Seagate DL585 manual Index

Page 85

Index

A

AC filter cable, 50

AC power supply. See hot-plug power supply

access panel: installing, 18; removing, 18

additional information, 5

ADU. See Array Diagnostics Utility Array Diagnostics Utility (ADU), 54 ASR-2. See Automatic Server

Recovery-2

Automatic Server Recovery-2 (ASR-2), 54

B

battery. See system battery BBWC assembly, 44 BBWCE: LEDs, 67; removing, 44 bus numbering white paper, 38

C

CarePaq, 83 CD-ROM drive, 33

connectors: AC inlets, 56; Integrated Lights-Out Manager, 56; keyboard, 56; mouse, 56; NIC, 56; serial, 56; USB, 56; video, 56

Customer self-repair program, 7

D

data loss caution, 80 diagnostics: accessing, 54;

description, 54; locating, 54 DIMM: population guidelines, 24;

removing, 25

diskette drive, 33

documentation: HP ProLiant DL585 Server User Guide, 60; HP Servers Troubleshooting Guide, 73; HP Servers Troubleshooting Guide, 54; HP Servers Troubleshooting Guide, 74; HP Servers Troubleshooting Guide, 74; HP Servers Troubleshooting Guide, 75; HP Servers Troubleshooting Guide, 77; HP Servers Troubleshooting Guide, 77; HP Servers Troubleshooting Guide, 78; HP Servers Troubleshooting Guide, 79; Integrated Lights-Out User Guide, 54, 68; Service Quick Reference Guide, 5; Smart Array 5i Plug Controller User Guide, 68

drivers, installing, 54 DVD drive, 33

E

electrostatic discharge (ESD), 14 electrostatic-sensitive parts,

precautions, 14

error messages, POST, 79 ESD. See electrostatic discharge events log, 54

expansion boards: installation guidelines, 37; non-hot-plug slot, 38; peak frequency, PCI-X, 37

expansion slots: features, 37; white paper, 38

external health LED, 59

F

fans. See hot-plug fans

features: expansion slots, 37; PCI-X technology, 37

front bezel, 35 front fan cage, 40

front panel thumbscrews, loosening, 16

G

grounding, 14

guidelines: DIMM population, 24; expansion board installation, 37; hot-plug SAS hard drive, 27; hot- plug SATA hard drive, 27; hot-plug SCSI hard drive population, 26; processor memory board population, 20

guides: Factory-Installed Operating System Software Installation Guide, 81; HP Servers Troubleshooting Guide, 83; Integrated Lights-Out User Guide, 54, 68; Service Quick Reference Guide, 5; Smart Array 5i Plus Controller User Guide, 68

H

hard drive blank, 26 help resources, 5

hot-plug fan: configuration, 33; removing, 33

hot-plug hard drive blank. See hard drive blank

hot-plug power supply: blanks, 31; removing, 32

hot-plug SAS hard drive: guidelines, 27; ID numbers, 27; removing, 27 hot-plug SATA hard drive: guidelines, 27; ID numbers, 27; removing, 27

hot-plug SCSI hard drive: removal guidelines, 26; removing, 27

HP authorized reseller, 6

HP SIM. See HP Systems Insight Manager

HP Systems Insight Manager, 6 HP website, 38, 54, 83

I

iLO. See Integrated Lights-Out (iLO) installation problems: factory-installed operating systems, 81; insufficient memory message, 80; operating

system problem, 80; ProLiant Essentials errors, 80; ProLiant Essentials Foundation Pack failure, 80

installation procedures, 18, 22 Integrated Lights-Out (iLO): defined,

54; switch, 68

Integrated Management Log (IML), 6, 54

internal health LED, 59

L

LEDs: BBWCE, 67; external health, 59; internal health, 59; power, 59; UID, 59

M

mechanical components, illustrated, 8 media board, 42

media drive. See universal media drive

memory: eight-DIMM configuration, 24; four-DIMM configuration, 24; insufficient during install, 80; minimum requirements, 24; population guidelines, 24; problem diagnosis, 80

N

NIC: connectors, 56 non-hot-plug PCI-X expansion board,

38

non-maskable interrupt (NMI) switch, 72

non-volatile RAM. See NVRAM normal power-up sequence, 74 NVRAM: clearing, 53, 78; CMOS

problem diagnosis, 80; problem diagnosis, 78; when to clear, 78

O

operating system, installation problems, 80

Index 85

Image 85
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce About this guide Where to go for additional helpAudience assumptions Technician notesTelephone numbers Integrated Management LogCustomer self-repair program Illustrated parts catalogMechanical components exploded view Mechanical components spare parts list‡REQUIREMENT System components exploded view System components spare parts listPPM Sdram ‡REQUIREMENT Safety considerations Removal and replacement proceduresPreparation procedures Electrostatic dischargePowering down the server Extending the server from the rack Locating and removing the Torx T-15 toolRemoval and replacement procedures Installing the access panel Removing the access panelRemoving the server from the rack Processor memory board population guidelines Processor memory boardsPPM Removing a processor ProcessorRemoval and replacement procedures Minimum memory requirements Memory optionsRemoving a Dimm Hard drive blanks Drive replacement precautionsHot-plug Scsi hard drives Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Universal media drives Hot-plug fansRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards PCI-X expansion boards Performance balancingScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane Locating the battery on the system board System batteryRemove the existing battery System board Removal and replacement procedures Cutting the cable tie-wraps AC filter cable assemblyRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Server component identification ConnectorsRear panel Scsi backplane Scsi backplane board connectorsProcessor and PPM Dimm slotsFront panel LEDsHP ProLiant DL585 Server User Guide on QuickFind diagnostic displayHot-plug Scsi hard drive LEDs Hot-plug Scsi hard drivesHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drive LED combinations Hot-plug SAS or Sata hard drivesHot-plug SAS or Sata hard drive LED combinations Hot-plug fans Hot-plug power suppliesNIC Bbwce Internal diagnostic display System maintenance switch SW3 System board switchesSystem ID switch SW4 System ID Switch SW4 System ID switch SW4ILO/Redundant ROM override switch SW5 Rear unit identification LED switch Non-maskable interrupt switchTroubleshooting If the server does not start Is the system power LED off? Diagnostic stepsIs the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Two-processor memory board configuration Troubleshooting a failed processor Four-processor memory board configuration Other information resources Server specifications SpecificationsIndex UID LED