Panasonic WJ-SX650 manual Monitor Control, Monitor Selection, Monitor Lock

Page 57

MONITOR CONTROL

The following is the procedure examples for monitor selec- tion. Refer to p. 36 Lists of Functions and Operations for other monitor control procedures not described here.

Monitor Selection

In the following procedure, you can display camera images or perform setup procedures on a desired monitor.

1.Enter the desired monitor number by pressing the numeric buttons. The entered number will appear on the LCD.

<WV-CU950/650><WV-CU360C/360CJ>

2.Press the MON (ESC) button. The specified monitor will be selected, and the system will become ready for monitor control.

<WV-CU950/650><WV-CU360C/360CJ>

3. Control the selected monitor.

Monitor Lock

When you log out of the system or select another monitor, this function can prevent operators with lower priority from gaining control of the selected monitor and camera(s).

WV-CU950/650

1.Press the MON LOCK button. The selected monitor will be locked.

2.To release the monitor lock, press the MON LOCK but- ton again.

WV-CU360C/CJ

1.Press the MON LOCK button while holding down the SHIFT button.

The selected monitor will be locked.

2.To release the monitor lock, press the MON LOCK but- ton again.

Notes:

Monitor lock is released when you select the monitor again, or an operator with higher priority selects the monitor.

Even after you log out of the system or select another monitor, the camera image or sequence is continuously displayed on the selected monitor.

57

Image 57
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Disclaimer of Warranty Limitation of LiabilityTrademarks and Registered Trademarks Precautions Preparations pages xx, xx, xx About These Operating InstructionsAuthentication by user IDs, passwords, and level settings FeaturesTimer event and camera event can be scheduled Alarm operation and alarm event can be scheduledFront View WJ-SX650 Matrix Switcher/WJ-SX650U Card CageRear View 1Signal Ground Terminal Signal GNDA-3/IN B-3/IN C-3 board Video Input Board WJ-PB65C32X-2 board IN-3 boardOUT X-3 board Video Output Board WJ-PB65M16OUT X-2 board OUT X-1 boardMonitor Display Information WV-CU950/650 System Controller Display InformationCamera/recorder/sequence number 001 to 999 Camera number WV-CU360C/CJChecking Board Composition InstallationsSwitch Settings for Video Input Main Board Switch Settings for Video Output Main Board Front view of video output main boardHost Func Mounting Video Input and Output Boards Board Mounting Procedure Places to avoid Installing the Main UnitRack Mounting EIA equivalents Products of other manufacturers EIAConnections RecommendedStandards This unit x 1, camera x 30, monitor x 16, and recorder x Basic System ConnectionsThis unit x 3, camera x 150, monitor x 32, and recorder x Expanded System ConnectionsThis unit x 4, camera x 240, monitor x 32, and recorder x Line termination OFF Card Cage ConnectionsCamera Connections RS-485 Camera ConnectionsOFF Connection Daisy Chain ConnectionWV-CA48/JN PC Connection Monitor ConnectionsConnection to Video Output Connectors of Recorders Recorder ConnectionRecorders unit address Camera in channel Video input board Recorder number Unit Address System Video OUTConnection between Recorders and Video Input Boards OFF Recorder Settings Terminal Mode ConnectionSystem Controller Connection Example PS·Data Mode ConnectionExternal Device Connections Alarm Sensor ConnectionsPin No Designation GNDTerminal Duration Remarks System Status CheckDisplay example of System Status MonitorSetup Menu Setup ProcedureRecorder 1 to 10 on Recorder 11 to 16 OFF Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation and Uninstallation WJ-SX650 Series Administrator ConsoleInstallation UninstallationStarting Up User Name admin Password sx650Window Details Tool BarReference No Explanation Tooltip Details2005 to 2099 Year ON, OFF, AUTO, B/W setting Display SystemCamera SequenceAlarm ScheduleOperator Communication ControllerSetup Menu OSD Basic OperationsTop Menu Year Alarm MenuMonth Day TimeRecorder Alarm Terminal Alarm MenuInput Board Data Port Menu System Menu800 bps/9 600 bps/19 200 bps/38 400 bps Data bit 8 bits Parity check None Stop bit 1 bitRS485 Camera Menu VD2/DATA/CABLE Compensation MenuVD2 RS485Information Operator Registration Login and LogoutOperation Start Login Power-on/offOperation Start/End Auto Login/Logout Operation End LogoutMonitor Control Monitor SelectionMonitor Lock Camera Control Preset Position ControlCamera Selection Camera Selection RecallAvailable buttons and functions F1 All home positions All Cameras ControlRecorder Control Recorder Selection Recorder Control EndRunning Sequence Group PresetDescriptions of Sequence Tour SequenceSetting item Parameter Remarks Sequence SettingTour Sequence Group Sequence/PresetSequence Stop Sequence PauseAvailable operations during sequence pause Sequence step forward/backwardAlarm Descriptions Alarm OccurrenceTerminal alarm setting Group Sequence/Preset Alarm ModesVideo Loss SpotAlarm Control Alarm Suspension Return to Alarm Mode StatusAlarm History Display Details on Alarm History DisplayREC Timer Event Timer DescriptionsCamera Event Auto TrackCleaning Alarm in Camera Not UseBW and Scene Patrols Scene PatrolsAlarm recover WV-CU950/650 Terminal Mode OperationLists of Operations and Functions Operation list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 Function list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV CU360C/CJALL Shift + SetupCAM ID EventShift + ALM ALL Reset Shift + ALL Reset ALM ResetALM Recall ACKCamera control Focus Near Focus FARFocus FAR + Focus NearWiper Recorder control DEF on Shift + DEF on OFF DEF OFF Shift + DEF OFFShift + CAM Func OSD ON/OFF OSD→ Multi Screen Screen SELPause PlayGO to Last StopRecorder + If you press the Menu button without selecting a recorder Menu Flow WV-CU950/650If you select a recorder, and then press the Menu button If you select a recorder, and then press the Search buttonPS·Data Mode Operations Operation Other than Terminal ModeControlling from a Web Browser Accessing a Recorder Controlling from a PCConnections and Operations Alarm event Refer to p Camera Access Refer to p Recorder Access Refer to pGlossary Monitor lock Refer to pPage Matrix Switcher WJ-SX650 Series TroubleshootingRS-485 communication Coaxial communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Problem Check item and remedy Reference Power Cord, Connectors, and Power PlugMatrix Switcher WJ-SX650 Series SpecificationsCard Cage WJ-SX650U Video Input Board WJ-PB65C21Video Output Board WJ-PB65M16 Expansion Cable Kit WJ-CA65L20K/WJ-CA65L07K Standard AccessoriesSub/BNC Video Cable WJ-CA68 CD-ROMN0805-0 V8QA6300AN