■Alarm Modes
The following alarm modes are available. (Alarm mode fol- lows the setting of "Display Mode".)
●Spot
The image of associated camera will be displayed on the monitor. Preset position or auxiliary control will be activated. The following alarm modes (=patterns to display alarm pic- tures on a monitor) are available. (Regardless of alarm modes, alarms occur to all the associated cameras.) The alarm mode setting is performed in "Alarm" – "Alarm Mode" of
SETUP MENU.
• Sequence mode
Alarm pictures are sequentially displayed on the associated monitor.
Alarm 1 | Alarm 2 |
Alarm 3 | Alarm 4 |
• Earliest mode
The earliest alarm picture is displayed on the associated monitor.
Alarm 1 |
• Latest mode
The latest alarm picture is displayed on the associated monitor.
Alarm 4 |
●Tour Sequence
Tour sequence is activated on the associated monitor.
●Group Sequence/Preset
Group sequence is activated on the associated monitors.
●OFF
Alarm information is displayed on the associated monitor, but alarm does not occur to monitors and cameras.
Notes:
•When a tour sequence, group sequence, or group pre- set is activated as an alarm event, the earlier alarm event on the monitor will be reset.
•When 33 or more alarms occur to a monitor, older alarms will be reset chronologically.
•After occurrence, the same alarm will be suspended for 5 seconds.
•By the alarm schedule setting, alarm events can be deactivated in the specified periods. The alarm sched- ule setting is performed in "Alarm" – "Alarm Event" of
■Video Loss
To display the video loss information on associated moni- tors and save the video loss history without making alarms occur to monitors and cameras, set "Display Mode" to OFF. Note: If Alarm A ("Display Mode" is OFF) occurs while Alarm B's ("Display Mode" is Spot, Tour Sequence or Group Sequence) are being activated, the Alarm A information will be displayed on the monitor after all
Alarm B's have been reset.