Seagate DL585 manual Pass-through board

Page 41

Pass-through board

To remove the pass-through board:

1.Power down the server. See “Powering down the server” earlier in this chapter.

2.Extend the server from the rack. See “Extending the server from the rack” earlier in this chapter.

3.Remove the access panel. See “Removing the access panel” earlier in this chapter.

4.Remove the processor memory boards. See “Processor memory boards” earlier in this chapter.

5.Remove the PCI-X expansion boards. See “PCI-X expansion boards” earlier in this chapter.

6.Remove the SCSI cables. See “SCSI cables” earlier in this chapter.

7.Remove the front fan cage. See “Front fan cage” earlier in this chapter.

8.Loosen the two thumbscrews that secure the pass-through board to the diagnostic display board and the side chassis wall . You might need to use a Torx T-15 screwdriver.

9.Lift the pass-through board straight up and out of the chassis .

Figure 37 Removing the pass-through board

Reverse the steps to replace the pass-through board.

NOTE: Align the board with connectors on both ends and press simultaneously when installing.

Removal and replacement procedures 41

Image 41
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce About this guide Where to go for additional helpAudience assumptions Technician notesTelephone numbers Integrated Management LogCustomer self-repair program Illustrated parts catalogMechanical components exploded view Mechanical components spare parts list‡REQUIREMENT System components exploded view System components spare parts listPPM Sdram ‡REQUIREMENT Safety considerations Removal and replacement proceduresPreparation procedures Electrostatic dischargePowering down the server Extending the server from the rack Locating and removing the Torx T-15 toolRemoval and replacement procedures Installing the access panel Removing the access panelRemoving the server from the rack Processor memory board population guidelines Processor memory boardsPPM Removing a processor ProcessorRemoval and replacement procedures Minimum memory requirements Memory optionsRemoving a Dimm Hot-plug Scsi hard drives Drive replacement precautionsHard drive blanks Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Universal media drives Hot-plug fansRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards PCI-X expansion boards Performance balancingScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane Locating the battery on the system board System batteryRemove the existing battery System board Removal and replacement procedures Cutting the cable tie-wraps AC filter cable assemblyRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Rear panel ConnectorsServer component identification Scsi backplane Scsi backplane board connectorsProcessor and PPM Dimm slotsFront panel LEDsHP ProLiant DL585 Server User Guide on QuickFind diagnostic displayHot-plug Scsi hard drive LEDs Hot-plug Scsi hard drivesHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drive LED combinations Hot-plug SAS or Sata hard drivesHot-plug SAS or Sata hard drive LED combinations Hot-plug fans Hot-plug power suppliesNIC Bbwce Internal diagnostic display System maintenance switch SW3 System board switchesSystem ID switch SW4 System ID Switch SW4 System ID switch SW4ILO/Redundant ROM override switch SW5 Rear unit identification LED switch Non-maskable interrupt switchTroubleshooting If the server does not start Is the system power LED off? Diagnostic stepsIs the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Four-processor memory board configuration Troubleshooting a failed processorTwo-processor memory board configuration Other information resources Server specifications SpecificationsIndex UID LED