Overview of DFE-Platinum Module Shutdown Procedure

Recommended Shutdown Procedure

Caution: Do not remove a DFE module from an operating chassis system before reading the following information and instructions.

Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes instrucciones y la información suministrada.

Before pulling a DFE‐Platinum module out of a chassis,

press or tap on its OFFLINE/RESET switch for less than 1 second.

Its CPU LED changes from solid green to blinking between green and amber, indicating that the module is shutting down. At the end of the shutdown routine, the CPU LED changes to a 67%/ 33% sequence of amber/off, respectively, indicating the module is in a halt state. In this time it is safe to restart or remove the module from the chassis.

When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 seconds from the time the CPU starts alternately flashing amber/off until the device automatically restarts.

Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the CPU LED is alternately flashing amber/off. Otherwise, system operation will be interrupted.

Last Resort Shutdown Procedure

Caution: This method of shutting down a DFE module is not recommended except as a last resort, because all processes currently running on the module will be interrupted resulting in loss of frames.

Precaución: No se recomienda utilizar este método para apagar los módulos DFE. Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del módulo en funcionamiento, lo que podría resultar pérdidas de frames.

To reset a DFE‐Platinum module without it performing an orderly shutdown routine,

press and hold the OFFLINE/RESET switch for approximately 6 seconds.

Pulling any DFE‐Platinum module out of the chassis before it has been shut down is not recommended. The only safe time to pull a module out of the chassis is after the completion of a shutdown and the management LED is alternately flashing amber/off.

4-6 Troubleshooting

Image 46
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Enterasys NETWORKS, INC. Firmware License Agreement Vii Viii Contents Index Appendix a SpecificationsTables Who Should Use This Guide About This GuideImportant Notice How to Use This Guide Related DocumentsConventions Used in This Guide Getting HelpGetting Help Introduction Overview of DFE Series CapabilitiesDFE-Platinum Module 2G4082-25DFE Network Expansion Module NEM Option Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ConnectivitySecure Networks Policy Support Lanview Diagnostic LEDsStandards Compatibility Lanview Diagnostic LEDs Introduction Network Requirements Link Aggregation1000BASE-T Network 10BASE-T Network100BASE-TX Network 1000BASE-SX/LX/ELX NetworkInstallation Installing Module into Matrix E7 or N7 Chassis Installing Optional Network Expansion ModulesUnpacking the DFE-Platinum Module Installation PreparationCard guides Installing Module into Matrix N1, N3, or N5 Chassis Connecting to the Network Connecting UTP CablesConnecting a Twisted Pair Segment to the DFE-Platinum Module RX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 What Is Needed Connecting to COM Port for Local ManagementConnecting to an IBM PC or Compatible Device Connecting to a VT Series Terminal Connecting an IBM PC or CompatibleConnecting to a Modem Connecting a VT Series TerminalAdapter Wiring and Signal Assignments DB9Modem Port Adapter Wiring and Signal Diagram Completing the Installation of a New System First-Time Log-In Using a Console Port ConnectionLogging in with an Administratively-Configured User Account 11 Matrix DFE Startup Screen Example N7 ChassisAbout the Management Mgmt LED TroubleshootingUsing Lanview Viewing the Receive and Transmit ActivityLED Alternating 67% on, 33% off Troubleshooting Checklist Series Configuration Guide for proper setupOverview of DFE-Platinum Module Shutdown Procedure Recommended Shutdown Procedure Specifications DFE-Platinum Module SpecificationsCOM Port Pinout Assignments Regulatory ComplianceSetting the Mode Switches Mode Switch Bank Settings Optional InstallationsRequired Tools Memory Locations and Replacement Procedures Figure B-1 Mode Switch Location on 2G4082-25Location of Memory Modules Flash Dimm Replacement ProcedureRemoving the Dimm from 2G4082-25 Figure B-3 NEM Removal and Dimm Connector Location Installing the Dimm DimmInstalling the Dram Simm Dram Simm Replacement ProcedureRemoving the Dram Simm Figure B-7 Installing the Dram Simm Page Index NumericsIndex-2