  | PRELIMINARY | CY7C2561KV18, CY7C2576KV18  | |
  | 
  | CY7C2563KV18, CY7C2565KV18 | ||
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
Electrical Characteristics (continued)
DC Electrical Characteristics
Over the Operating Range [16]
Parameter | Description  | Test Conditions  | 
  | Min  | Typ  | Max  | Unit  | |
ISB1  | Automatic Power down  | Max VDD,  | 550 MHz  | (x8)  | 
  | 
  | 380  | mA  | 
  | Current  | Both Ports Deselected,  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | (x9)  | 
  | 
  | 380  | 
  | ||
  | 
  | VIN ≥ VIH or VIN ≤ VIL  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | (x18)  | 
  | 
  | 380  | 
  | |
  | 
  | f = fMAX = 1/tCYC,  | 
  | 
  | 
  | 
  | ||
  | 
  | Inputs Static  | 
  | (x36) | 
  | 
  | 380  | 
  | 
  | 
  | 
  | 500 MHz  | (x8)  | 
  | 
  | 360  | mA  | 
  | 
  | 
  | 
  | (x9)  | 
  | 
  | 360  | 
  | 
  | 
  | 
  | 
  | (x18)  | 
  | 
  | 360  | 
  | 
  | 
  | 
  | 
  | (x36)  | 
  | 
  | 360  | 
  | 
  | 
  | 
  | 450 MHz  | (x8)  | 
  | 
  | 340  | mA  | 
  | 
  | 
  | 
  | (x9)  | 
  | 
  | 340  | 
  | 
  | 
  | 
  | 
  | (x18)  | 
  | 
  | 340  | 
  | 
  | 
  | 
  | 
  | (x36)  | 
  | 
  | 340  | 
  | 
  | 
  | 
  | 400 MHz  | (x8)  | 
  | 
  | 320  | mA  | 
  | 
  | 
  | 
  | (x9)  | 
  | 
  | 320  | 
  | 
  | 
  | 
  | 
  | (x18)  | 
  | 
  | 320  | 
  | 
  | 
  | 
  | 
  | (x36)  | 
  | 
  | 320  | 
  | 
AC Electrical Characteristics
Over the Operating Range [15]
Parameter | Description  | Test Conditions  | Min  | Typ  | Max  | Unit  | 
VIH  | Input HIGH Voltage  | 
  | VREF + 0.2  | –  | VDDQ + 0.24  | V  | 
VIL  | Input LOW Voltage  | 
  | –  | VREF – 0.2  | V  | 
Capacitance
Tested initially and after any design or process change that may affect these parameters.
Parameter | Description | Test Conditions | Max | Unit | 
CIN  | Input Capacitance  | TA = 25°C, f = 1 MHz, VDD = 1.8V, VDDQ = 1.5V  | 2  | pF  | 
CO  | Output Capacitance  | 
  | 3  | pF  | 
Thermal Resistance
Tested initially and after any design or process change that may affect these parameters.
Parameter | Description | Test Conditions | 
  | 165 FBGA | Unit | 
  | Package  | ||||
  | 
  | 
  | 
  | 
  | |
ΘJA  | Thermal Resistance  | Test conditions follow standard test methods  | With Still Air  | 13.7  | °C/W  | 
  | (Junction to Ambient)  | and procedures for measuring thermal  | (0m/s)  | 
  | 
  | 
  | 
  | impedance, in accordance with EIA/JESD51.  | 
  | 
  | 
  | 
  | 
  | With Air flow  | 12.56  | 
  | |
  | 
  | 
  | 
  | ||
  | 
  | 
  | (1m/s)  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
ΘJC  | Thermal Resistance  | 
  | 
  | 3.73  | °C/W  | 
  | (Junction to Case)  | 
  | 
  | 
  | 
  | 
Document Number:   | Page 22 of 29  | 
[+] Feedback