Panasonic WJ-SX650 manual VD2/DATA/CABLE Compensation Menu, RS485 Camera Menu

Page 53

VD2/DATA/CABLE COMPENSATION Menu

530

VD2/DATA/CABLE COMPENSATION 1 of 2

 

INPUT BOARD=8

 

 

 

 

CAM

VD2

DATA

CABLE

CAM

VD2

DATA

CABLE

225

ON

 

OFF

S

233

ON

OFF

S

226

ON

OFF

M

234

ON

OFF

S

227

ON

OFF

L

235

ON

OFF

S

228

ON

OFF

S

236

ON

OFF

S

229

ON

OFF

M

237

ON

ON

S

230

ON

OFF

L

238

ON

ON

S

231

ON

OFF

S

239

ON

ON

S

232

ON

OFF

S

240

ON

ON

S

CAM=CAMERA

IN

 

 

 

 

DATA:CAMERA

CONTROL

SIGNAL

 

 

 

 

 

 

 

530

VD2/DATA/CABLE COMPENSATION 2 of 2

 

INPUT BOARD=8

 

 

 

 

CAM

VD2

DATA

CABLE

CAM

VD2

DATA

CABLE

241

ON

OFF

 

S

249

OFF

OFF

S

242

ON

OFF

M

250

OFF

OFF

S

243

OFF

OFF

L

251

OFF

OFF

S

244

OFF

OFF

S

252

OFF

OFF

S

245

OFF

OFF

M

253

OFF

OFF

S

246

OFF

OFF

L

254

OFF

OFF

S

247

OFF

OFF

S

255

OFF

OFF

S

248

OFF

OFF

S

256

OFF

OFF

S

CAM=CAMERA

IN

 

 

 

 

DATA:CAMERA

CONTROL

SIGNAL

 

 

 

 

 

 

 

 

 

 

 

 

• INPUT BOARD

Select a video input board from 1 to 8. (The factory default is 1.

• VD2

Select ON or OFF. (The factory default is ON.)

ON: Sends the VD2 timing pulse with the camera output signal.

OFF: Not sends the VD2 timing pulse with the camera out- put signal.

• DATA

Select ON or OFF. (The factory default is ON.)

ON: Sends the control data with the camera output signal.

OFF: Not sends the control data with the camera output signal

• CABLE

Perform the settings to compensate for the video signal transmission loss from the camera (cable compensation) according to the cable lengths. (The factory default is S.)

S:Less than 500 m

M:500 m to 900 m

L:900 m to 1 200 m

Note: When supplying video input signals from recorders or using cameras of other manufacturers, set DATA to OFF.

RS485 CAMERA Menu

540

RS485

CAMERA

 

 

 

 

1

of 2

 

INPUT

BOARD=8

 

 

 

 

 

CAM

RS485

ADR

 

CAM

RS485

 

ADR

225

 

29

 

1

 

233

30

 

1

226

29

 

2

 

234

30

 

2

227

29

 

3

 

235

30

 

3

228

29

 

4

 

236

30

 

4

229

29

 

5

 

237

 

 

 

230

29

 

6

 

238

 

 

 

231

29

 

7

 

239

 

 

 

232

29

 

8

 

240

 

 

 

COMMUNICATION

STATUS

19200/8/

NONE/1

CAM=CAMERA

IN

 

RS485=RS485(CAMERA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

540

RS485

CAMERA

 

 

 

 

2

of 2

 

INPUT

BOARD=8

 

 

 

 

 

CAM

RS485

ADR

 

CAM

RS485

 

ADR

241

 

31

 

1

 

249

 

 

 

242

32

 

1

 

250

 

 

 

243

 

 

 

 

 

 

251

 

 

 

244

 

 

 

 

 

 

252

 

 

 

245

 

 

 

 

 

 

253

 

 

 

246

 

 

 

 

 

 

254

 

 

 

247

 

 

 

 

 

 

255

 

 

 

248

 

 

 

 

 

 

256

 

 

 

COMMUNICATION

STATUS

19200/8/

NONE/1

CAM=CAMERA

IN

 

RS485=RS485(CAMERA)

 

 

 

 

 

 

 

 

 

 

 

• INPUT BOARD

Select a video input board from 1 to 8. (The factory default is 1.

• RS485

Select the RS-485 (CAMERA) port connecting RS-485 cam- eras. (The factory default is no settings.)

CAM001 to 032: 1 to 4 (INPUT BOARD=1)

CAM033 to 064: 5 to 8 (INPUT BOARD=2)

CAM065 to 096: 9 to 12 (INPUT BOARD=3)

CAM097 to 128: 13 to 16 (INPUT BOARD=4)

CAM129 to 160: 17 to 20 (INPUT BOARD=5)

CAM161 to 192: 21 to 24 (INPUT BOARD=6)

CAM193 to 224: 25 to 28 (INPUT BOARD=7)

CAM225 to 256: 29 to 32 (INPUT BOARD=8)

• ADR

Select the unit address for the connected RS-485 cameras.

Note: RS485 is not available for camera channels accept- ing video input signals from recorders. To activate RS- 485 camera connections, change the settings in RECORDER. (Refer to p. 87.)

53

Image 53
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Trademarks and Registered Trademarks Disclaimer of WarrantyLimitation of Liability Precautions Preparations pages xx, xx, xx About These Operating InstructionsAuthentication by user IDs, passwords, and level settings FeaturesTimer event and camera event can be scheduled Alarm operation and alarm event can be scheduledFront View WJ-SX650 Matrix Switcher/WJ-SX650U Card CageRear View 1Signal Ground Terminal Signal GNDA-3/IN B-3/IN C-3 board Video Input Board WJ-PB65C32X-2 board IN-3 boardOUT X-3 board Video Output Board WJ-PB65M16OUT X-2 board OUT X-1 boardMonitor Display Information WV-CU950/650 System Controller Display InformationCamera/recorder/sequence number 001 to 999 Camera number WV-CU360C/CJChecking Board Composition InstallationsSwitch Settings for Video Input Main Board Host Func Switch Settings for Video Output Main BoardFront view of video output main board Mounting Video Input and Output Boards Board Mounting Procedure Places to avoid Installing the Main UnitRack Mounting EIA equivalents Products of other manufacturers EIAStandards ConnectionsRecommended This unit x 1, camera x 30, monitor x 16, and recorder x Basic System ConnectionsThis unit x 3, camera x 150, monitor x 32, and recorder x Expanded System ConnectionsThis unit x 4, camera x 240, monitor x 32, and recorder x Line termination OFF Card Cage ConnectionsOFF Camera ConnectionsRS-485 Camera Connections WV-CA48/JN ConnectionDaisy Chain Connection PC Connection Monitor ConnectionsRecorders unit address Camera in channel Video input board Connection to Video Output Connectors of RecordersRecorder Connection Recorder number Unit Address System Video OUTConnection between Recorders and Video Input Boards OFF System Controller Connection Recorder SettingsTerminal Mode Connection Example PS·Data Mode ConnectionExternal Device Connections Alarm Sensor ConnectionsPin No Designation GNDTerminal Duration Remarks System Status CheckDisplay example of System Status MonitorSetup Menu Setup ProcedureRecorder 1 to 10 on Recorder 11 to 16 OFF Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation and Uninstallation WJ-SX650 Series Administrator ConsoleInstallation UninstallationStarting Up User Name admin Password sx650Window Details Tool BarReference No Explanation Tooltip Details2005 to 2099 Year ON, OFF, AUTO, B/W setting Display SystemCamera SequenceOperator AlarmSchedule Communication ControllerTop Menu Setup Menu OSDBasic Operations Year Alarm MenuMonth Day TimeRecorder Alarm Terminal Alarm MenuInput Board Data Port Menu System Menu800 bps/9 600 bps/19 200 bps/38 400 bps Data bit 8 bits Parity check None Stop bit 1 bitRS485 Camera Menu VD2/DATA/CABLE Compensation MenuVD2 RS485Information Operator Registration Login and LogoutOperation Start Login Power-on/offOperation Start/End Auto Login/Logout Operation End LogoutMonitor Lock Monitor ControlMonitor Selection Camera Control Preset Position ControlCamera Selection Camera Selection RecallAvailable buttons and functions F1 All home positions All Cameras ControlRecorder Control Recorder Selection Recorder Control EndRunning Sequence Group PresetDescriptions of Sequence Tour SequenceSetting item Parameter Remarks Sequence SettingTour Sequence Group Sequence/PresetSequence Stop Sequence PauseAvailable operations during sequence pause Sequence step forward/backwardTerminal alarm setting Alarm DescriptionsAlarm Occurrence Group Sequence/Preset Alarm ModesVideo Loss SpotAlarm Control Alarm Suspension Return to Alarm Mode StatusAlarm History Display Details on Alarm History DisplayREC Timer Event Timer DescriptionsCamera Event Auto TrackCleaning Alarm in Camera Not UseBW and Scene Patrols Scene PatrolsAlarm recover WV-CU950/650 Terminal Mode OperationLists of Operations and Functions Operation list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 Function list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV CU360C/CJALL Shift + SetupCAM ID EventShift + ALM ALL Reset Shift + ALL Reset ALM ResetALM Recall ACKCamera control Focus Near Focus FARFocus FAR + Focus NearWiper Shift + CAM Func Recorder controlDEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF OSD ON/OFF OSD→ Multi Screen Screen SELPause PlayGO to Last StopRecorder + If you press the Menu button without selecting a recorder Menu Flow WV-CU950/650If you select a recorder, and then press the Menu button If you select a recorder, and then press the Search buttonPS·Data Mode Operations Operation Other than Terminal ModeConnections and Operations Controlling from a Web Browser Accessing a RecorderControlling from a PC Alarm event Refer to p Camera Access Refer to p Recorder Access Refer to pGlossary Monitor lock Refer to pPage Matrix Switcher WJ-SX650 Series TroubleshootingRS-485 communication Coaxial communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Problem Check item and remedy Reference Power Cord, Connectors, and Power PlugMatrix Switcher WJ-SX650 Series SpecificationsVideo Output Board WJ-PB65M16 Card Cage WJ-SX650UVideo Input Board WJ-PB65C21 Expansion Cable Kit WJ-CA65L20K/WJ-CA65L07K Standard AccessoriesSub/BNC Video Cable WJ-CA68 CD-ROMN0805-0 V8QA6300AN