SYSTEM UNIT CONTROL
The following are the procedures to control system units (including recorders).
■Multiscreen Display
The following procedure is available when a selected sys- tem unit (for example, a hard disk recorder) has the multi- screen display function.
1.Select a system unit and monitor. (Refer to p. 31 System Unit Selection and p. 32 Monitor Selection.)
2.Do either of the following.
•Press the MULTI SCREEN button.
•Press the desired numeric buttons (refer to the dia- gram), then press the MULTI SCREEN button.
Images will be displayed in the specified multiscreen segment pattern on the monitor. Every pressing the MULTI SCREEN button can change the multiscreen segment pattern.
Numeric buttons Multiscreen display pattern
0 | 4 segments |
1 | 7 segments |
2 | 9 segments |
3 | 10 segments |
4 | 13 segments |
5 | 16 segments |
Note: Available multiscreen segment patterns differ depending on system units. Refer to the operating instructions of system units.
■Electronic Zooming
The following procedure is available when a selected sys- tem unit has the electronic zooming function.
1.Select a system unit, monitor, and camera. (Refer to p. 31 System Unit Selection, p. 32 Monitor Selection, and p. 32 Camera Selection)
2.Press the
■Tour Sequence/Group Sequence
Sequence monitoring is the function to switch camera images automatically, according to the order registered in the system unit. The following procedure is available when a selected system unit has the tour or group sequence monitoring function.
Note: Before performing the procedure, the sequence setup of system unit is required.
1.Select a system unit and monitor. (Refer to p. 31 System Unit Selection and p. 32 Monitor Selection.)
2.Enter a desired sequence number.
3.To activate a tour sequence, press the TOUR SEQ/GROUP SEQ button.
To activate a group sequence, press the TOUR SEQ/GROUP SEQ button while holding down the SHIFT button. The sequence will be activated, and “Seq” will appear on the monitor, in place of the camera number.
Mon02 | Seq |
| HD316 |
F1 | F2 | F3 | F4 |
Notes:
•If you have skipped entering the sequence number in Step 2, Tour or Group Sequence 1 will be activat- ed.
•If the selected recorder supports sequence paus- ing, you can pause the sequence by pressing the SEQ PAUSE/SEQ STOP button. During the sequence pause,
3.To quit the sequence monitoring, press the SEQ PAUSE/SEQ STOP while holding down the SHIFT but- ton. The monitor display will return to the spot mode.
Note: If the selected system unit does not support sequence stop, stop the sequence by selecting a camera or activating the multiscreen display. (Refer to p. 32 Camera Selection or Multiscreen Display in this page.)
3.To move the zoomed area, move the 3D joystick to desired directions. (Refer to the operating instructions of system unit.)
Note: Available zooming rates differ depending on sys- tem units. (Refer to the operating instructions of sys- tem units for details.)
■On-screen Display (OSD) Control
You can toggle the OSD information (display parameters such as camera title, monitor number, and recorder num- ber) on the active monitor screen.
33