Panasonic WJ-SX650 manual Setup Procedure, Recorder 1 to 10 on Recorder 11 to 16 OFF, Setup Menu

Page 38

SETUP PROCEDURE

Before operation, setup of this unit is required. Setup is per- formed from WJ-SX650 Series Administrator Console installed on a PC. (Some settings are available from SETUP MENU of this unit.) The following is an example of setup procedure.

Notes:

Setup may differ depending on system composition. (Settings of Step 1 and 4 in the following procedure must be performed.)

For Step 2, 3, 5 and 6 in the following setup procedure, the factory default can be maintained.

Example: camera x 150, recorder x 10, monitor x 32, and system controller x 2 (Terminal mode)

1.Perform the recorder settings.

Recorder Out: Input Board No.5 (When video input sig- nals are supplied from recorders to CAM160 to 151)

Recorder 1 to 10: ON

Recorder 11 to 16: OFF

Note: Check if recorders are properly connected to the DATA port and CAM (camera input channels) currently displayed.

<WJ-SX650 Series Administrator Console> "System" – "Recorder"

<SETUP MENU> RECORDER (Refer to p. 87.)

2.Perform the DATA port settings. (In this example, main- tain the factory default.)

DATA 1, 2, 5 and 6 ports: TMNL

DATA 3, 4, 7 and 8 ports: HDR

Note: Change these parameters when using PS·Data system controllers, etc.

<WJ-SX650 Series Administrator Console>

"System" – "DATA Port"

<SETUP MENU>

DATA PORT (Refer to p. 90.)

<WJ-SX650 Series Administrator Console>

"System" – "VD2/DATA/Cable Comp."

<SETUP MENU>

VD2/DATA/CABLE COMPENSATION (Refer to p. 91.)

3.Perform the LCN (Logical Camera Number) settings. CAM001 to 160: If you change LCN settings, select

desired parameters.

CAM161 to 256: Delete the LCN parameters.

Notes:

Set LCN parameters for CAM151 to 160 surely, even though these channels accept video input signals from recorders. Without LCN settings, recorder selection is unavailable.

By deleting the LCN parameters of unused camera channels, operators can select only existing camera numbers.

<WJ-SX650 Series Administrator Console> "System" – "Logical Camera Number"

<SETUP MENU> Not available

4.Perform the camera settings.

CAM001 to 150: Select desired parameters for these cameras. (To use cameras of other manufacturers, set DATA to OFF.) For Cable (cable compensation), select the parameter suited to the cable length.

CAM151 to 160: Set DATA to OFF. (Video input signals are supplied from recorders to these channels.)

38

Image 38
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Trademarks and Registered Trademarks Disclaimer of WarrantyLimitation of Liability Precautions About These Operating Instructions Preparations pages xx, xx, xxTimer event and camera event can be scheduled FeaturesAuthentication by user IDs, passwords, and level settings Alarm operation and alarm event can be scheduledWJ-SX650 Matrix Switcher/WJ-SX650U Card Cage Front View1Signal Ground Terminal Signal GND Rear ViewX-2 board Video Input Board WJ-PB65C32A-3/IN B-3/IN C-3 board IN-3 boardOUT X-2 board Video Output Board WJ-PB65M16OUT X-3 board OUT X-1 boardMonitor Display Information System Controller Display Information WV-CU950/650WV-CU360C/CJ Camera/recorder/sequence number 001 to 999 Camera numberInstallations Checking Board CompositionSwitch Settings for Video Input Main Board Host Func Switch Settings for Video Output Main BoardFront view of video output main board Mounting Video Input and Output Boards Board Mounting Procedure Rack Mounting Installing the Main UnitPlaces to avoid EIA equivalents Products of other manufacturers EIAStandards ConnectionsRecommended Basic System Connections This unit x 1, camera x 30, monitor x 16, and recorder xExpanded System Connections This unit x 3, camera x 150, monitor x 32, and recorder xThis unit x 4, camera x 240, monitor x 32, and recorder x Card Cage Connections Line termination OFFOFF Camera ConnectionsRS-485 Camera Connections WV-CA48/JN ConnectionDaisy Chain Connection Monitor Connections PC ConnectionRecorders unit address Camera in channel Video input board Connection to Video Output Connectors of RecordersRecorder Connection Video OUT Recorder number Unit Address SystemConnection between Recorders and Video Input Boards OFF System Controller Connection Recorder SettingsTerminal Mode Connection PS·Data Mode Connection ExamplePin No Designation Alarm Sensor ConnectionsExternal Device Connections GNDDisplay example of System Status System Status CheckTerminal Duration Remarks MonitorRecorder 1 to 10 on Recorder 11 to 16 OFF Setup ProcedureSetup Menu Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation WJ-SX650 Series Administrator ConsoleInstallation and Uninstallation UninstallationWindow Details User Name admin Password sx650Starting Up Tool BarTooltip Details Reference No Explanation2005 to 2099 Year ON, OFF, AUTO, B/W setting Camera SystemDisplay SequenceOperator AlarmSchedule Controller CommunicationTop Menu Setup Menu OSDBasic Operations Month Alarm MenuYear Day TimeTerminal Alarm Menu Recorder AlarmInput Board 800 bps/9 600 bps/19 200 bps/38 400 bps System MenuData Port Menu Data bit 8 bits Parity check None Stop bit 1 bitVD2 VD2/DATA/CABLE Compensation MenuRS485 Camera Menu RS485Information Login and Logout Operator RegistrationOperation Start/End Auto Login/Logout Power-on/offOperation Start Login Operation End LogoutMonitor Lock Monitor ControlMonitor Selection Camera Selection Preset Position ControlCamera Control Camera Selection RecallAll Cameras Control Available buttons and functions F1 All home positionsRecorder Control Recorder Control End Recorder SelectionDescriptions of Sequence Group PresetRunning Sequence Tour SequenceSequence Setting Setting item Parameter RemarksGroup Sequence/Preset Tour SequenceAvailable operations during sequence pause Sequence PauseSequence Stop Sequence step forward/backwardTerminal alarm setting Alarm DescriptionsAlarm Occurrence Video Loss Alarm ModesGroup Sequence/Preset SpotAlarm Control Alarm History Display Return to Alarm Mode StatusAlarm Suspension Details on Alarm History DisplayREC Camera Event Timer DescriptionsTimer Event Auto TrackBW and Scene Patrols Alarm in Camera Not UseCleaning Scene PatrolsLists of Operations and Functions Terminal Mode OperationAlarm recover WV-CU950/650 Operation list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV Function list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 CU360C/CJCAM ID Shift + SetupALL EventALM Recall ALM ResetShift + ALM ALL Reset Shift + ALL Reset ACKCamera control Focus FAR + Focus Focus FARFocus Near NearWiper Shift + CAM Func Recorder controlDEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF → Multi Screen OSDOSD ON/OFF Screen SELGO to Last PlayPause StopRecorder + If you select a recorder, and then press the Menu button Menu Flow WV-CU950/650If you press the Menu button without selecting a recorder If you select a recorder, and then press the Search buttonOperation Other than Terminal Mode PS·Data Mode OperationsConnections and Operations Controlling from a Web Browser Accessing a RecorderControlling from a PC Glossary Camera Access Refer to p Recorder Access Refer to pAlarm event Refer to p Monitor lock Refer to pPage Troubleshooting Matrix Switcher WJ-SX650 SeriesCoaxial communication RS-485 communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Power Cord, Connectors, and Power Plug Problem Check item and remedy ReferenceSpecifications Matrix Switcher WJ-SX650 SeriesVideo Output Board WJ-PB65M16 Card Cage WJ-SX650UVideo Input Board WJ-PB65C21 Sub/BNC Video Cable WJ-CA68 Standard AccessoriesExpansion Cable Kit WJ-CA65L20K/WJ-CA65L07K CD-ROMN0805-0 V8QA6300AN