Panasonic WV-CU650 operating instructions Monitor Selection, Camera Selection

Page 32

Monitor Selection

When two or more monitors are connected to a system unit, you can select a desired monitor.

When monitor selection is unavailable, “Mon- -“ appears on the LCD. The selected system unit does not support moni- tor selection.

1.Select a system unit (including a recorder) connected to a monitor you wish to control. (Refer to p. 31 System Unit Selection.)

Mon01 Cam016 HD316

F1 F2 F3 F4

2.Select the desired monitor number by pressing the numeric buttons. The entered number will appear on the LCD.

Mon01 Cam016 ___16

F1 F2 F3 F4

Note: Refer to the operating instructions of system unit for available monitor numbers.

3.Press the MON (ESC) button. The monitor number will appear on the LCD. The system will become ready for monitor control.

Mon02 Cam016 HD316

F1 F2 F3 F4

Note: If you have entered a wrong monitor number, “Invalid” will appear on the LCD. Then, the LCD will return to the status before the monitor selection.

Mon02 Cam016 HD316

Invalid

Camera Selection

When two or more cameras are connected to a system unit, you can select a desired camera. You will also perform camera selection when changing camera channels.

1.Select a system unit and monitor connected to a cam- era you wish to control. (Refer to p. 31 System Unit Selection and Monitor Selection in this page.)

Mon01 Cam001 HD316

F1 F2 F3 F4

Note: If camera numbers are associated with unit num- bers, you can skip system unit selection. (Refer to p. 66 Associating Camera Numbers with Unit Numbers.)

2.Select a camera number by pressing the numeric but- tons. The entered number will appear on the LCD.

Mon01 Cam001 ____16

F1 F2 F3 F4

Notes:

Refer to the operating instructions of system unit for available camera numbers.

You can also select cameras by pressing the + or – button. When pressing the + button, the monitor will display the image of camera with the higher chan- nel number. When pressing the – button, the moni- tor will display the image of camera with the lower channel number.

3.Press the CAM (SET) button. The system will become ready for control. Then, the camera number will appear on the LCD, and the image of selected camera will be displayed on the active monitor.

Mon01 Cam016 HD316

F1 F2 F3 F4

Note: If you have entered a wrong camera number (other than 1 to 999), “Invalid” will appear on the LCD. Then, the LCD will return to the status before selecting the camera.

Mon01 Cam016 HD316

Invalid

Signs displayed on the LCD

“Seq”: This sign is displayed when a sequence is acti- vated.

“Seq-P”:This sign is displayed when a sequence is paused.

“C-Pnnn*”:This sign is displayed when a camera posi- tion is selected. (Camera position is the combina- tion of camera number and preset position num- ber.) * nnn is a camera position number.

32

Image 32
Contents Operating Instructions English Version Important Safety Instructions Contents Features PrefacePrecautions Limitation of LiabilityDo not drop metallic parts through slots Do not attempt to disassemble the applianceDocument Convention Notification about System UnitsMain Unit Front View0Alarm recall button ALM Recall Camera function/System function button1On-screen display button OSD 2Monitor lock/Logout button MON LOCK/LOGOUT#3Preset/Program preset button PRESET/PGM #9Adjustment button Adjust@8Shuttle hold button Shuttle Hold @9History button HistoryRear View 3D Joystick Unit Mon02 Cam016 HD316 Default Status LCD Display After LoginLCD Display Descriptions Blinking Main Menu Menu FunctionsSub Menu Menu Functions Controller No.1 No Exist Error Messages Displayed on the LCDInvalid Mon02 Cam016 HD316 BusyInstallations and Connections Basic System ConnectionsAdjustment of 3D Joystick Connection with the 3D Joystick UnitSetup Procedures Hardware Setup ProceduresMode Switch Setting Controller NO. Switch SettingSetup Procedures Firmware Administrator Password EntrySetting Modes Setting Mode DescriptionOperation All ResetPS·Data Communication Setting Baud Rate Setting Wait Time Setting Parity Bit SettingStop Bit Setting Group Address Setting for System Controller Group Address Setting for System UnitsTo Change the Administrator Password Database Copy PS·Data Operator Password Check Data Base Rx Mode Completed Sum=1733PSD Password Check Admin Password PSD Password Check Admin Password ∗ ∗ ∗ ∗ ∗Before Operation Power-onPower-off LCD/BUZZER Adjustment Buzzer AlarmBasic Operation Flow LCD BrightOperation Start Login If You Have Forgotten the Login Password Operation Start Auto LoginPS Data Mode Auto Login Logout PS·Data Mode No UserRecorder Selection Unit SelectionSystem Unit Selection Monitor Selection Camera SelectionSystem Unit Control Multiscreen DisplayElectronic Zooming Tour Sequence/Group SequenceSystem Function Control How to Display Search Lists Recorder ControlManual Recording Search PlaybackSearch Mode HD300 List Text Copy Nr-A Cp-A Cpy1 Cpy2 Example of searching filter display and settingsOperation WJ-HD300 Series Available buttons and functionsSearch Mode HD500 Edit Group Alm Copy Search Mode HD500 DriveOperation WJ-HD500 Series LCD displaySearch Mode HD200 Time & Date Search PlaybackOperation WJ-HD200 Series Mmm/DD/YYYY Hhmm Mar/16/2004 0132 PMOther Available Functions Camera Control Camera Panning/Tilting ControlZooming Control Lens Iris ControlCamera Function Control Preset Position ControlHome Position Control Camera Position Control Camera Selection RecallWiper Control Mon02 Cam001 HD316 F1 F2 F3 F4 Mon01 C-P011 HD316Operating Procedure Latch mode Operating Procedure Momentary modeDefroster Control Auxiliary ControlAlarm Control System Controller Behavior during the Alarm ModeAlarm Reset Alarm SuspensionAlarm Recall HD500 Edit Group Copy Operation WJ-HD100 Series Alarm Recall HD200 EditAlarm Recall HD100 Menu Function Descriptions Menu FlowRecorder Functions HDD Menu Function CategoriesCamera Functions CAM System Functions SYS ControllerJoystick Button Functions J/S Menu To Recall Menu Functions To Assign Menu Functions to Function Buttons Mon02 Cam128 HD316 F1 F2 F3 F4 Camera Setup Off Rst To Assign Menu Functions to Joystick Function ButtonsTo Recall Button Functions and Joystick Button Functions Camera Function Assign a Code=Function Check Camera Setup 101 To Check Button Functions and Joystick Button FunctionsCamera Setup Auto ModeBW Mode Menu Function DetailsBW Mode 103 Off Auto1 Auto2 Patrol LearnPatrol Learn 104 Start Stop Patrol Learn Pre03 Start StopAuto Pan Setup and Activation Repeat Playback Setting WJ-HD300 Series OnlyRecorder Functions Disk Selection WJ-HD300 Series OnlySystem Setup System FunctionsFiltering ON/OFF WJ-HD300 Series Only Displaying Camera and Playback Image WJ-HD500 Series OnlyMux Still Enter F1 Button 304Mux Still 305 Input Still CH Time & Date Search Display Pattern Camera CleaningController Functions Auto Login/Logout Setup Operator Registration or Change Function Level Setting Camera Level Setting Camera Position Registration or Clearing Associating Camera Numbers with Unit Numbers Associating Recorder Numbers with Unit Numbers LCD Title Editing System Function Joystick Button FunctionsCamera Function Auto Pan Camera SortCamera Sequence Patrol PlayIris Reset Home PositionAuto Focus Camera +1Recorded-image Copy WJ-HD500 Series Only CameraRepeat Playback WJ-HD300 Series Only Alarm Search WJ-HD200 Series / WJ-HD100 Series Multiscreen DisplayTroubleshooting Problem Check item and Remedy ReferenceProblem Check item and Remedy Reference Specifications Standard AccessoriesSystem Controller Data PortPage 2004