6.3Explanation of Input/Output Signals
(1)RXD
This is signal, receiving data from the host. On occurrence of framing error, overrun error, or parity error, the data is printed as Ò?Ó.
(2)TXD
This signal is for data flow control by
(3)Vcc
This is a power supply (+5 V). The signal is not use in the standard serial cable!
(4)GND
This is a GND on the circuit.
(5)Auto
The printer can be turned on by using RTS signal from the host
CAUTION: Ensure that the RTS signal is deactivated when your application software not using the printer as auto
14, 15 pin (Communicate mode setting)
Using dedicated cable makes these pin
If these pins are
6.4 Error Detection
Framing and overrun are detected. On detection of any error, the data are stored in the buffer as Ò?Ó.
(1)Framing Error
With ÒspaceÓ state having been detected on detection of a stop bit, error takes place. The data are stored in the buffer as Ò?Ó.
(2)Overrun Error
On detection of an overrun error, the data are stored in the buffer as Ò?Ó.
6.5Buffering
This printer incorporates 64K byte buffer. This allows most print jobs to by fully buffered so that the host can continue quickly.
Ñ 73 Ñ