Panasonic WJ-SX650 Recorder Settings, System Controller Connection, Terminal Mode Connection

Page 34

Recorder Settings

Be sure to perform the settings for connected recorders in SETUP MENU of recorders.

You can set w to t before starting operation. However, you must set q separately for each recorder before con- nections. The settings are performed in SETUP MENU (Advanced).

qUnit Address (System)

Set the Unit Address (System) for each recorder in "Comm" – "PS.Data Setup". 001 to 016 are available. (Up to 16 recorders can be connected.) The unit address setting must be different each other.

wUnit Address (Controller)

Set the Unit Address (Controller) for each recorder in "Comm" – "PS.Data Setup". 001 to 004 are available. (Up to 4 recorders can be connected to a DATA port.) The unit address setting must be different each other.

eCamera Number Setup

Perform the Camera Number Setting for each recorder in "Comm" – "PS.Data Setup. The camera number set- tings must be identical as the LCN settings of this unit.

Example: To supply video input signal from Camera 999 to the CAMERA IN 16 connector of Recorder 16 (Unit Address (System): 16), select CAM NO. 999 for CAM PORT 16.

rCamera Control

Select PSD for CAM1 to CAM16 in "Comm" – "Camera Control".

tEvent REC

To activate alarm recording, perform the event record- ing settings surely. Refer to the operating instructions of recorders for details.

Maintain the factory default for the following settings.

PSD User setting in "System" – "Basic Setup": ADMIN

Operation Mode setting of each Event Program – VMD, VIDEO LOSS, and Terminal/Command Alarm in "Schedule" – "Event Program": ALARM

(When setting QUICK for REC Type, Operation Mode setting of Event REC in "SETUP MENU (Quick)" – "REC & Event": ALARM)

Settings in "Comm" – "PS.Data Setup" of SETUP MENU, except for q to e.

System Controller Connection

The following is a connection example to use system con- trollers.

There are two options to connect system controllers to this unit.

Terminal mode: Normally, this operation mode is applied.

PS·Data mode: When other system units are connected to this unit, and they are controlled by the same system controller, this operation mode is applied. This mode has operation restrictions. Refer to p. 48 OPERATION (OTHER THAN TERMINAL MODE.

Terminal Mode Connection

To apply the terminal mode, connect the system controllers as follows.

1.Connect the system controllers to the DATA 1 to 4 ports of the unit.

Notes:

In the factory default, the DATA 3 and 4 ports are set to HDR1 for recorder connection. To connect system controllers, perform the DATA port settings in SETUP MENU (refer to p. 90) or WJ-SX650 Series Administrator Console.

Both of recorders and system controllers cannot be connected to the same DATA port.

By connecting up to 4 system controllers to one DATA port in the daisy chain, up to 16 system con- trollers are available in the system. (However, up to 16 system controllers can log into the system at a time.)

Daisy chain connection is available with System Controller WV-CU950/650 (Ver. 2.00 or later).

2.Set the system controllers to the terminal mode. (Refer to the operating instructions of system controllers.)

3.Set the CONTROLLER NO. switches of system con- trollers to 1. (In the daisy chain connection, set 1 to 4 for each controller. The switch setting must be different from each other. However, when connecting system controllers to different DATA ports, you can use over- lapped controller numbers.)

Note: Refer to the operating instructions of system con- troller for details on the CONTROLLER NO. switch setting.

34

Image 34
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Limitation of Liability Disclaimer of WarrantyTrademarks and Registered Trademarks Precautions About These Operating Instructions Preparations pages xx, xx, xxTimer event and camera event can be scheduled FeaturesAuthentication by user IDs, passwords, and level settings Alarm operation and alarm event can be scheduledWJ-SX650 Matrix Switcher/WJ-SX650U Card Cage Front View1Signal Ground Terminal Signal GND Rear ViewX-2 board Video Input Board WJ-PB65C32A-3/IN B-3/IN C-3 board IN-3 boardOUT X-2 board Video Output Board WJ-PB65M16OUT X-3 board OUT X-1 boardMonitor Display Information System Controller Display Information WV-CU950/650WV-CU360C/CJ Camera/recorder/sequence number 001 to 999 Camera numberInstallations Checking Board CompositionSwitch Settings for Video Input Main Board Front view of video output main board Switch Settings for Video Output Main BoardHost Func Mounting Video Input and Output Boards Board Mounting Procedure Rack Mounting Installing the Main UnitPlaces to avoid EIA equivalents Products of other manufacturers EIARecommended ConnectionsStandards Basic System Connections This unit x 1, camera x 30, monitor x 16, and recorder xExpanded System Connections This unit x 3, camera x 150, monitor x 32, and recorder xThis unit x 4, camera x 240, monitor x 32, and recorder x Card Cage Connections Line termination OFFRS-485 Camera Connections Camera ConnectionsOFF Daisy Chain Connection ConnectionWV-CA48/JN Monitor Connections PC ConnectionRecorder Connection Connection to Video Output Connectors of RecordersRecorders unit address Camera in channel Video input board Video OUT Recorder number Unit Address SystemConnection between Recorders and Video Input Boards OFF Terminal Mode Connection Recorder SettingsSystem Controller Connection PS·Data Mode Connection ExamplePin No Designation Alarm Sensor ConnectionsExternal Device Connections GNDDisplay example of System Status System Status CheckTerminal Duration Remarks MonitorRecorder 1 to 10 on Recorder 11 to 16 OFF Setup ProcedureSetup Menu Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation WJ-SX650 Series Administrator ConsoleInstallation and Uninstallation UninstallationWindow Details User Name admin Password sx650Starting Up Tool BarTooltip Details Reference No Explanation2005 to 2099 Year ON, OFF, AUTO, B/W setting Camera SystemDisplay SequenceSchedule AlarmOperator Controller CommunicationBasic Operations Setup Menu OSDTop Menu Month Alarm MenuYear Day TimeTerminal Alarm Menu Recorder AlarmInput Board 800 bps/9 600 bps/19 200 bps/38 400 bps System MenuData Port Menu Data bit 8 bits Parity check None Stop bit 1 bitVD2 VD2/DATA/CABLE Compensation MenuRS485 Camera Menu RS485Information Login and Logout Operator RegistrationOperation Start/End Auto Login/Logout Power-on/offOperation Start Login Operation End LogoutMonitor Selection Monitor ControlMonitor Lock Camera Selection Preset Position ControlCamera Control Camera Selection RecallAll Cameras Control Available buttons and functions F1 All home positionsRecorder Control Recorder Control End Recorder SelectionDescriptions of Sequence Group PresetRunning Sequence Tour SequenceSequence Setting Setting item Parameter RemarksGroup Sequence/Preset Tour SequenceAvailable operations during sequence pause Sequence PauseSequence Stop Sequence step forward/backwardAlarm Occurrence Alarm DescriptionsTerminal alarm setting Video Loss Alarm ModesGroup Sequence/Preset SpotAlarm Control Alarm History Display Return to Alarm Mode StatusAlarm Suspension Details on Alarm History DisplayREC Camera Event Timer DescriptionsTimer Event Auto TrackBW and Scene Patrols Alarm in Camera Not UseCleaning Scene PatrolsLists of Operations and Functions Terminal Mode OperationAlarm recover WV-CU950/650 Operation list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV Function list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 CU360C/CJCAM ID Shift + SetupALL EventALM Recall ALM ResetShift + ALM ALL Reset Shift + ALL Reset ACKCamera control Focus FAR + Focus Focus FARFocus Near NearWiper DEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF Recorder controlShift + CAM Func → Multi Screen OSDOSD ON/OFF Screen SELGO to Last PlayPause StopRecorder + If you select a recorder, and then press the Menu button Menu Flow WV-CU950/650If you press the Menu button without selecting a recorder If you select a recorder, and then press the Search buttonOperation Other than Terminal Mode PS·Data Mode OperationsControlling from a PC Controlling from a Web Browser Accessing a RecorderConnections and Operations Glossary Camera Access Refer to p Recorder Access Refer to pAlarm event Refer to p Monitor lock Refer to pPage Troubleshooting Matrix Switcher WJ-SX650 SeriesCoaxial communication RS-485 communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Power Cord, Connectors, and Power Plug Problem Check item and remedy ReferenceSpecifications Matrix Switcher WJ-SX650 SeriesVideo Input Board WJ-PB65C21 Card Cage WJ-SX650UVideo Output Board WJ-PB65M16 Sub/BNC Video Cable WJ-CA68 Standard AccessoriesExpansion Cable Kit WJ-CA65L20K/WJ-CA65L07K CD-ROMN0805-0 V8QA6300AN