■TIME & DATE
You will set the current time and date.
When you select TIME & DATE on the top menu, the follow- ing menu is displayed.
Note: Display format setting is performed in "Display" –
"Display" of
100TIME&DATE Aug/31/2005 ∗08:15 PM
DST/SUMMER TIME | ON |
• Year
2005 to 2099
• Month
1 to 12 (When Date Format is set to DD/MM/YYYY, MM/DD/YYYY, YYYY/MM/DDDD in
Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec (When Date Format is set to DD/Mmm/YYYY or Mmm/DD/YYYY in
• Day
1 to 31
• Time
0 to 23(When Time Format is set to
1 to 12(When Time Format is set to
AM /PM (When Time Format is set to
• Minute
0 to 59
• DST/SUMMER TIME
ON/OFF
The factory default is as follows.
Jan/01/2005 00:00AM, DST/SUMMER TIME ON
Note: When DST/SUMMER TIME is set to ON, the daylight saving time (summer time) is activated during the spec- ified period. ("∗" is displayed beside the time.) The peri- od setting is performed in "Display" – "DST/Summer Time" of
■ALARM
You will perform the settings of alarms (terminal alarms, camera alarms, recorder alarms, serial alarms, and video loss).
When you select ALARM on the top menu, the following menu is displayed.
300 | ALARM |
|
|
|
310 | ALARM | MODE |
|
|
SEQUENCE |
| |||
| BDWELL TIME | 2sec |
| |
320 | AUTO RESET | OFF |
| |
330 | TERMINAL ALARM | ONO |
| |
340 | CAMERA | ALARM | OFF |
|
350 | RECORDER ALARM | OFF |
| |
360 | SERIAL | ALARM | ON |
|
370 | VIDEO | LOSS | ON |
|
|
|
|
|
|
●ALARM Menu
• ALARM MODE
Select the display pattern to display spot alarm pictures on the associated monitors. (The factory default is SEQUENCE.)
SEQUENCE: Alarm pictures are sequentially displayed on the associated monitor. Select desired DWELL TIME from 1 to 30 sec. (The factory default is 2 sec.)
LATEST: The latest alarm picture is displayed on the moni- tor.
EARLIEST: The earliest alarm picture is displayed on the monitor.
• AUTO RESET
Select the period until an alarm is automatically reset. If you select OFF, you will reset the alarm manually. (The factory default is 30 sec.)
OFF/1, 2... to 10 sec/20 sec/30 sec/1 min/3 min/5 min
• TERMINAL ALARM
Select ON or OFF to accept or not accept terminal alarm input signals.
ON: Accepts terminal alarm input signals.
OFF: Not accepts terminal alarm input signals.
Note: If you select ON, you can move to TERMINAL ALARM (refer to p. 85), and you can set the details on terminal alarm input signal.
• CAMERA ALARM
Select ON or OFF to accept or not accept camera alarm input signals.
ON: Accepts camera alarm input signals.
OFF: Not accepts camera alarm input signals.
49