Limitorque MX DeviceNet Field Unit  FCD LMENIM2328-00 – 11/05

5.2EDS File

The DeviceNet Limitorque Interface can be configured using Rockwell Automation RSNetWorx for DeviceNet and an EDS-File. Table 5.1 shows a list of all supported parameters.

Table 5.1 Parameter List

Parameter

Access

Path to Object

No.

 

 

1-23

Read/Write resp. Read Only

Channel Interface Object, Instance Attributes 1-23

24-78

Read/Write resp. Read Only

Transducer Block Object, Instance Attributes 1-55

79

Read/Write

DeviceNet Object, Instance Attribute ‘MAC ID’

80

Read/Write

DeviceNet Object, Instance Attribute ‘Baud Rate’

81

Read

DeviceNet Object, Instance Attribute ‘MAC ID

 

 

Switch Changed’

83

Read

DeviceNet Object, Instance Attribute ‘MAC ID

 

 

Switch Value’

85

Read/Write

DeviceNet Object, Instance Attribute ‘Autobaud’

86

Read/Write

Connection Object, Poll Instance Attribute ‘Polled

 

 

I/O Input’

87

Read/Write

Connection Object, Poll Instance Attribute ‘Polled

 

 

I/O Output’

88

Read/Write

Connection Object, Bit-Strobe Instance Attribute

 

 

‘Bit-Strobe I/O Input’

89

Read/Write

Connection Object, COS/Cyclic Instance Attribute

 

 

‘COS/Cyclic I/O Input’

6 Associated Documents

Quick Start-Up Instructions (Limitorque MX Actuators): Limitorque Bulletin LMAIM1310/2310

MX Installation and Operation Manual: Limitorque Bulletin LMAIM1306/2306

Protection, Control and Monitoring Features of MX Electric Actuators: Limitorque Bulletin LMABR1300/2300

MX Maintenance and Spare Parts Manual: Limitorque Bulletin LMAIM1314/2314 ODVA Planning and Installation Manual available from ODVA.

7 Troubleshooting

Refer to Section 10, Wiring Diagram.

1.With power off and network disconnected, verify continuity between A1, A2 and A1*, A2*.

2.With power applied and network disconnected, verify 0.2 to 0.45 VDC between A1, A1* and A2, A2*.

3.Confirm that a jumper cable is installed between the grounding lug and terminal 30.

Verify proper setup for MX DeviceNet.

4. MPC (modulating position control) must be OFF.

5.ESD must be configured for desired function and properly wired.

6.OPEN INHIBIT must be configured for desired function and properly wired.

Image 38
Contents User Instructions Disclaimer Contents EDS File Declaration of Conformity to the DeviceNet Specification Declaration of DeviceNet Conformance Odva CertificationAbbreviations Introduction Purpose How to Use this ManualUser Safety User Knowledge DeviceNet System Capabilities and FeaturesGeneral Specifications Network specifications MX Field Unit SpecificationsHardware System ComponentsIntroduction Limitorque MXDeviceNet Field Unit DeviceNet Field UnitNetwork Cable Belden Cable SpecificationsHardware interface Site Preparation Installation and ConfigurationSite and Network Cable Preparation Network Cable PreparationCable Preparation Dnfu Installation Verification Installation VerificationNetwork Cabling Installation Verification Object Model Diagram Assembly ObjectsOutput Assembly Instances Output Assembly InstanceClass Instance Attribute Data Name Type Input Assembly Instance 10 Input Assembly Instance 11 Input Assembly Instance14 Possible values of DIPositionChan DIPositionandBusModeChanDIPositionChan 16 Possible values of DIActuatorFaults1Chan DIActuatorFaults2ChanDIActuatorAlarmsChan 18 Possible values of DIActuatorFaults2ChanDIReadDiscOutputChan 20 Possible values of DIActuatorAlarmsChanDIDiscUserInputChan DOPositionChanDORelayChan DIActuatorFaults3ChanDIAlarms2Chan CtrlStatusChanName Data Description Bit 7 Bit Reserved Low BatteryChannel Interface Object Type AttributeTransducer Block Object Name Data Type Description Semantics of ValueName Data Type Description Semantics of Value 33 Transducer Attribute Scaled values attribute Bit 7Bit 15 Bit 10 Identity Object Instance Attributes35 Identity Object Instance Attributes Description Semantics of Value AttributeEvent Source Description Behavior36 Behavior Name Data Description Semantics of Value Type Attribute DeviceNet Object Instance Attributes37 DeviceNet Object Instance Attributes Instance ID Channel Interface Object Source Discrete Input Point Object Class ID 8 08hex38 Discrete Input Point Object Analog Output Point Object Class ID 11 0Bhex Discrete Output Point Object Class ID 9 09hexAnalog Input Point Object Class ID 10 0Ahex 39 Discrete Output Point ObjectBaud Rate Network ManagementMAC ID Offline Connection Set Device Heartbeat MessageChecking Connections Configuration ConfirmationDevice Shutdown Message 43 Format of the Device Shutdown MessageView Settings View DeviceNet StatusChecking the Normal Display Associated Documents TroubleshootingAccess Path to Object EDS FileWorkmanship How to Order Parts Regulatory InformationWiring Diagram Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 11/05 Flowserve.com Flowserve.com