Seagate DL585 manual Nic

Page 66

Table 19 Hot-plug power supply LEDs

(1) Power LED status (green)

(2) Fault LED status (amber)

Description

 

 

 

Blinking

Off

AC power present

 

 

System in standby mode

 

 

 

On

Off

Power supply on and working properly

 

 

 

On

Blinking

Power supply current limit exceeded

 

 

 

NIC

Figure 60 NIC LEDs

Table 20

NIC LEDs

 

 

 

Item

Description

LED color

Status

 

 

 

 

1

Activity LED

Green

On or flashing = Network

 

 

 

 

activity

 

 

 

 

Off = No network activity

 

 

 

 

2

Link LED

Green

On = Linked to the network

 

 

 

 

Off = Not linked to the

 

 

 

 

network

 

 

 

 

 

Server component identification 66

Image 66
Contents HP ProLiant DL585 Server Page Contents NIC Bbwce Audience assumptions Where to go for additional helpAbout this guide Technician notesIntegrated Management Log Telephone numbersIllustrated parts catalog Customer self-repair programMechanical components spare parts list Mechanical components exploded view‡REQUIREMENT System components spare parts list System components exploded viewPPM Sdram ‡REQUIREMENT Preparation procedures Removal and replacement proceduresSafety considerations Electrostatic dischargePowering down the server Locating and removing the Torx T-15 tool Extending the server from the rackRemoval and replacement procedures Removing the access panel Installing the access panelRemoving the server from the rack Processor memory boards Processor memory board population guidelinesPPM Processor Removing a processorRemoval and replacement procedures Memory options Minimum memory requirementsRemoving a Dimm Drive replacement precautions Hard drive blanksHot-plug Scsi hard drives Hot-plug SAS or Sata hard drives SAS or Sata hard drive cage Power transfer board Removal and replacement procedures Power supply blank Hot-plug power supplies Hot-plug fans Universal media drivesRemoving a drive from bay Front bezel Power button/LED assembly Expansion boards Performance balancing PCI-X expansion boardsScsi cables Front fan cage Pass-through board QuickFind diagnostic display board and lightpipe Rear fan cage Bbwc assembly Scsi backplane System battery Locating the battery on the system boardRemove the existing battery System board Removal and replacement procedures AC filter cable assembly Cutting the cable tie-wrapsRemoval and replacement procedures Removal and replacement procedures Re-entering the server serial number Diagnostic tools Diagnostic toolsPost Connectors Server component identificationRear panel Scsi backplane board connectors Scsi backplaneDimm slots Processor and PPMLEDs Front panelQuickFind diagnostic display HP ProLiant DL585 Server User Guide onHot-plug Scsi hard drives Hot-plug Scsi hard drive LEDsHot-plug Scsi hard drive LED combinations Hot-plug SAS or Sata hard drives Hot-plug SAS or Sata hard drive LED combinationsHot-plug SAS or Sata hard drive LED combinations Hot-plug power supplies Hot-plug fansNIC Bbwce Internal diagnostic display System board switches System maintenance switch SW3System ID switch SW4 System ID switch SW4 System ID Switch SW4ILO/Redundant ROM override switch SW5 Non-maskable interrupt switch Rear unit identification LED switchTroubleshooting If the server does not start Diagnostic steps Is the system power LED off?Is the internal health LED green? Servers Troubleshooting Guide Is the monitor displaying information? Error message Problems after initial boot Provided in the Factory-Installed Troubleshooting a failed processor Two-processor memory board configurationFour-processor memory board configuration Other information resources Specifications Server specificationsIndex UID LED