D. CHANGE BAUD RATE ?

If you want to change the baud rate of serial communication, choose YES here and if not, choose NO and go to next items.

If you choose YES, baud rate choice such as Ò1200 bps ?Ó are shown continuously. If the baud rate is right one, choose YES and if not, choose NO.

When YES is chosen, printer prints next menu items.

The choice of baud rate are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps. The default setting is 9600 bps.

E. CHANGE AUTO POWER OFF TIME ?

If you want to change the auto power off time setting, choose YES here and if not, choose NO and go to next item.

If you choose YES, choice of time length such as Ò5 min ?Ó are shown continuously. If the time is right one, choose YES and if not, choose NO. When YES is chosen, printer prints next menu items.

The choice of time length is 5, 10, 15, 20, 25, 30, 45, 60 min.

If you want to set to the time not in this choice, you can set the time by command. The default setting is 10 min.

F. CHANGE PRINT DENSITY ?

If you want to change the print density, choose YES here and if not, choose NO and go to next item.

If you choose YES, density choice such as Ò70 % ?Ó are shown continuously. If the density is right one, choose YES and if not, choose NO.

When YES is chosen, printer prints next menu items. Choice of density is 70%, 80%, 90%, 100%, 120%, and 150%. Default density setting is 100%.

G. CHANGE IrDA MAX SPEED ?

If you want to change Max speed of IrDA to 57600 bps, choose YES here and if not, choose No and go to next item.

If you choose YES, another question ÒLIMIT SPEED TO 57600 bps ?Ó shows up. Then choose YES or NO. When you choose either one, printer prints next menu items. Default setting is NO.

If the communication via IrDA is not stable, please try to set YES.

H. SAVE SETTINGS ?

During the menu setting, if YES is chosen somewhere, this items is printed. (If only NO is chosen, printer does not print this item and turn the power off.)

If you want to save the changed setting, choose YES here and if not, choose NO.

If YES is not chosen, the changed setting will not be lost.

If YES is chosen printer prints ÒHARDWARE SETTING SAVED !Ó then print new setting then turn the power off.

If NO is chosen, printer prints ÒHARDWARE SETTING NOT SAVED !Ó then turn the power off.

Caution

Setting values exist in 2 areas. One is in RAM and the other one is in flash. Setup menu changes both settings. Settings in RAM are valid for the actual usage and it can be printed by self test. The setting values printed during menu setup are from flash. (There is a command to save the setting in RAM to flash. If the setting in RAM is destroyed by some reason, the setting in flash is loaded to RAM.) Setting in RAM can be changed by a command. If you do not save the changed value to flash, difference exists between RAM and flash.

Ñ 68 Ñ

Image 70
Contents Command Reference Revision CMP-10 Command SET Code Command FunctionGS L GS HGS W Command Details Xxxx ALLBEL Sample Program Print Results0AH ESC RS Default Sample Program ESC SP nESC ! n Default See AlsoBit Function Value END ESC $ n1 n2 ESC % n Initialize command ESC & m n1 n2 d kESC * m n1 n2 d k Hex Mode Vertical Direction Horizontal Direction DotsMax. Dots IMG1 Page ESC n ESC +Hex Type ESC ESC 3 n ESC = n Bit Equipment Value21 Ñ ESC ? n Hex TrackESC @ ESC D n k NUL See Also Sample Program Print ResultsESC E n ESC G n ESC R n ESC J nHex Character Set Hex Speed bps ESC S nESC T Model CMP-10 VerESC V n Hex ConditionESC Y n ESC Z ByteUpdate via firmware interface Not in use Reserved, always 33 Ñ ESC \ n1 n2 ESC ` ESC a n Hex PositionESC c5 n ESC d n ESC ESC x n B B B Memory Switch OFF GS n mGS * n1 n2 d n1 n2 D1 ...... Dn See Also Sample ProgramGS / m Hex Name Dot Density Vertical Direction Horizontal Direction1DH3AH GS H n Hex Printing PositionGS L nL nH GS W n NL = 40 Hex, nH = 2 Hex Hex Mode GS n1 n2 n3GS a n Bit Status Item Addressed by ABSNot in use Thermal head is overheated Disabled for ASB may also have changed GS f n Hex Font1DH68Hn Bar code system Range of k Range of d GS k m d1 ..... dk NUL GS k m n d1 ...... dnBar code system Range of n Range of d For For Standard ModeDescription of Bar Codes JAN-8EAN Hex Code set a Code set B Code set CJAN-8 Type Print Sample Outline of Symbol Max. ColumnDescriptionof Bar Codes CODE93 CODE128GS w nL nH AT*PAIRINFO=0 AT command Function Factory defaultAT*PAIRINFO=1 Bluetooth Init Commands ExampleBlack Mark Function ESC l nDistance from PE sensor and print head is approx .5 mm Character Codes Table Setup menu function After Ver2.20 If YES is not chosen, the changed setting will not be lost Change IrDA MAX Speed ?Memory switches OFF0 ON1 Memory switch 8 =Change Print Density ? Programming Considerations Pin No Signal Direction Function Pin No. of Cable Serial InterfaceExplanation of Input/Output Signals 14, 15 pin Communicate mode settingElectrical Characteristics RS-232C CircuitInfrared Communication Specifications IrComm 3 Wire raw IrLPTMechanical Specification McbfPower Related Specifications BatteryEMI Standard AC AdaptorUL, C-UL, PSE 10AD-JU