Brick Motion Controller Hardware Reference Manual
J4 Limit Inputs (1-4 Axis)
The Brick Motion Controller limit and flag circuits give the flexibility to wire in standard 12V to 24V limits and flags or wire in 5V level limits and flags on a channel basis. The default is set for the standard 12V to 24V inputs, but if the resistor pack is added to the circuit, the card can read 5V inputs.
J4 Limit Inputs | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | ||
(Female | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Connector) | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 |
| 14 | |
|
|
| |||||||||||||
Pin # | Symbol | Function | Description |
|
|
|
|
|
|
|
| ||||
1 | USER1 | Input | User Flag 1 |
|
|
|
|
|
|
|
| ||||
2 | MLIM1 | Input | Negative Limit 1 |
|
|
|
|
|
|
| |||||
3 | FL_RT1 | Input | Flag Return 1 |
|
|
|
|
|
|
|
| ||||
4 | USER2 | Input | User Flag 2 |
|
|
|
|
|
|
|
| ||||
5 | MLIM2 | Input | Negative Limit 2 |
|
|
|
|
|
|
| |||||
6 | FL_RT2 | Input | Flag Return 2 |
|
|
|
|
|
|
|
| ||||
7 | USER3 | Input | User Flag 3 |
|
|
|
|
|
|
|
| ||||
8 | MLIM3 | Input | Negative Limit 3 |
|
|
|
|
|
|
| |||||
9 | FL_RT3 | Input | Flag Return 3 |
|
|
|
|
|
|
|
| ||||
10 | USER4 | Input | User Flag 4 |
|
|
|
|
|
|
|
| ||||
11 | MLIM4 | Input | Negative Limit 4 |
|
|
|
|
|
|
| |||||
12 | FL_RT4 | Input | Flag Return |
|
|
|
|
|
|
|
| ||||
13 | GND |
|
|
|
|
| Common |
|
|
|
|
|
| ||
14 | PLIM1 | Input | Positive Limit 1 |
|
|
|
|
|
|
| |||||
15 | HOME1 | Input | Home Flag 1 |
|
|
|
|
|
|
|
| ||||
16 | BEQU1 | Output | Compare Output, EQU 1, signal is TTL (5V) level |
|
| ||||||||||
17 | PLIM2 | Input | Positive Limit 2 |
|
|
|
|
|
|
| |||||
18 | HOME2 | Input | Home Flag 2 |
|
|
|
|
|
|
|
| ||||
19 | BEQU2 | Output | Compare Output, EQU 2, signal is TTL (5V) level |
|
| ||||||||||
20 | PLIM3 | Input | Positive Limit 3 |
|
|
|
|
|
|
| |||||
21 | HOME3 | Input | Home Flag 3 |
|
|
|
|
|
|
|
| ||||
22 | BEQU3 | Output | Compare Output, EQU 3, signal is TTL (5V) level |
|
| ||||||||||
23 | PLIM4 | Input | Positive Limit 4 |
|
|
|
|
|
|
| |||||
24 | HOME4 | Input | Home Flag 4 |
|
|
|
|
|
|
|
| ||||
25 | BEQU4 | Output | Compare Output, EQU 4, signal is TTL (5V) level |
|
|
If RP39 (limits 1), RP43 (limits 2), RP47 (limits 3) and RP51 (limits 4) are installed to the unit, the voltage level of the flags can be lowered to 5V. User needs to specify these when ordering the unit.
RP39, RP43, RP47 and RP51 for 5V flags: 1Kohm Sip,
RP39, RP43, RP47 and RP51 for
12 | System Wiring |