Panasonic WJ-SX650 Controlling from a Web Browser Accessing a Recorder, Controlling from a PC

Page 86

Connections of Matrix Switchers (WJ-SX650 Series) and a PS·Data System Controller

By setting the DATA ports of matrix switchers to PSD in SETUP MENU (refer to p. 90) and connecting a PS·Data system con- troller (CONTROLLER NO.: 1) to one of the ports, you can control these units from the system controller. (Refer to p. 69 for details on connections.)

By connecting a PS·Data system controller (CONTROLLER NO.: 1) to the DATA ports of the units with Cable Kit WV-CA48/10K, you can control these units from the system controller. (Refer to p. 69 for details on connections.)

Notes:

Connect Cable Kit to the DATA 1 port.

Set the DATA 1 port of each unit to PSD. (Refer to p. 90.)

Unit Address: 1

 

Unit Address: 2

 

Unit Address: 3

 

 

 

 

 

Matrix Switcher WJ-SX 650

Matrix Switcher WJ-SX 650

Matrix Switcher WJ-SX 650

Cable Kit

WV-CA48/10K

A B

1

2

3

4

5

6

7

8

9

 

0

 

CONTROLLER NO.: 1

Connections and Operations

When controlling two or more units from a PS·Data system controller, you need to select a unit before operation. Refer to WV-CU950/650 Operating Instructions for system unit selection.

The unit address of each unit must be different from that of system controller. The unit address settings are performed in "Communication" – "PS·Data" of WJ-SX650 Series Administrator Console.

When an alarm occurs to a unit, other units will accept the alarm as a serial alarm input.

User level settings for alarm suspension must be the same within all the units. If alarm suspension is restricted in the level setting of a unit, operators with the restricted levels cannot suspend even alarms occurring to other units.

The LCD settings are performed in "System" – "Logical Camera Number" of WJ-SX650 Series Administrator Console. Up to LCN 999 are available for the settings.

Controlling from a Web Browser Accessing a Recorder

If a recorder is connected to the unit, you can control cameras using a web browser installed on a PC accessing the recorder. You can set priority for web browser control. Priority setting is performed in "Operator" – "Operator" of WJ-SX650 Series Administrator Console.

Notes:

Refer to the operating instructions of recorder for details on browser control.

Regardless of priority setting, during the recorder control from a system controller, camera control is not available from a web browser accessing recorders connected to the same DATA port in the daisy chain.

Controlling from a PC

You can perform the operations and functions of system controllers by logging into the system and sending RS-232C com- mands from a PC connected to the unit. Refer to Serial (RS-232C) Connector Command Reference (PDF file on the supplied CD-ROM) for available commands.

86

Image 86
Contents Model Nos. WJ-SX650 Series English Version Important Safety Instructions Contents Trademarks and Registered Trademarks Disclaimer of WarrantyLimitation of Liability Precautions About These Operating Instructions Preparations pages xx, xx, xxTimer event and camera event can be scheduled FeaturesAuthentication by user IDs, passwords, and level settings Alarm operation and alarm event can be scheduledWJ-SX650 Matrix Switcher/WJ-SX650U Card Cage Front View1Signal Ground Terminal Signal GND Rear ViewX-2 board Video Input Board WJ-PB65C32A-3/IN B-3/IN C-3 board IN-3 boardOUT X-2 board Video Output Board WJ-PB65M16OUT X-3 board OUT X-1 boardMonitor Display Information System Controller Display Information WV-CU950/650WV-CU360C/CJ Camera/recorder/sequence number 001 to 999 Camera numberInstallations Checking Board CompositionSwitch Settings for Video Input Main Board Host Func Switch Settings for Video Output Main BoardFront view of video output main board Mounting Video Input and Output Boards Board Mounting Procedure Rack Mounting Installing the Main UnitPlaces to avoid EIA equivalents Products of other manufacturers EIAStandards ConnectionsRecommended Basic System Connections This unit x 1, camera x 30, monitor x 16, and recorder xExpanded System Connections This unit x 3, camera x 150, monitor x 32, and recorder xThis unit x 4, camera x 240, monitor x 32, and recorder x Card Cage Connections Line termination OFFOFF Camera ConnectionsRS-485 Camera Connections WV-CA48/JN ConnectionDaisy Chain Connection Monitor Connections PC ConnectionRecorders unit address Camera in channel Video input board Connection to Video Output Connectors of RecordersRecorder Connection Video OUT Recorder number Unit Address SystemConnection between Recorders and Video Input Boards OFF System Controller Connection Recorder SettingsTerminal Mode Connection PS·Data Mode Connection ExamplePin No Designation Alarm Sensor ConnectionsExternal Device Connections GNDDisplay example of System Status System Status CheckTerminal Duration Remarks MonitorRecorder 1 to 10 on Recorder 11 to 16 OFF Setup ProcedureSetup Menu Data 1, 2, 5 and 6 ports Tmnl Data 3, 4, 7 and 8 ports HDRSetup Menu Installation WJ-SX650 Series Administrator ConsoleInstallation and Uninstallation UninstallationWindow Details User Name admin Password sx650Starting Up Tool BarTooltip Details Reference No Explanation2005 to 2099 Year ON, OFF, AUTO, B/W setting Camera SystemDisplay SequenceOperator AlarmSchedule Controller CommunicationTop Menu Setup Menu OSDBasic Operations Month Alarm MenuYear Day TimeTerminal Alarm Menu Recorder AlarmInput Board 800 bps/9 600 bps/19 200 bps/38 400 bps System MenuData Port Menu Data bit 8 bits Parity check None Stop bit 1 bitVD2 VD2/DATA/CABLE Compensation MenuRS485 Camera Menu RS485Information Login and Logout Operator RegistrationOperation Start/End Auto Login/Logout Power-on/offOperation Start Login Operation End LogoutMonitor Lock Monitor ControlMonitor Selection Camera Selection Preset Position ControlCamera Control Camera Selection RecallAll Cameras Control Available buttons and functions F1 All home positionsRecorder Control Recorder Control End Recorder SelectionDescriptions of Sequence Group PresetRunning Sequence Tour SequenceSequence Setting Setting item Parameter RemarksGroup Sequence/Preset Tour SequenceAvailable operations during sequence pause Sequence PauseSequence Stop Sequence step forward/backwardTerminal alarm setting Alarm DescriptionsAlarm Occurrence Video Loss Alarm ModesGroup Sequence/Preset SpotAlarm Control Alarm History Display Return to Alarm Mode StatusAlarm Suspension Details on Alarm History DisplayREC Camera Event Timer DescriptionsTimer Event Auto TrackBW and Scene Patrols Alarm in Camera Not UseCleaning Scene PatrolsLists of Operations and Functions Terminal Mode OperationAlarm recover WV-CU950/650 Operation list of WV-CU950/650 and WV-CU360C/CJWV-CU950/650, WV Function list of WV-CU950/650 and WV-CU360C/CJFunction WV-CU950/650 CU360C/CJCAM ID Shift + SetupALL EventALM Recall ALM ResetShift + ALM ALL Reset Shift + ALL Reset ACKCamera control Focus FAR + Focus Focus FARFocus Near NearWiper Shift + CAM Func Recorder controlDEF on Shift + DEF on OFF DEF OFF Shift + DEF OFF → Multi Screen OSDOSD ON/OFF Screen SELGO to Last PlayPause StopRecorder + If you select a recorder, and then press the Menu button Menu Flow WV-CU950/650If you press the Menu button without selecting a recorder If you select a recorder, and then press the Search buttonOperation Other than Terminal Mode PS·Data Mode OperationsConnections and Operations Controlling from a Web Browser Accessing a RecorderControlling from a PC Glossary Camera Access Refer to p Recorder Access Refer to pAlarm event Refer to p Monitor lock Refer to pPage Troubleshooting Matrix Switcher WJ-SX650 SeriesCoaxial communication RS-485 communicationProblem Check item and remedy Check if the alarm event has been set WJ-SX650 Series Administrator Console Power Cord, Connectors, and Power Plug Problem Check item and remedy ReferenceSpecifications Matrix Switcher WJ-SX650 SeriesVideo Output Board WJ-PB65M16 Card Cage WJ-SX650UVideo Input Board WJ-PB65C21 Sub/BNC Video Cable WJ-CA68 Standard AccessoriesExpansion Cable Kit WJ-CA65L20K/WJ-CA65L07K CD-ROMN0805-0 V8QA6300AN