hard drive LEDs Hot-plug Scsi hard drivesHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drive LED combinations Hot-plug SAS or Sata hard drivesHot-plug SAS or Sata hard drive LED combinations Hot-plug fans Hot-plug power suppliesNIC Bbwce Internal diagnostic display System maintenance switch SW3 System board switchesSystem ID switch SW4 System ID Switch SW4 System ID switch SW4ILO/Redundant ROM override switch SW5 Rear unit identification LED switch Non-maskable interrupt switchTroubleshooting If the server does not start Is the system power LED off? Diagnostic stepsIs the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Four-processor memory board configuration Troubleshooting a failed processorTwo-processor memory board configuration Other information resources Server specifications SpecificationsIndex UID LED