Panasonic WJ-SX650 manual Rec

Page 70

T01 to 32: Tour Sequence 1 to 32 was activated.

G01 to 32: Group sequence (or Group preset) 1 to 32 was activated.

Notes:

User ID and Controller No. is displayed for an alarm reset or suspended by an operator. (They are not displayed for auto reset.)

User ID and controller No. will be highlighted to indicate alarm reset or alarm suspension OFF.

REC

"Recording Source (LCN)" associated with the alarm event is displayed.

Refer to p. 36 Lists of Functions and Operations for opera- tions while the Alarm History Display is displayed on the monitor.

70

Image 70
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Limitation of Liability Disclaimer of WarrantyTrademarks and Registered Trademarks Precautions About These Operating Instructions Preparations pages xx, xx, xxTimer event and camera event can be scheduled FeaturesAuthentication by user IDs, passwords, and level settings Alarm operation and alarm event can be scheduledWJ-SX650 Matrix Switcher/WJ-SX650U Card Cage Front View1Signal Ground Terminal Signal GND Rear ViewX-2 board Video Input Board WJ-PB65C32A-3/IN B-3/IN C-3 board IN-3 boardOUT X-2 board Video Output Board WJ-PB65M16OUT X-3 board OUT X-1 boardMonitor Display Information System Controller Display Information WV-CU950/650WV-CU360C/CJ Camera/recorder/sequence number 001 to 999 Camera numberInstallations Checking Board CompositionSwitch Settings for Video Input Main Board Front view of video output main board Switch Settings for Video Output Main BoardHost Func Mounting Video Input and Output Boards Board Mounting Procedure Rack Mounting Installing the Main UnitPlaces to avoid EIA equivalents Products of other manufacturers EIARecommended ConnectionsStandards Basic System Connections This unit x 1, camera x 30, monitor x 16, and recorder xExpanded System Connections This unit x 3, camera x 150, monitor x 32, and recorder xThis unit x 4, camera x 240, monitor x 32, and recorder x Card Cage Connections Line termination OFFRS-485 Camera Connections Camera ConnectionsOFF Daisy Chain Connection ConnectionWV-CA48/JN Monitor Connections PC ConnectionRecorder Connection Connection to Video Output Connectors of RecordersRecorders unit address Camera in channel Video input board Video OUT Recorder number Unit Address SystemConnection between Recorders and Video Input Boards OFF Terminal Mode Connection Recorder SettingsSystem Controller Connection PS·Data Mode Connection ExamplePin No Designation Alarm Sensor ConnectionsExternal Device Connections GNDDisplay example of System Status System Status CheckTerminal Duration Remarks MonitorRecorder 1 to 10 on Recorder 11 to 16 OFF Setup ProcedureSetup Menu Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation WJ-SX650 Series Administrator ConsoleInstallation and Uninstallation UninstallationWindow Details User Name admin Password sx650Starting Up Tool BarTooltip Details Reference No Explanation2005 to 2099 Year ON, OFF, AUTO, B/W setting Camera SystemDisplay SequenceSchedule AlarmOperator Controller CommunicationBasic Operations Setup Menu OSDTop Menu Month Alarm MenuYear Day TimeTerminal Alarm Menu Recorder AlarmInput Board 800 bps/9 600 bps/19 200 bps/38 400 bps System MenuData Port Menu Data bit 8 bits Parity check None Stop bit 1 bitVD2 VD2/DATA/CABLE Compensation MenuRS485 Camera Menu RS485Information Login and Logout Operator RegistrationOperation Start/End Auto Login/Logout Power-on/offOperation Start Login Operation End LogoutMonitor Selection Monitor ControlMonitor Lock Camera Selection Preset Position ControlCamera Control Camera Selection RecallAll Cameras Control Available buttons and functions F1 All home positionsRecorder Control Recorder Control End Recorder SelectionDescriptions of Sequence Group PresetRunning Sequence Tour SequenceSequence Setting Setting item Parameter RemarksGroup Sequence/Preset Tour SequenceAvailable operations during sequence pause Sequence PauseSequence Stop Sequence step forward/backwardAlarm Occurrence Alarm DescriptionsTerminal alarm setting Video Loss Alarm ModesGroup Sequence/Preset SpotAlarm Control Alarm History Display Return to Alarm Mode StatusAlarm Suspension Details on Alarm History DisplayREC Camera Event Timer DescriptionsTimer Event Auto TrackBW and Scene Patrols Alarm in Camera Not UseCleaning Scene PatrolsLists of Operations and Functions Terminal Mode OperationAlarm recover WV-CU950/650 Operation list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV Function list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 CU360C/CJCAM ID Shift + SetupALL EventALM Recall ALM ResetShift + ALM ALL Reset Shift + ALL Reset ACKCamera control Focus FAR + Focus Focus FARFocus Near NearWiper DEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF Recorder controlShift + CAM Func → Multi Screen OSDOSD ON/OFF Screen SELGO to Last PlayPause StopRecorder + If you select a recorder, and then press the Menu button Menu Flow WV-CU950/650If you press the Menu button without selecting a recorder If you select a recorder, and then press the Search buttonOperation Other than Terminal Mode PS·Data Mode OperationsControlling from a PC Controlling from a Web Browser Accessing a RecorderConnections and Operations Glossary Camera Access Refer to p Recorder Access Refer to pAlarm event Refer to p Monitor lock Refer to pPage Troubleshooting Matrix Switcher WJ-SX650 SeriesCoaxial communication RS-485 communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Power Cord, Connectors, and Power Plug Problem Check item and remedy ReferenceSpecifications Matrix Switcher WJ-SX650 SeriesVideo Input Board WJ-PB65C21 Card Cage WJ-SX650UVideo Output Board WJ-PB65M16 Sub/BNC Video Cable WJ-CA68 Standard AccessoriesExpansion Cable Kit WJ-CA65L20K/WJ-CA65L07K CD-ROMN0805-0 V8QA6300AN