■Database Copy
You can copy the database from the source system con- troller (CONTROLLER NO. switch is set to 1.) to destination system controllers (CONTROLLER NO. switch is set to 2 to 8.). When using two or more system controllers in the sys- tem, you can copy the following settings.
•Administrator password
•Button functions and joystick button functions (F1 to F8, A, B, and top buttons)
•Controller functions
(Time & Date Type)
(Auto Login)
(Operator Setup)
(Function Level)
(Camera Level)
(Cam Posi Map)
(LCD Title)
Notes:
•Database copy to two or more system controllers is available at a time.
•To activate this mode, you need to perform the PS·Data communication settings. (Refer to p. 20 PS·Data Communication Setting.)
•This function is available only among
●Operation
1.Turn off the power of source and destination system controllers.
2.Disconnect the system units from source and destination system controllers.
3.Connect system controllers with modular cables.
4.Set the MODE switches of source and destination system controllers to “PS·Data” mode.
5.Set the CONTROLLER NO. switch of source system controller to “1”, and that of destination system controllers to “2” to “8”.
(Refer to p. 18 CONTROLLER NO. Switch Setting.) Note: Set a unique number for each system controller
to avoid conflict.
6.Turn on the power of destination system controller. Login is not required.
7.Turn on the power of source system controller while holding down the button 2 and MON (ESC) buttons. “Admin Password” will appear on the LCD to enter the password.
Data Base Copy Mode
Admin Password _____
8.Enter the administrator password.
The password entered will be displayed as “∗” marks.
Data Base Copy Mode
Admin Password ∗ ∗ ∗ ∗ ∗
Note: The factory default is “650”.
9.Press the CAM (SET) button.
If the password entered is correct, the LCD display of source system controller becomes as follows.
Data Base Tx Mode
“Enter SET Button”
The LCD display of destination system controller(s) become(s) as follows.
Data Base Rx Mode
10.Press the CAM (SET) button of the source system controller.
The database copy will be started, and the LCD display of source system controller becomes as follows.
Data Base Tx Mode
Completed 60%
The LCD display of destination system controller(s) become(s) as follows.
Data Base Rx Mode
Completed 60%
11.When the copy has been completed, the check sum (SUM=nnnn) appears on the LCD of each system controller.
When the copy has been successfully completed, the check sum is identical to each other.
The LCD display of source system controller becomes as follows.
Data Base Tx Mode
Completed Sum=1733