Panasonic WV-CU650 operating instructions Camera Level Setting

Page 64

4.Select a desired function by performing one of the fol- lowing.

Rotate the JogDial clockwise or counterclockwise.

Press the + or – button.

Enter the function number with the numeric buttons. The function setting will appear on the LCD.

Function Table2 405 08 IRIS OPEN/CLOSE=E

The following diagram describes the function settings changeable and their factory defaults.

Function

Table 2

Table 3

01 MENU

D

D

02 F1 – F4

E

E

03 F5 – F8

E

E

04 A B

E

E

05 TOP SW

E

E

06 JOYSTICK

E

E

07 FOCUS NEAR/FAR E

E

08 IRIS OPEN/CLOSE E

D

09 CAM/SET

E

E

10 MON/ESC

E

E

11 UNIT

E

E

12 RECORDER

E

E

13 CAM POSI

E

E

14 PRESET

E

E

15 PGM PRESET

D

D

16 HISTORY

E

E

17 –/+

E

E

18 JOG DIAL

E

E

19 SHUTTLE RING E

E

20 SHUTTLE HOLD E

E

21 PLAY/PAUSE

E

E

22 STOP

E

E

23 REC

E

D

24 ALM SUSPEND

E

D

25 ALM RESET

E

E

26 OSD

E

E

27 ALM RECALL

E

E

28 SEQ PAUSE

E

E

29 SEQUENCE

E

E

30 MULTI SCREEN E

E

31 EL-ZOOM

E

E

32 AUX1 ON/OFF E

E

33 AUX2 ON/OFF E

E

34 DEF ON/OFF

E

E

35 WIPER ON

E

E

36 SYS FUNC

D

D

37 CAM FUNC

D

D

38 GO TO LAST

E

E

39 MARK

E

E

40 SEARCH

E

E

41 T&D SEARCH

E

E

E=Enabled, D=Disabled

5.Rotate the shuttle ring clockwise or move the 3D joy- stick to the right. The cursor will jump to the next item.

Function Table2 405 08 IRIS OPEN/CLOSE=E

Note: To return to Step 4, rotate the shuttle ring coun- terclockwise or move the 3D joystick to the left.

6. Select E or D by performing either of the following.

Function Table2 405 08 IRIS OPEN/CLOSE=D

Note: To change the settings of other functions, repeat Step 4 to 6.

7.Press the ENTER or CAM (SET) button. “Set OK?” will appear on the LCD.

Function Table2 405

Set OK?

Note: To cancel the setting, press the EXIT or MON (ESC) button. The LCD display will return to Step 6.

8. Press the ENTER or CAM (SET) button again.

Function Table2 405

Memory

The function levels will be set for the selected table. “Memory” will appear on the LCD for a few seconds, and the LCD display will return to Step 1.

Camera Level Setting

You can change the camera levels for each operator. The camera levels range between Table No. 1 (highest level) and 3 (Lowest level).

Notes:

Table No. 1 is fixed to E (Enabled) for all cameras.

As the factory default, Table No. 2 and 3 are set to E for all cameras.

1.Display “Camera Level” sub menu. (Refer to Step 1 to 4 of p. 51 To Recall Menu Functions.)

Camera

Level

406

Table

No.

=1

2.Select a desired table (= camera level) by performing one of the following.

Rotate the JogDial clockwise or counterclockwise.

Press the + or – button.

Enter the function number with the numeric buttons.

Camera

Level

406

Table

No.

=3

3.Press the CAM (SET) button.

The setting menu for the selected table will appear on the LCD.

64

• Rotate the JogDial clockwise or counterclockwise.

• Press the + or – button.

Image 64
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefacePrecautions Limitation of LiabilityDo not drop metallic parts through slots Do not attempt to disassemble the applianceDocument Convention Notification about System UnitsMain Unit Front View0Alarm recall button ALM Recall Camera function/System function button1On-screen display button OSD 2Monitor lock/Logout button MON LOCK/LOGOUT#3Preset/Program preset button PRESET/PGM #9Adjustment button Adjust@8Shuttle hold button Shuttle Hold @9History button HistoryRear View 3D Joystick Unit LCD Display Descriptions Default Status LCD Display After LoginMon02 Cam016 HD316 Sub Menu Menu Functions Main Menu Menu FunctionsBlinking Controller No.1 No Exist Error Messages Displayed on the LCDInvalid Mon02 Cam016 HD316 BusyInstallations and Connections Basic System ConnectionsAdjustment of 3D Joystick Connection with the 3D Joystick UnitSetup Procedures Hardware Setup ProceduresMode Switch Setting Controller NO. Switch SettingSetup Procedures Firmware Administrator Password EntrySetting Modes Setting Mode DescriptionPS·Data Communication Setting All ResetOperation Baud Rate Setting Stop Bit Setting Parity Bit SettingWait Time Setting Group Address Setting for System Controller Group Address Setting for System UnitsTo Change the Administrator Password Database Copy PS·Data Operator Password Check Data Base Rx Mode Completed Sum=1733PSD Password Check Admin Password PSD Password Check Admin Password ∗ ∗ ∗ ∗ ∗Power-off Power-onBefore Operation LCD/BUZZER Adjustment Buzzer AlarmBasic Operation Flow LCD BrightOperation Start Login If You Have Forgotten the Login Password Operation Start Auto LoginPS Data Mode Auto Login Logout PS·Data Mode No UserSystem Unit Selection Unit SelectionRecorder Selection Monitor Selection Camera SelectionSystem Unit Control Multiscreen DisplayElectronic Zooming Tour Sequence/Group SequenceSystem Function Control How to Display Search Lists Recorder ControlManual Recording Search PlaybackSearch Mode HD300 List Text Copy Nr-A Cp-A Cpy1 Cpy2 Example of searching filter display and settingsOperation WJ-HD300 Series Available buttons and functionsSearch Mode HD500 Edit Group Alm Copy Search Mode HD500 DriveOperation WJ-HD500 Series LCD displaySearch Mode HD200 Time & Date Search PlaybackOperation WJ-HD200 Series Mmm/DD/YYYY Hhmm Mar/16/2004 0132 PMOther Available Functions Camera Control Camera Panning/Tilting ControlZooming Control Lens Iris ControlHome Position Control Preset Position ControlCamera Function Control Camera Position Control Camera Selection RecallWiper Control Mon02 Cam001 HD316 F1 F2 F3 F4 Mon01 C-P011 HD316Operating Procedure Latch mode Operating Procedure Momentary modeDefroster Control Auxiliary ControlAlarm Control System Controller Behavior during the Alarm ModeAlarm Reset Alarm SuspensionAlarm Recall HD500 Edit Group Copy Alarm Recall HD100 Alarm Recall HD200 EditOperation WJ-HD100 Series Menu Function Descriptions Menu FlowCamera Functions CAM Menu Function CategoriesRecorder Functions HDD System Functions SYS ControllerJoystick Button Functions J/S Menu To Recall Menu Functions To Assign Menu Functions to Function Buttons Mon02 Cam128 HD316 F1 F2 F3 F4 Camera Setup Off Rst To Assign Menu Functions to Joystick Function ButtonsTo Recall Button Functions and Joystick Button Functions Camera Function Assign a Code=Function Check Camera Setup 101 To Check Button Functions and Joystick Button FunctionsCamera Setup Auto ModeBW Mode Menu Function DetailsBW Mode 103 Off Auto1 Auto2 Patrol LearnPatrol Learn 104 Start Stop Patrol Learn Pre03 Start StopAuto Pan Setup and Activation Repeat Playback Setting WJ-HD300 Series OnlyRecorder Functions Disk Selection WJ-HD300 Series OnlySystem Setup System FunctionsFiltering ON/OFF WJ-HD300 Series Only Displaying Camera and Playback Image WJ-HD500 Series OnlyMux Still 305 Input Still CH 304Mux Still Enter F1 Button Controller Functions Camera CleaningTime & Date Search Display Pattern Auto Login/Logout Setup Operator Registration or Change Function Level Setting Camera Level Setting Camera Position Registration or Clearing Associating Camera Numbers with Unit Numbers Associating Recorder Numbers with Unit Numbers LCD Title Editing Camera Function Joystick Button FunctionsSystem Function Auto Pan Camera SortCamera Sequence Patrol PlayIris Reset Home PositionAuto Focus Camera +1Repeat Playback WJ-HD300 Series Only CameraRecorded-image Copy WJ-HD500 Series Only Alarm Search WJ-HD200 Series / WJ-HD100 Series Multiscreen DisplayTroubleshooting Problem Check item and Remedy ReferenceProblem Check item and Remedy Reference Specifications Standard AccessoriesSystem Controller Data PortPage 2004