Panasonic WJ-SX650 manual Alarm Control

Page 68

ALARM CONTROL

Alarm Acknowledgement (ACK)

By acknowledging an alarm occurrence on an associated monitor, you can control alarm pictures.

WV-CU950/650

While a monitor in the alarm mode status is selected, press the ACK button. (During the alarm mode status, "Alarm" sign is blinking on the LCD.)

The alarm event will be acknowledged. ("Alarm" sign will change to steady light.)

WV-CU360C/CJ

While a monitor in the alarm mode status is selected, press the ACK button. (During the alarm mode status, the alarm number is blinking on the LCD.)

The alarm will be acknowledged. (The alarm number will change to steady light.)

In the ACK status, the following operations are available.

Camera Control

You can control panning/tilting of cameras, or move cam- eras to preset positions.

Alarm Picture Change

When two or more alarms are occurring, you can change alarm pictures displayed on the monitor in order or reverse order.

WV-CU950/650

To change alarm pictures on the monitor, press the + or – button. The alarm pictures will be displayed in order or reverse order.

WV-CU360C/CJ

To change alarm pictures on the monitor, press the NEXT or PREV button. The alarm pictures will be displayed in order or reverse order.

Alarm Individual Reset

You can reset each acknowledged alarm separately, and return to the status before alarm occurrence. While two or more alarms are occurring, the system will remain in the alarm mode even after an alarm reset.

To reset an acknowledged alarm, press the ACK button. The alarm will be reset.

Notes:

If the alarm event is set to OFF, an alarm will not be acknowledged. The alarm will be reset by every press- ing the ACK button.

If AUTO RESET has been set to ON, alarms will be reset automatically after the specified time. Refer to p. 86 ALARM of SETUP MENU.

Alarm Monitor Reset

You can reset all the alarms occurred to the selected moni- tor.

While the selected monitor is in the alarm mode status, press the ALM RESET*1 (or RESET*2) button. All the alarms occurred to the monitor will be reset, and the monitor dis- play will return to the status before the alarm occurrence.

*1 WV-CU950/650

*2 WV-CU360C/CJ

Note: Alarm monitor reset is also available by supplying alarm recover signals to the unit.

Alarm All Reset

You can reset all the alarms occurred to the system.

WV-CU950/650

Press the ALM ALL RESET*1 (or ALL RESET*2) button while holding down the SHIFT button. All the alarms occurred to the system will be reset.

*1 WV-CU950/650

*2 WV-CU360C/CJ

68

Image 68
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Trademarks and Registered Trademarks Disclaimer of WarrantyLimitation of Liability Precautions About These Operating Instructions Preparations pages xx, xx, xxFeatures Authentication by user IDs, passwords, and level settingsTimer event and camera event can be scheduled Alarm operation and alarm event can be scheduledWJ-SX650 Matrix Switcher/WJ-SX650U Card Cage Front View1Signal Ground Terminal Signal GND Rear ViewVideo Input Board WJ-PB65C32 A-3/IN B-3/IN C-3 boardX-2 board IN-3 boardVideo Output Board WJ-PB65M16 OUT X-3 boardOUT X-2 board OUT X-1 boardMonitor Display Information System Controller Display Information WV-CU950/650WV-CU360C/CJ Camera/recorder/sequence number 001 to 999 Camera numberInstallations Checking Board CompositionSwitch Settings for Video Input Main Board Host Func Switch Settings for Video Output Main BoardFront view of video output main board Mounting Video Input and Output Boards Board Mounting Procedure Installing the Main Unit Places to avoidRack Mounting EIA equivalents Products of other manufacturers EIAStandards ConnectionsRecommended Basic System Connections This unit x 1, camera x 30, monitor x 16, and recorder xExpanded System Connections This unit x 3, camera x 150, monitor x 32, and recorder xThis unit x 4, camera x 240, monitor x 32, and recorder x Card Cage Connections Line termination OFFOFF Camera ConnectionsRS-485 Camera Connections WV-CA48/JN ConnectionDaisy Chain Connection Monitor Connections PC ConnectionRecorders unit address Camera in channel Video input board Connection to Video Output Connectors of RecordersRecorder Connection Video OUT Recorder number Unit Address SystemConnection between Recorders and Video Input Boards OFF System Controller Connection Recorder SettingsTerminal Mode Connection PS·Data Mode Connection ExampleAlarm Sensor Connections External Device ConnectionsPin No Designation GNDSystem Status Check Terminal Duration RemarksDisplay example of System Status MonitorSetup Procedure Setup MenuRecorder 1 to 10 on Recorder 11 to 16 OFF Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu WJ-SX650 Series Administrator Console Installation and UninstallationInstallation UninstallationUser Name admin Password sx650 Starting UpWindow Details Tool BarTooltip Details Reference No Explanation2005 to 2099 Year ON, OFF, AUTO, B/W setting System DisplayCamera SequenceOperator AlarmSchedule Controller CommunicationTop Menu Setup Menu OSDBasic Operations Alarm Menu YearMonth Day TimeTerminal Alarm Menu Recorder AlarmInput Board System Menu Data Port Menu800 bps/9 600 bps/19 200 bps/38 400 bps Data bit 8 bits Parity check None Stop bit 1 bitVD2/DATA/CABLE Compensation Menu RS485 Camera MenuVD2 RS485Information Login and Logout Operator RegistrationPower-on/off Operation Start LoginOperation Start/End Auto Login/Logout Operation End LogoutMonitor Lock Monitor ControlMonitor Selection Preset Position Control Camera ControlCamera Selection Camera Selection RecallAll Cameras Control Available buttons and functions F1 All home positionsRecorder Control Recorder Control End Recorder SelectionGroup Preset Running SequenceDescriptions of Sequence Tour SequenceSequence Setting Setting item Parameter RemarksGroup Sequence/Preset Tour SequenceSequence Pause Sequence StopAvailable operations during sequence pause Sequence step forward/backwardTerminal alarm setting Alarm DescriptionsAlarm Occurrence Alarm Modes Group Sequence/PresetVideo Loss SpotAlarm Control Return to Alarm Mode Status Alarm SuspensionAlarm History Display Details on Alarm History DisplayREC Timer Descriptions Timer EventCamera Event Auto TrackAlarm in Camera Not Use CleaningBW and Scene Patrols Scene PatrolsTerminal Mode Operation Alarm recover WV-CU950/650Lists of Operations and Functions Operation list of WV-CU950/650 and WV-CU360C/CJFunction list of WV-CU950/650 and WV-CU360C/CJ Function WV-CU950/650WV-CU950/650, WV CU360C/CJShift + Setup ALLCAM ID EventALM Reset Shift + ALM ALL Reset Shift + ALL ResetALM Recall ACKCamera control Focus FAR Focus NearFocus FAR + Focus NearWiper Shift + CAM Func Recorder controlDEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF OSD OSD ON/OFF→ Multi Screen Screen SELPlay PauseGO to Last StopRecorder + Menu Flow WV-CU950/650 If you press the Menu button without selecting a recorderIf you select a recorder, and then press the Menu button If you select a recorder, and then press the Search buttonOperation Other than Terminal Mode PS·Data Mode OperationsConnections and Operations Controlling from a Web Browser Accessing a RecorderControlling from a PC Camera Access Refer to p Recorder Access Refer to p Alarm event Refer to pGlossary Monitor lock Refer to pPage Troubleshooting Matrix Switcher WJ-SX650 SeriesCoaxial communication RS-485 communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Power Cord, Connectors, and Power Plug Problem Check item and remedy ReferenceSpecifications Matrix Switcher WJ-SX650 SeriesVideo Output Board WJ-PB65M16 Card Cage WJ-SX650UVideo Input Board WJ-PB65C21 Standard Accessories Expansion Cable Kit WJ-CA65L20K/WJ-CA65L07KSub/BNC Video Cable WJ-CA68 CD-ROMN0805-0 V8QA6300AN