■All Reset
When the all reset mode is activated, all of the following set- tings will be reset to the factory default.
•Administrator password
•PS·Data communication setting
•LCD brightness, contrast, alarm buzzer, and button buzzer settings
•Button functions and joystick button functions (F1 to F8, A, B, and top buttons)
•Controller functions
(Time & Date Type)
(Auto Login)
(Operator Setup)
(Function Level)
(Camera Level)
(Cam Posi Map)
(LCD Title)
Note: Calibration settings of panning, tilting, and zooming will be maintained even after all reset.
●Operation
1.Turn off the power.
Note: If you set the MODE Switch #1 to #4 to ON, you can skip entering the administrator password in Step 3.
2.Turn on the power while holding down the buttons 2, 4, and 6.
“Admin Password” will appear on the LCD to enter the password.
All Reset
Admin Password _____
3.Enter the administrator password.
The password entered will be displayed as “∗” marks.
All Reset
Admin Password ∗ ∗ ∗ ∗ ∗
Notes:
•The factory default is “650”.
•To delete a character, press the CLEAR button.
•If you have entered a wrong password, the LCD display will return to Step 2.
4.Press the CAM (SET) button.
If the password entered is correct, all the settings will be reset to the factory default.
All Reset
5.Check “End” on the LCD.
Check “End” has appeared on the LCD to inform you of the initialization end.
All Reset
End
6. Turn off the power.
■PS·Data Communication Setting
This setting is required to establish a connection between the system units and system controller.
List of PS·Data communication settings
Setting Item Available setting parameter(s)
Baud Rate | 4800 / 9600 / 19200 bps |
Data Bit | 8 bit (Fixed) |
Parity Bit | None / Odd / Even |
Stop Bit | 1 / 2 bit |
Wait Time | OFF / 100 msec / 200 msec / |
| 400 msec / 1000 msec |
|
|
Group Adr | A to Z |
Xon/Xoff | Not Use (Fixed) |
Note: Factory defaults are underlined.
●Operation
1.Turn off the power.
2.Turn on the power while holding down the button 6 and MON (ESC) button.
“Admin Password” will appear on the LCD to enter the password.
PS • Data Com. Setup
Admin Password _____
20