Panasonic WJ-SX650 manual System Status Check, Terminal Duration Remarks, Monitor, TEM Status

Page 37

Terminal

Duration

Remarks

Alarm Output 1 to

Until reset

Open Collector

32

 

output, 16 V,

 

 

100 mA maximum

 

 

 

Alarm Recover

100 or more ms

Non-voltage make

Input 1 to 16

 

contact output

 

 

 

Time Adjust

1 second

Open Collector

Output

 

output, 16 V,

 

 

100 mA maximum

 

 

 

Time Adjust Input

100 or more ms

Non-voltage make

 

 

contact input

 

 

 

System Status Check

During connection procedures, system status can be checked on 4 monitors.

The following examples are procedures to display the sys- tem status on Monitor 1 to 4.

WV-CU950/650

1.Select one of Monitor 1 to 4. (Refer to p. 21 Monitor Selection.)

2.Press the MENU button repeatedly until "System Status" appears on the LCD.

3.Press the F1 button. SYSTEM STATUS will be displayed on Monitor 1 to 4.

Note: SYSTEM STATUS is displayed on a set of 4 monitors (Monitor 5 to 8, Monitor 9 to 12...Monitor 29 to 32).

WV-CU360C/CJ

1.Select one of Monitor 1 to 4. (Refer to p. 21 Monitor Selection.)

2.Press the OSD and SYS S buttons at a time. SYSTEM STATUS will be displayed on Monitor 1 to 4.

Note: SYSTEM STATUS is displayed on a set of 4 monitors (Monitor 5 to 8, Monitor 9 to 12...Monitor 29 to 32).

Display example of SYSTEM STATUS

<Monitor 1>

LCN, MODE, KB and OPE parameters are highlighted for monitors during the alarm mode status.

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

STATUS

 

 

 

 

 

 

MON

LCN

MODE

 

KB

OPE

PRI

 

01

001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

002

 

 

 

K1-1

123

01

 

03

200

 

 

 

 

 

 

03

 

04

030

 

 

 

 

/T001

99

 

05

100

 

G08

PC

999

14

 

06

 

 

SETUP

K1-4

5

00

 

07

 

 

HISTORY

K3-2

10

02

 

08

R16

 

 

 

 

505

03

 

LCN:LOGICAL

 

CAMERA

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCN and MODE parameters are highlighted for monitors during the alarm ACK status.

<Monitor 4>

 

SYSTEM

STATUS

 

 

 

 

 

MON

 

LCN

MODE

KB

OPE

PRI

 

25

 

 

 

 

 

 

 

 

26

075

 

PSD

48

02

 

27

105

T32

 

/T128

60

 

28

 

002

T01

K6-3

3

 

05

 

29

301

G32

 

12345

10

 

30

401

G32

 

12345

10

 

31

501

G32

K8-4

12345

10

 

32

999

 

 

 

 

 

 

LCN:LOGICAL

CAMERA

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

MON: Monitor number

LCN: Camera number or recorder number

MODE: Display mode of the monitor

SETUP: System Setup

HISTORY: Alarm History Display KB: System controller or PC

OPE: User ID of the operator or timer event No.

PRI: Operator priority

When SETUP MENU is displayed, "0" appears on this area.

During monitor lock, this area is highlighted.

Notes:

Even while SYSTEM STATUS is being displayed on monitors, normal operations and alarm control are avail- able. However, you cannot check the camera or record- ed images because black screen is displayed. It is rec- ommended to use these monitors only to check SYS-

TEM STATUS.

Up to 100 records of SYSTEM STATUS are saved in the system. These records can be transmitted between PC and this unit. (Periodical transmission is also available.) For transmission, perform the serial command settings in "Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.

To transmit SYSTEM STATUS records from the PC, refer to Serial (RS-232C) Connector Command Reference (PDF file on the supplied CD-ROM).

37

Image 37
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Limitation of Liability Disclaimer of WarrantyTrademarks and Registered Trademarks Precautions Preparations pages xx, xx, xx About These Operating InstructionsAuthentication by user IDs, passwords, and level settings FeaturesTimer event and camera event can be scheduled Alarm operation and alarm event can be scheduledFront View WJ-SX650 Matrix Switcher/WJ-SX650U Card CageRear View 1Signal Ground Terminal Signal GNDA-3/IN B-3/IN C-3 board Video Input Board WJ-PB65C32X-2 board IN-3 boardOUT X-3 board Video Output Board WJ-PB65M16OUT X-2 board OUT X-1 boardMonitor Display Information WV-CU950/650 System Controller Display InformationCamera/recorder/sequence number 001 to 999 Camera number WV-CU360C/CJChecking Board Composition InstallationsSwitch Settings for Video Input Main Board Front view of video output main board Switch Settings for Video Output Main BoardHost Func Mounting Video Input and Output Boards Board Mounting Procedure Places to avoid Installing the Main UnitRack Mounting EIA equivalents Products of other manufacturers EIARecommended ConnectionsStandards This unit x 1, camera x 30, monitor x 16, and recorder x Basic System ConnectionsThis unit x 3, camera x 150, monitor x 32, and recorder x Expanded System ConnectionsThis unit x 4, camera x 240, monitor x 32, and recorder x Line termination OFF Card Cage ConnectionsRS-485 Camera Connections Camera ConnectionsOFF Daisy Chain Connection ConnectionWV-CA48/JN PC Connection Monitor ConnectionsRecorder Connection Connection to Video Output Connectors of RecordersRecorders unit address Camera in channel Video input board Recorder number Unit Address System Video OUTConnection between Recorders and Video Input Boards OFF Terminal Mode Connection Recorder SettingsSystem Controller Connection Example PS·Data Mode ConnectionExternal Device Connections Alarm Sensor ConnectionsPin No Designation GNDTerminal Duration Remarks System Status CheckDisplay example of System Status MonitorSetup Menu Setup ProcedureRecorder 1 to 10 on Recorder 11 to 16 OFF Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation and Uninstallation WJ-SX650 Series Administrator ConsoleInstallation UninstallationStarting Up User Name admin Password sx650Window Details Tool BarReference No Explanation Tooltip Details2005 to 2099 Year ON, OFF, AUTO, B/W setting Display SystemCamera SequenceSchedule AlarmOperator Communication ControllerBasic Operations Setup Menu OSDTop Menu Year Alarm MenuMonth Day TimeRecorder Alarm Terminal Alarm MenuInput Board Data Port Menu System Menu800 bps/9 600 bps/19 200 bps/38 400 bps Data bit 8 bits Parity check None Stop bit 1 bitRS485 Camera Menu VD2/DATA/CABLE Compensation MenuVD2 RS485Information Operator Registration Login and LogoutOperation Start Login Power-on/offOperation Start/End Auto Login/Logout Operation End LogoutMonitor Selection Monitor ControlMonitor Lock Camera Control Preset Position ControlCamera Selection Camera Selection RecallAvailable buttons and functions F1 All home positions All Cameras ControlRecorder Control Recorder Selection Recorder Control EndRunning Sequence Group PresetDescriptions of Sequence Tour SequenceSetting item Parameter Remarks Sequence SettingTour Sequence Group Sequence/PresetSequence Stop Sequence PauseAvailable operations during sequence pause Sequence step forward/backwardAlarm Occurrence Alarm DescriptionsTerminal alarm setting Group Sequence/Preset Alarm ModesVideo Loss SpotAlarm Control Alarm Suspension Return to Alarm Mode StatusAlarm History Display Details on Alarm History DisplayREC Timer Event Timer DescriptionsCamera Event Auto TrackCleaning Alarm in Camera Not UseBW and Scene Patrols Scene PatrolsAlarm recover WV-CU950/650 Terminal Mode OperationLists of Operations and Functions Operation list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 Function list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV CU360C/CJALL Shift + SetupCAM ID EventShift + ALM ALL Reset Shift + ALL Reset ALM ResetALM Recall ACKCamera control Focus Near Focus FARFocus FAR + Focus NearWiper DEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF Recorder controlShift + CAM Func OSD ON/OFF OSD→ Multi Screen Screen SELPause PlayGO to Last StopRecorder + If you press the Menu button without selecting a recorder Menu Flow WV-CU950/650If you select a recorder, and then press the Menu button If you select a recorder, and then press the Search buttonPS·Data Mode Operations Operation Other than Terminal ModeControlling from a PC Controlling from a Web Browser Accessing a RecorderConnections and Operations Alarm event Refer to p Camera Access Refer to p Recorder Access Refer to pGlossary Monitor lock Refer to pPage Matrix Switcher WJ-SX650 Series TroubleshootingRS-485 communication Coaxial communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Problem Check item and remedy Reference Power Cord, Connectors, and Power PlugMatrix Switcher WJ-SX650 Series SpecificationsVideo Input Board WJ-PB65C21 Card Cage WJ-SX650UVideo Output Board WJ-PB65M16 Expansion Cable Kit WJ-CA65L20K/WJ-CA65L07K Standard AccessoriesSub/BNC Video Cable WJ-CA68 CD-ROMN0805-0 V8QA6300AN